[Evaluation of the reproducibility of automated monocyte counting using flow cytometry and monoclonal antibodies]. 1994

J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
Servei d'Hematologia Biològica, Hospital Clínic i Provincial, Universitat de Barcelona.

OBJECTIVE To compare the results of the monocyte count provided by autoanalysers with those attained with flow cytometry. METHODS Fifty-six blood samples (EDTA-K3) from the emergency laboratory were studied. The automatic percentage of monocytes attained by four autoanalysers, STKS (Coulter-IZASA), Technicon H*2 (Bayer Diagnostics), Cell-Dyn-3000 (Abbott Diagnostics) and NE-8000 (TOA-Sysmex) was confronted with that provided by the flow cytometry analysis performed with a FACScan (Becton-Dickinson) using monoclonal antibodies of myeloid-monocytic lineage (CD14, CD16). The morphologic observation of the blood smear in accordance with the H20-A protocol of the National Committee for Clinical Laboratory Standards (NCCLS) was used as a reference method. Descriptive statistics plus linear regression analysis, along with the Student's t test for paired data were used for the statistical evaluation of the results. RESULTS Significant correlation was found between the systems under study and the flow cytometry method: Technicon H*2 (y = 1.79 +/- 0.61x; r = 0.91, p < 0.0001), Coulter STKS (y = 0.61 +/- 0.93X; r = 0.89, p < 0.0001), Cell-Dyn 3000 (y = 0.88 + 0.64x; r = 0.78, p < 0.0001) and Sysmex NE-8000 (y = 4.60 +/- 0.33x; r = 0.52, p < 0.0001). When comparing the percentage of monocytes by means of the Student's t test it was found that Coulter STKS provided the closest results with regard to flow cytometry (13.78 +/- 9.27 vs 14.19 +/- 8.88, p = 0.49), while the closest findings with respect to the reference method were given by Technicon H*2 (9.29 +/- 4.78 vs 9.71 +/- 4.77, p = 0.30). CONCLUSIONS From this analysis, it was concluded that flow cytometry could be an alternative method to conventional optic observation in the evaluation of the differential count of leucocytes, including monocytes.

UI MeSH Term Description Entries
D007958 Leukocyte Count The number of WHITE BLOOD CELLS per unit volume in venous BLOOD. A differential leukocyte count measures the relative numbers of the different types of white cells. Blood Cell Count, White,Differential Leukocyte Count,Leukocyte Count, Differential,Leukocyte Number,White Blood Cell Count,Count, Differential Leukocyte,Count, Leukocyte,Counts, Differential Leukocyte,Counts, Leukocyte,Differential Leukocyte Counts,Leukocyte Counts,Leukocyte Counts, Differential,Leukocyte Numbers,Number, Leukocyte,Numbers, Leukocyte
D009000 Monocytes Large, phagocytic mononuclear leukocytes produced in the vertebrate BONE MARROW and released into the BLOOD; contain a large, oval or somewhat indented nucleus surrounded by voluminous cytoplasm and numerous organelles. Monocyte
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000911 Antibodies, Monoclonal Antibodies produced by a single clone of cells. Monoclonal Antibodies,Monoclonal Antibody,Antibody, Monoclonal
D001322 Autoanalysis Method of analyzing chemicals using automation. Autoanalyses
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D016130 Immunophenotyping Process of classifying cells of the immune system based on structural and functional differences. The process is commonly used to analyze and sort T-lymphocytes into subsets based on CD antigens by the technique of flow cytometry. Lymphocyte Immunophenotyping,Lymphocyte Subtyping,Immunologic Subtyping,Immunologic Subtypings,Lymphocyte Phenotyping,Subtyping, Immunologic,Subtypings, Immunologic,Immunophenotyping, Lymphocyte,Immunophenotypings,Immunophenotypings, Lymphocyte,Lymphocyte Immunophenotypings,Lymphocyte Phenotypings,Lymphocyte Subtypings,Phenotyping, Lymphocyte,Phenotypings, Lymphocyte,Subtyping, Lymphocyte,Subtypings, Lymphocyte

Related Publications

J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
April 2005, Clinical and laboratory haematology,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
October 2018, International journal of laboratory hematology,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
January 1996, Journal of clinical laboratory analysis,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
January 1996, Transfusion clinique et biologique : journal de la Societe francaise de transfusion sanguine,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
August 1990, Journal of clinical pathology,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
March 2012, Cytometry. Part B, Clinical cytometry,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
January 1993, Schweizerische medizinische Wochenschrift,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
March 1996, Cytometry,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
April 1999, Hematology and cell therapy,
J L Vives Corrons, and I Besson, and N Villamor, and M Aymerich, and J L Marín, and J M Jou
December 2022, Antibodies (Basel, Switzerland),
Copied contents to your clipboard!