Cemented revision Charnley low-friction arthroplasty in patients with rheumatoid arthritis. 1994

V V Raut, and P D Siney, and B M Wroblewski
Wrightington Hospital for Joint Disease, Wigan, England.

We assessed 41 patients with rheumatoid arthritis (47 hips) who had had revision hip arthroplasty, at an average follow-up of 7 years 4 months (2 to 19). The clinical results were excellent or satisfactory in 43 hips. Radiologically, 45 stems were secure. Fifteen sockets (36.6%) were radiologically loose. Three hips required rerevision. Socket failure is the predominant problem in rheumatoid patients after cemented revision arthroplasty.

UI MeSH Term Description Entries
D007593 Joint Instability Lack of stability of a joint or joint prosthesis. Hypermobility, Joint,Instability, Joint,Laxity, Joint,Hypermobilities, Joint,Instabilities, Joint,Joint Hypermobilities,Joint Hypermobility,Joint Instabilities,Joint Laxities,Joint Laxity,Laxities, Joint
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D011859 Radiography Examination of any part of the body for diagnostic purposes by means of X-RAYS or GAMMA RAYS, recording the image on a sensitized surface (such as photographic film). Radiology, Diagnostic X-Ray,Roentgenography,X-Ray, Diagnostic,Diagnostic X-Ray,Diagnostic X-Ray Radiology,X-Ray Radiology, Diagnostic,Diagnostic X Ray,Diagnostic X Ray Radiology,Diagnostic X-Rays,Radiology, Diagnostic X Ray,X Ray Radiology, Diagnostic,X Ray, Diagnostic,X-Rays, Diagnostic
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D001843 Bone Cements Adhesives used to fix prosthetic devices to bones and to cement bone to bone in difficult fractures. Synthetic resins are commonly used as cements. A mixture of monocalcium phosphate, monohydrate, alpha-tricalcium phosphate, and calcium carbonate with a sodium phosphate solution is also a useful bone paste. Bone Cement,Bone Glues,Bone Pastes,Bone Glue,Bone Paste,Cement, Bone,Cements, Bone,Glue, Bone,Glues, Bone,Paste, Bone,Pastes, Bone
D005260 Female Females
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006621 Hip Joint The joint that is formed by the articulation of the head of FEMUR and the ACETABULUM of the PELVIS. Acetabulofemoral Joint,Acetabulofemoral Joints,Hip Joints,Joint, Acetabulofemoral,Joint, Hip,Joints, Acetabulofemoral,Joints, Hip

Related Publications

V V Raut, and P D Siney, and B M Wroblewski
June 1983, Clinical orthopaedics and related research,
V V Raut, and P D Siney, and B M Wroblewski
November 1983, The Journal of bone and joint surgery. British volume,
V V Raut, and P D Siney, and B M Wroblewski
February 1998, The Journal of arthroplasty,
V V Raut, and P D Siney, and B M Wroblewski
October 1986, Clinical orthopaedics and related research,
V V Raut, and P D Siney, and B M Wroblewski
January 1981, The Journal of bone and joint surgery. British volume,
V V Raut, and P D Siney, and B M Wroblewski
September 1999, The Journal of arthroplasty,
V V Raut, and P D Siney, and B M Wroblewski
September 1989, Clinical orthopaedics and related research,
V V Raut, and P D Siney, and B M Wroblewski
April 2010, The Journal of bone and joint surgery. British volume,
Copied contents to your clipboard!