Flow-synchronized ventilation of preterm infants with respiratory distress syndrome. 1994

S M Donn, and J J Nicks, and M A Becker
Department of Pediatrics, University of Michigan Medical Center, Ann Arbor.

Asynchrony of delivered and spontaneous breaths in mechanically ventilated infants may impair gas exchange and prolong the need for assisted ventilation. We conducted a randomized, controlled trial of a patient-triggered, flow-synchronized ventilator on 30 preterm infants with respiratory distress syndrome who weighed between 1100 and 1500 gm at birth. Entry criteria included radiographic evidence of respiratory distress syndrome and the need for mechanical ventilation and surfactant replacement therapy. Patients were assigned to either conventional time-cycled, pressure-limited ventilation or patient-triggered, flow-synchronized ventilation in an assist/control mode. Otherwise clinical management was identical. Time to extubation was the primary outcome measure. Patients treated with flow-synchronized ventilation were weaned more rapidly and had a significantly shorter mean time to extubation than those treated with time-cycled, pressure-limited ventilation, 119 versus 271 hours, p = 0.0152. In addition, there was no difference in the rate of complications between the two groups. There were, however, considerable reductions in patient charges of $4344 per patient in the flow-synchronized ventilation group.

UI MeSH Term Description Entries
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D007235 Infant, Premature, Diseases Diseases that occur in PREMATURE INFANTS.
D008297 Male Males
D012119 Respiration The act of breathing with the LUNGS, consisting of INHALATION, or the taking into the lungs of the ambient air, and of EXHALATION, or the expelling of the modified air which contains more CARBON DIOXIDE than the air taken in (Blakiston's Gould Medical Dictionary, 4th ed.). This does not include tissue respiration ( Breathing
D012121 Respiration, Artificial Any method of artificial breathing that employs mechanical or non-mechanical means to force the air into and out of the lungs. Artificial respiration or ventilation is used in individuals who have stopped breathing or have RESPIRATORY INSUFFICIENCY to increase their intake of oxygen (O2) and excretion of carbon dioxide (CO2). Ventilation, Mechanical,Mechanical Ventilation,Artificial Respiration,Artificial Respirations,Mechanical Ventilations,Respirations, Artificial,Ventilations, Mechanical
D012127 Respiratory Distress Syndrome, Newborn A condition of the newborn marked by DYSPNEA with CYANOSIS, heralded by such prodromal signs as dilatation of the alae nasi, expiratory grunt, and retraction of the suprasternal notch or costal margins, mostly frequently occurring in premature infants, children of diabetic mothers, and infants delivered by cesarean section, and sometimes with no apparent predisposing cause. Infantile Respiratory Distress Syndrome,Neonatal Respiratory Distress Syndrome,Respiratory Distress Syndrome, Infant
D012129 Respiratory Function Tests Measurement of the various processes involved in the act of respiration: inspiration, expiration, oxygen and carbon dioxide exchange, lung volume and compliance, etc. Lung Function Tests,Pulmonary Function Tests,Function Test, Pulmonary,Function Tests, Pulmonary,Pulmonary Function Test,Test, Pulmonary Function,Tests, Pulmonary Function,Function Test, Lung,Function Test, Respiratory,Function Tests, Lung,Function Tests, Respiratory,Lung Function Test,Respiratory Function Test,Test, Lung Function,Test, Respiratory Function,Tests, Lung Function,Tests, Respiratory Function
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015300 Ventilator Weaning Techniques for effecting the transition of the respiratory-failure patient from mechanical ventilation to spontaneous ventilation, while meeting the criteria that tidal volume be above a given threshold (greater than 5 ml/kg), respiratory frequency be below a given count (less than 30 breaths/min), and oxygen partial pressure be above a given threshold (PaO2 greater than 50mm Hg). Weaning studies focus on finding methods to monitor and predict the outcome of mechanical ventilator weaning as well as finding ventilatory support techniques which will facilitate successful weaning. Present methods include intermittent mandatory ventilation, intermittent positive pressure ventilation, and mandatory minute volume ventilation. Mechanical Ventilator Weaning,Respirator Weaning,Ventilator Weaning, Mechanical,Weaning, Mechanical Ventilator,Weaning, Respirator,Weaning, Ventilator

Related Publications

S M Donn, and J J Nicks, and M A Becker
November 2014, Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics,
S M Donn, and J J Nicks, and M A Becker
February 1997, Anales espanoles de pediatria,
S M Donn, and J J Nicks, and M A Becker
July 2010, Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics,
S M Donn, and J J Nicks, and M A Becker
November 1990, The Journal of pediatrics,
S M Donn, and J J Nicks, and M A Becker
January 1999, Archives of disease in childhood. Fetal and neonatal edition,
S M Donn, and J J Nicks, and M A Becker
March 2013, The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians,
S M Donn, and J J Nicks, and M A Becker
January 2000, The Cochrane database of systematic reviews,
Copied contents to your clipboard!