[Pressure build-up in 2 rate-controlled syringe infusion pumps]. 1994

C Gerlif
Kolding Sygehus, anaestesiafdelingen.

The use of rate controlled syringe infusion pumps has spread to departments where the need for accurate infusion exists. The simplicity in using these pumps has led to a false feeling of safety. A case of hazardous use of a syringe infusion pump has been reviewed. An Ohmeda 9000- and a Terumo STC 521 syringe pump was here tested, n = 20. The occlusion pressures of the two pumps were different. The occlusion pressure changed with different infusion rates for both pumps. The pressure was built up in a straight linear fashion. The bolus release depended on the occlusion pressure and the amounts given were in the range of 1.0-1.6 ml, both pumps included. The time from occlusion to alarm depended on the occlusion pressures. There might be an advantage in using a soft infusion system. It is recommended not to use syringe pump infusion via peripheral veins so as to avoid the risk of pressure build-up in the subcutaneous tissue in case of infiltration. In the event of occlusion disconnect the infusion system prior to reopening. Don't rely on the occlusion alarm. Use a smooth infusion system.

UI MeSH Term Description Entries
D007260 Infusion Pumps Fluid propulsion systems driven mechanically, electrically, or osmotically that are used to inject (or infuse) over time agents into a patient or experimental animal; used routinely in hospitals to maintain a patent intravenous line, to administer antineoplastic agents and other drugs in thromboembolism, heart disease, diabetes mellitus (INSULIN INFUSION SYSTEMS is also available), and other disorders. Drug Infusion Systems,Infusion Pump,Infusion Pumps, External,Infusors,Intravenous Drug Delivery System,Intravenous Drug Delivery Systems,Perfusion Pumps,Pumps, Infusion,Drug Infusion System,External Infusion Pump,External Infusion Pumps,Infusion Pump, External,Infusion System, Drug,Infusion Systems, Drug,Infusor,Perfusion Pump,Pump, External Infusion,Pump, Infusion,Pump, Perfusion,Pumps, External Infusion,Pumps, Perfusion,System, Drug Infusion,Systems, Drug Infusion
D011312 Pressure A type of stress exerted uniformly in all directions. Its measure is the force exerted per unit area. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Pressures
D002675 Child, Preschool A child between the ages of 2 and 5. Children, Preschool,Preschool Child,Preschool Children
D004487 Edema Abnormal fluid accumulation in TISSUES or body cavities. Most cases of edema are present under the SKIN in SUBCUTANEOUS TISSUE. Dropsy,Hydrops,Anasarca
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D004869 Equipment Safety Freedom of equipment from actual or potential hazards. Device Safety,Hazards, Equipment,Medical Device Safety,Safety, Equipment,Device Safety, Medical,Safety, Medical Device,Equipment Hazard,Equipment Hazards,Hazard, Equipment,Safety, Device
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012307 Risk Factors An aspect of personal behavior or lifestyle, environmental exposure, inborn or inherited characteristic, which, based on epidemiological evidence, is known to be associated with a health-related condition considered important to prevent. Health Correlates,Risk Factor Scores,Risk Scores,Social Risk Factors,Population at Risk,Populations at Risk,Correlates, Health,Factor, Risk,Factor, Social Risk,Factors, Social Risk,Risk Factor,Risk Factor Score,Risk Factor, Social,Risk Factors, Social,Risk Score,Score, Risk,Score, Risk Factor,Social Risk Factor
D013594 Syringes Instruments used for injecting or withdrawing fluids. (Stedman, 25th ed) Hypodermic Syringes,Syringe, Karman,Hypodermic Syringe,Karman Syringe,Syringe,Syringe, Hypodermic,Syringes, Hypodermic

Related Publications

C Gerlif
January 2001, Paediatric anaesthesia,
C Gerlif
December 1995, Pediatric emergency care,
C Gerlif
September 1988, Drug intelligence & clinical pharmacy,
C Gerlif
July 2009, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation,
C Gerlif
September 2011, Anaesthesia and intensive care,
C Gerlif
March 1991, Anesthesia and analgesia,
Copied contents to your clipboard!