Measurement of transcutaneous carbon dioxide in low birthweight infants during the first two weeks of life. 1994

N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
Department of Respiratory Care, University of Cincinnati, Ohio.

With the advent of pulse oximetry, there has been a general decrease in the use of transcutaneous (Tc) blood gas monitoring in intensive care environments. The available data, however, suggest that arterial carbon dioxide pressure (PCO2) levels are best estimated by Tc methods. In this study, we report our experience using routine Tc PCO2 monitoring in 32 consecutive infants less than 2 weeks of age with birthweights less than 1500 g. A total of 644 simultaneous pairs (Tc PCO2 versus arterial PCO2) were obtained. Pairs were categorized according to a 2 x 2 matrix design based on sensor temperature (40 degrees or 43 degrees C) versus site of arterial sampling (umbilical [UAC] or peripheral artery catheter [PAC]). Sampling via the UAC resulted in excellent correlation between sample pairs at both sensor temperatures with similar regressions between groups. Sampling via the PAC, however, yielded poor correlation between sample pairs and a significantly different regression from both UAC groups. Based on these findings, we advocate the use of a sensor temperature of 40 degrees C in very low birthweight infants for tracking Tc PCO2 values. In addition, we suggest that inaccuracies in PAC sampling may lead to erroneous PCO2 determinations. We conclude that routine monitoring of Tc PCO2 is accurate and serves a useful and continuing role in the neonatal intensive care environment.

UI MeSH Term Description Entries
D007230 Infant, Low Birth Weight An infant having a birth weight of 2500 gm. (5.5 lb.) or less but INFANT, VERY LOW BIRTH WEIGHT is available for infants having a birth weight of 1500 grams (3.3 lb.) or less. Low Birth Weight,Low-Birth-Weight Infant,Birth Weight, Low,Birth Weights, Low,Infant, Low-Birth-Weight,Infants, Low-Birth-Weight,Low Birth Weight Infant,Low Birth Weights,Low-Birth-Weight Infants
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D007363 Intensive Care Units, Neonatal Hospital units providing continuing surveillance and care to acutely ill newborn infants. Neonatal Intensive Care Unit,Neonatal Intensive Care Units,Newborn Intensive Care Unit,Newborn Intensive Care Units,ICU, Neonatal,Neonatal ICU,Newborn ICU,Newborn Intensive Care Units (NICU),ICU, Newborn,ICUs, Neonatal,ICUs, Newborn,Neonatal ICUs,Newborn ICUs
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D001785 Blood Gas Monitoring, Transcutaneous The noninvasive measurement or determination of the partial pressure (tension) of oxygen and/or carbon dioxide locally in the capillaries of a tissue by the application to the skin of a special set of electrodes. These electrodes contain photoelectric sensors capable of picking up the specific wavelengths of radiation emitted by oxygenated versus reduced hemoglobin. Carbon Dioxide Partial Pressure Determination, Transcutaneous,Cutaneous Oximetry,Oximetry, Transcutaneous,Oxygen Partial Pressure Determination, Transcutaneous,Transcutaneous Blood Gas Monitoring,Transcutaneous Capnometry,Transcutaneous Oximetry,PtcO2,TcPCO2,Capnometries, Transcutaneous,Capnometry, Transcutaneous,Cutaneous Oximetries,Oximetries, Cutaneous,Oximetries, Transcutaneous,Oximetry, Cutaneous,Transcutaneous Capnometries,Transcutaneous Oximetries
D002245 Carbon Dioxide A colorless, odorless gas that can be formed by the body and is necessary for the respiration cycle of plants and animals. Carbonic Anhydride,Anhydride, Carbonic,Dioxide, Carbon
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001158 Arteries The vessels carrying blood away from the heart. Artery

Related Publications

N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
October 2017, Experimental dermatology,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
January 2016, Critical care research and practice,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
January 1987, Journal of perinatal medicine,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
June 1993, Journal of developmental and behavioral pediatrics : JDBP,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
January 1992, Pediatric research,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
December 1984, Archives of disease in childhood,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
September 1993, Clinical pharmacology and therapeutics,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
October 1986, Archives francaises de pediatrie,
N Binder, and H Atherton, and T Thorkelsson, and S B Hoath
January 1983, JPEN. Journal of parenteral and enteral nutrition,
Copied contents to your clipboard!