The selection of electromyographic needle electrodes. 1994

R L Joynt
Department of Physical Medicine and Rehabilitation, Wayne State University, Detroit, MI.

Monopolar and concentric reusable and disposable EMG needle electrodes from several manufacturers were studied at various stages of usage. Needle tips were examined and measured microscopically, and needles were tested for spontaneous noise and resistive and capacitative characteristics at four different test signal frequencies. Resistive and capacitative characteristics were found to be frequency dependent. Needle tip areas differed by as much as 10 times among the various electrodes. The amount of noise correlated most highly with resistive characteristics. Monopolar and concentric needles differed in respect to tip area, noise, and all resistive and capacitative measures. Coaxial disposable and reusable electrodes did not differ significantly and minor differences were noted in electrical characteristics between reusable and disposable monopolar needles, even from the same manufacturer. There was considerable variability among manufacturers for both needle types. In choosing an electrode, consistent tip area is probably the most important consideration to ensure repeatable quantifiable results, but minimizing needle impedance is useful to reduce noise.

UI MeSH Term Description Entries
D008422 Materials Testing The testing of materials and devices, especially those used for PROSTHESES AND IMPLANTS; SUTURES; TISSUE ADHESIVES; etc., for hardness, strength, durability, safety, efficacy, and biocompatibility. Biocompatibility Testing,Biocompatible Materials Testing,Hemocompatibility Testing,Testing, Biocompatible Materials,Testing, Hemocompatible Materials,Hemocompatibility Testings,Hemocompatible Materials Testing,Materials Testing, Biocompatible,Materials Testing, Hemocompatible,Testing, Biocompatibility,Testing, Hemocompatibility,Testing, Materials,Testings, Biocompatibility
D009339 Needles Sharp instruments used for puncturing or suturing. Hypodermic Needles,Hypodermic Needle,Needle,Needle, Hypodermic,Needles, Hypodermic
D004209 Disposable Equipment Apparatus, devices, or supplies intended for one-time or temporary use. Equipment, Disposable
D004389 Durable Medical Equipment Devices which are very resistant to wear and may be used over a long period of time. They include items such as wheelchairs, hospital beds, artificial limbs, etc. Equipment, Medical, Durable,Equipment, Durable Medical,Medical Equipment, Durable
D004553 Electric Conductivity The ability of a substrate to allow the passage of ELECTRONS. Electrical Conductivity,Conductivity, Electric,Conductivity, Electrical
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D004576 Electromyography Recording of the changes in electric potential of muscle by means of surface or needle electrodes. Electromyogram,Surface Electromyography,Electromyograms,Electromyographies,Electromyographies, Surface,Electromyography, Surface,Surface Electromyographies
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D012815 Signal Processing, Computer-Assisted Computer-assisted processing of electric, ultrasonic, or electronic signals to interpret function and activity. Digital Signal Processing,Signal Interpretation, Computer-Assisted,Signal Processing, Digital,Computer-Assisted Signal Interpretation,Computer-Assisted Signal Interpretations,Computer-Assisted Signal Processing,Interpretation, Computer-Assisted Signal,Interpretations, Computer-Assisted Signal,Signal Interpretation, Computer Assisted,Signal Interpretations, Computer-Assisted,Signal Processing, Computer Assisted
D016477 Artifacts Any visible result of a procedure which is caused by the procedure itself and not by the entity being analyzed. Common examples include histological structures introduced by tissue processing, radiographic images of structures that are not naturally present in living tissue, and products of chemical reactions that occur during analysis. Artefacts,Artefact,Artifact

Related Publications

R L Joynt
January 1961, Deutsche Zeitschrift fur Nervenheilkunde,
R L Joynt
October 2021, Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology,
R L Joynt
December 1994, Electromyography and clinical neurophysiology,
R L Joynt
January 1959, Technical bulletin of the Registry of Medical Technologists. American Society of Clinical Pathologists. Registry of Medical Technologists,
R L Joynt
January 1972, Acta biologica et medica Germanica,
R L Joynt
January 1973, Advances in experimental medicine and biology,
R L Joynt
January 1973, Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete,
Copied contents to your clipboard!