Potential glucose sensor for perioperative blood glucose control in diabetes mellitus. 1994

K R Greenough, and A W Skillen, and C J McNeil
Department of Clinical Biochemistry, Medical School, University of Newcastle upon Tyne, UK.

A glucose sensor intended for future use in diabetic patients undergoing major surgery is described. It involves glucose oxidase immobilised at a platinised activated carbon electrode (PACE). The sensor gave a nonoxygen dependent amperometric response in whole undiluted blood and did not require the use of electron mediators. In vitro studies in protein containing buffer using a flow cell indicated current densities of approximately 160 nA mm-2 mM-1 and a linear response over the range 0-20 mM. The operational stability of the sensor was at least 49 h in continuous use. In addition the sensor had a 90-99% response time of 1 min when used at a flow rate of 3 ml min-1 and showed a temperature dependence of 2.4% C-1. The results reported suggest significant advantages of this approach, for future use as a perioperative intra-vascular sensor for diabetic subjects, over previously reported glucose sensors.

UI MeSH Term Description Entries
D001786 Blood Glucose Glucose in blood. Blood Sugar,Glucose, Blood,Sugar, Blood
D003920 Diabetes Mellitus A heterogeneous group of disorders characterized by HYPERGLYCEMIA and GLUCOSE INTOLERANCE.
D004795 Enzyme Stability The extent to which an enzyme retains its structural conformation or its activity when subjected to storage, isolation, and purification or various other physical or chemical manipulations, including proteolytic enzymes and heat. Enzyme Stabilities,Stabilities, Enzyme,Stability, Enzyme
D005949 Glucose Oxidase An enzyme of the oxidoreductase class that catalyzes the conversion of beta-D-glucose and oxygen to D-glucono-1,5-lactone and peroxide. It is a flavoprotein, highly specific for beta-D-glucose. The enzyme is produced by Penicillium notatum and other fungi and has antibacterial activity in the presence of glucose and oxygen. It is used to estimate glucose concentration in blood or urine samples through the formation of colored dyes by the hydrogen peroxide produced in the reaction. (From Enzyme Nomenclature, 1992) EC 1.1.3.4. Microcid,Oxidase, Glucose
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015374 Biosensing Techniques Any of a variety of procedures which use biomolecular probes to measure the presence or concentration of biological molecules, biological structures, microorganisms, etc., by translating a biochemical interaction at the probe surface into a quantifiable physical signal. Bioprobes,Biosensors,Electrodes, Enzyme,Biosensing Technics,Bioprobe,Biosensing Technic,Biosensing Technique,Biosensor,Electrode, Enzyme,Enzyme Electrode,Enzyme Electrodes,Technic, Biosensing,Technics, Biosensing,Technique, Biosensing,Techniques, Biosensing
D016014 Linear Models Statistical models in which the value of a parameter for a given value of a factor is assumed to be equal to a + bx, where a and b are constants. The models predict a linear regression. Linear Regression,Log-Linear Models,Models, Linear,Linear Model,Linear Regressions,Log Linear Models,Log-Linear Model,Model, Linear,Model, Log-Linear,Models, Log-Linear,Regression, Linear,Regressions, Linear
D016343 Monitoring, Intraoperative The constant checking on the state or condition of a patient during the course of a surgical operation (e.g., checking of vital signs). Intraoperative Monitoring

Related Publications

K R Greenough, and A W Skillen, and C J McNeil
September 2015, Masui. The Japanese journal of anesthesiology,
K R Greenough, and A W Skillen, and C J McNeil
May 2008, Praxis,
K R Greenough, and A W Skillen, and C J McNeil
January 1980, Acta medica Scandinavica,
K R Greenough, and A W Skillen, and C J McNeil
November 2012, Masui. The Japanese journal of anesthesiology,
K R Greenough, and A W Skillen, and C J McNeil
June 2012, Zhonghua wei chang wai ke za zhi = Chinese journal of gastrointestinal surgery,
K R Greenough, and A W Skillen, and C J McNeil
April 1994, Zeitschrift fur arztliche Fortbildung,
K R Greenough, and A W Skillen, and C J McNeil
January 1991, Diabetic medicine : a journal of the British Diabetic Association,
K R Greenough, and A W Skillen, and C J McNeil
January 2000, American journal of medical quality : the official journal of the American College of Medical Quality,
K R Greenough, and A W Skillen, and C J McNeil
December 1993, Diabetes care,
K R Greenough, and A W Skillen, and C J McNeil
February 2009, Nederlands tijdschrift voor geneeskunde,
Copied contents to your clipboard!