[Intravenous administration of anti-D hyperimmunoglobulin after mismatched transfusion (author's transl)]. 1976

A Wegmann, and H Hübner, and H Erb

620 ml of 0 Rh-positive blood (310 ml CCD.ee + 310 ml CcD.EE) were administered to a 27-year-old 0 Rh-negative (ccddee) woman in connection with an emergency curettage. 16 hours after this mismatched transfusion an intravenous infusion of anti-D hyperimmunoglobulin was started: 8000 mug (13 mug/ml blood) were given within 14 hours (570 mug/h) under strict supervision. The 10% immunoglobulin preparation had been diluted 20 times. There were only slight variations in heart rate and blood pressure, slight fever and mild increase in serum bilirubin after the infusion. There was slight haemoglobinuria in one urine sample, but no signs of kidney damage. The direct Coombs test was slightly positive after two days, negative after four and six days. The indirect Coombs test was negative after six months. The patient has not become pregnant since. Slow intravenous infusion of highly diluted anti-D hyperimmunoglobulin, under strict clinical supervision, is probably appropriate for Rh prophylaxis after transfusion mismatch. The dose of 13 mug/ml could probably be considerably reduced. 250 mug anti-D per hour should not be exceeded.

UI MeSH Term Description Entries
D007049 Iatrogenic Disease Any adverse condition in a patient occurring as the result of treatment by a physician, surgeon, or other health professional, especially infections acquired by a patient during the course of treatment. Hospital-Acquired Condition,Condition, Hospital-Acquired,Conditions, Hospital-Acquired,Disease, Iatrogenic,Diseases, Iatrogenic,Hospital Acquired Condition,Hospital-Acquired Conditions,Iatrogenic Diseases
D007275 Injections, Intravenous Injections made into a vein for therapeutic or experimental purposes. Intravenous Injections,Injection, Intravenous,Intravenous Injection
D008508 Medication Errors Errors in prescribing, dispensing, or administering medication with the result that the patient fails to receive the correct drug or the indicated proper drug dosage. Drug Use Error,Errors, Medication,High-Alert Drug Error,High-Alert Medication Error,LASA Medication Errors,Look-Alike Drug Name Errors,Look-Alike Sound-Alike Drug Errors,Look-Alike Sound-Alike Drug Substitution Errors,Look-Alike Sound-Alike Medication Errors,Lookalike Drug Name Errors,Lookalike Soundalike Drug Errors,Lookalike Soundalike Drug Substitution Errors,Lookalike Soundalike Medication Errors,Drug Error, High-Alert,Drug Use Errors,Error, Drug Use,Error, LASA Medication,Error, Medication,High Alert Drug Error,High Alert Medication Error,High-Alert Drug Errors,High-Alert Medication Errors,LASA Medication Error,Look Alike Drug Name Errors,Look Alike Sound Alike Drug Errors,Look Alike Sound Alike Drug Substitution Errors,Look Alike Sound Alike Medication Errors,Medication Error,Medication Error, High-Alert,Medication Error, LASA,Medication Errors, High-Alert,Medication Errors, LASA
D001787 Blood Group Incompatibility An antigenic mismatch between donor and recipient blood. Antibodies present in the recipient's serum may be directed against antigens in the donor product. Such a mismatch may result in a transfusion reaction in which, for example, donor blood is hemolyzed. (From Saunders Dictionary & Encyclopedia of Laboratory Medicine and Technology, 1984). ABO Compatibility,ABO Incompatibility,Blood Group ABO Incompatibility,Blood Type Incompatibility,Rh Compatibility,Rh Incompatibility,ABO Compatibilities,ABO Incompatibilities,Blood Group Incompatibilities,Blood Type Incompatibilities,Compatibility, ABO,Compatibility, Rh,Incompatibilities, Blood Group,Incompatibility, ABO,Incompatibility, Blood Group,Incompatibility, Blood Type,Incompatibility, Rh,Rh Compatibilities,Rh Incompatibilities
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D001803 Blood Transfusion The introduction of whole blood or blood component directly into the blood stream. (Dorland, 27th ed) Blood Transfusions,Transfusion, Blood,Transfusions, Blood
D001831 Body Temperature The measure of the level of heat of a human or animal. Organ Temperature,Body Temperatures,Organ Temperatures,Temperature, Body,Temperature, Organ,Temperatures, Body,Temperatures, Organ
D003298 Coombs Test A test to detect non-agglutinating ANTIBODIES against ERYTHROCYTES by use of anti-antibodies (the Coombs' reagent.) The direct test is applied to freshly drawn blood to detect antibody bound to circulating red cells. The indirect test is applied to serum to detect the presence of antibodies that can bind to red blood cells. Anti-Human Globulin Consumption Test,Antiglobulin Consumption Test,Antiglobulin Test,Coombs' Test,Antihuman Globulin Consumption Test,Direct Antiglobulin Test,Direct Coombs Test,Indirect Antiglobulin Test,Indirect Coombs Test,Anti Human Globulin Consumption Test,Antiglobulin Consumption Tests,Antiglobulin Test, Direct,Antiglobulin Test, Indirect,Antiglobulin Tests,Antiglobulin Tests, Direct,Antiglobulin Tests, Indirect,Consumption Test, Antiglobulin,Consumption Tests, Antiglobulin,Coomb Test,Coomb's Test,Coombs Test, Direct,Coombs Test, Indirect,Direct Antiglobulin Tests,Indirect Antiglobulin Tests,Test, Antiglobulin,Test, Antiglobulin Consumption,Test, Coombs,Test, Coombs',Test, Direct Antiglobulin,Test, Direct Coombs,Test, Indirect Antiglobulin,Test, Indirect Coombs,Tests, Antiglobulin,Tests, Antiglobulin Consumption,Tests, Direct Antiglobulin,Tests, Indirect Antiglobulin
D005260 Female Females
D005334 Fever An abnormal elevation of body temperature, usually as a result of a pathologic process. Pyrexia,Fevers,Pyrexias

Related Publications

A Wegmann, and H Hübner, and H Erb
December 1970, Deutsche medizinische Wochenschrift (1946),
A Wegmann, and H Hübner, and H Erb
September 1974, Praxis der Pneumologie,
A Wegmann, and H Hübner, and H Erb
September 1988, Clinical allergy,
A Wegmann, and H Hübner, and H Erb
May 1977, Deutsche medizinische Wochenschrift (1946),
A Wegmann, and H Hübner, and H Erb
January 1977, Polski przeglad radiologii i medycyny nuklearnej,
A Wegmann, and H Hübner, and H Erb
February 1975, Medizinische Klinik,
A Wegmann, and H Hübner, and H Erb
August 2008, American journal of hematology,
A Wegmann, and H Hübner, and H Erb
April 1979, European journal of obstetrics, gynecology, and reproductive biology,
A Wegmann, and H Hübner, and H Erb
July 1980, Deutsche medizinische Wochenschrift (1946),
Copied contents to your clipboard!