Relationship between dialyser type and signs and symptoms. 1993

N W Levin, and G Zasuwa
Division of Nephrology, Henry Ford Hospital, Detroit, MI 48202.

A crossover study to compare the effects of seven different dialysers on intradialytic symptoms in 37 patients during dialysis with acetate-containing dialysate was performed at five centres in four countries. The same manufacturing lot of each dialyser and of blood line sets were used by all centres. The same clinical data (duration of dialysis, blood pressure, weights, temperature, drugs, symptoms, and treatments) and technical data (blood flow, dialyser clearance, and ultrafiltration rate) were collected. Kt/V for urea was used to determine dialysis prescribed. Intradialytic symptoms and signs were measured hourly or when observed by staff using the haemodialysis treatment form (see Introduction). After each week of treatment with a particular dialyser, patients completed a questionnaire relating to the presence and severity of symptoms. (Only presence or absence of symptoms are presented.) Wide differences in dialysis duration and blood flow between centres were noted. These may have contributed to the differences between centres in relationship to staff reported responses to different dialyser: Dialysers with the lowest incidence of both signs and symptoms and of chest pain, back pain, and itching (arbitrarily designated bioincompatibility symptoms) were the Duo-Flux and Filtral, with the G120 M, the CD 4000, and the T 150 having the highest incidence. By patient questionnaire the most biocompatible dialysers were the T 150, F 60, and the Filtral, with the most symptom producing being the G120 M and the G10-3N. Perceptions of symptoms between patients and staff differed substantially overall and between centres. Hypersensitivity reactions were noted in two patients, both occurring with cuprammonium cellulose hollow-fibre dialysis, despite adherence to manufacturers' instructions concerning saline priming and removal. Both patients showed antibody titres greater than 1:160 against ethylene oxide-HSA. Ethylene oxide was not detected (limit of detection 1 part per million) in dialysers, blood line sets, or fistula needles. The study suggests that dialysis symptom reporting is complicated by individual perceptions, staff reactions, and the efficiency of recording. In this study ethnic and cultural differences must be added to the haemodynamic differences and other prescription-related elements in influencing symptoms. Despite these problems a hierarchy of dialyser-related symptoms and signs could be discerned which largely paralleled laboratory findings of biocompatibility. Future comparative studies relating symptomatology to membrane and dialyser structure should consider the variables identified as influencing symptoms and their reporting.

UI MeSH Term Description Entries
D007676 Kidney Failure, Chronic The end-stage of CHRONIC RENAL INSUFFICIENCY. It is characterized by the severe irreversible kidney damage (as measured by the level of PROTEINURIA) and the reduction in GLOMERULAR FILTRATION RATE to less than 15 ml per min (Kidney Foundation: Kidney Disease Outcome Quality Initiative, 2002). These patients generally require HEMODIALYSIS or KIDNEY TRANSPLANTATION. ESRD,End-Stage Renal Disease,Renal Disease, End-Stage,Renal Failure, Chronic,Renal Failure, End-Stage,Chronic Kidney Failure,End-Stage Kidney Disease,Chronic Renal Failure,Disease, End-Stage Kidney,Disease, End-Stage Renal,End Stage Kidney Disease,End Stage Renal Disease,End-Stage Renal Failure,Kidney Disease, End-Stage,Renal Disease, End Stage,Renal Failure, End Stage
D010361 Patients Individuals participating in the health care system for the purpose of receiving therapeutic, diagnostic, or preventive procedures. Clients,Client,Patient
D011795 Surveys and Questionnaires Collections of data obtained from voluntary subjects. The information usually takes the form of answers to questions, or suggestions. Community Survey,Nonrespondent,Questionnaire,Questionnaires,Respondent,Survey,Survey Method,Survey Methods,Surveys,Baseline Survey,Community Surveys,Methodology, Survey,Nonrespondents,Questionnaire Design,Randomized Response Technique,Repeated Rounds of Survey,Respondents,Survey Methodology,Baseline Surveys,Design, Questionnaire,Designs, Questionnaire,Methods, Survey,Questionnaire Designs,Questionnaires and Surveys,Randomized Response Techniques,Response Technique, Randomized,Response Techniques, Randomized,Survey, Baseline,Survey, Community,Surveys, Baseline,Surveys, Community,Techniques, Randomized Response
D002482 Cellulose A polysaccharide with glucose units linked as in CELLOBIOSE. It is the chief constituent of plant fibers, cotton being the purest natural form of the substance. As a raw material, it forms the basis for many derivatives used in chromatography, ion exchange materials, explosives manufacturing, and pharmaceutical preparations. Alphacel,Avicel,Heweten,Polyanhydroglucuronic Acid,Rayophane,Sulfite Cellulose,alpha-Cellulose,Acid, Polyanhydroglucuronic,alpha Cellulose
D004342 Drug Hypersensitivity Immunologically mediated adverse reactions to medicinal substances used legally or illegally. Allergy, Drug,Hypersensitivity, Drug,Drug Allergy,Allergies, Drug,Drug Allergies,Drug Hypersensitivities,Hypersensitivities, Drug
D004864 Equipment and Supplies Expendable and nonexpendable equipment, supplies, apparatus, and instruments that are used in diagnostic, surgical, therapeutic, scientific, and experimental procedures. Apparatus and Instruments,Devices,Medical Devices,Device, Medical,Devices, Medical,Equipment,Inventories,Medical Device,Supplies,Device,Instruments and Apparatus,Inventory,Supplies and Equipment
D006435 Renal Dialysis Therapy for the insufficient cleansing of the BLOOD by the kidneys based on dialysis and including hemodialysis, PERITONEAL DIALYSIS, and HEMODIAFILTRATION. Dialysis, Extracorporeal,Dialysis, Renal,Extracorporeal Dialysis,Hemodialysis,Dialyses, Extracorporeal,Dialyses, Renal,Extracorporeal Dialyses,Hemodialyses,Renal Dialyses
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001672 Biocompatible Materials Synthetic or natural materials, other than DRUGS, that are used to replace or repair any body TISSUES or bodily function. Biomaterials,Bioartificial Materials,Hemocompatible Materials,Bioartificial Material,Biocompatible Material,Biomaterial,Hemocompatible Material,Material, Bioartificial,Material, Biocompatible,Material, Hemocompatible

Related Publications

N W Levin, and G Zasuwa
September 2013, Optometry and vision science : official publication of the American Academy of Optometry,
N W Levin, and G Zasuwa
April 2011, Eye (London, England),
N W Levin, and G Zasuwa
August 1986, Community dentistry and oral epidemiology,
N W Levin, and G Zasuwa
July 2006, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases,
N W Levin, and G Zasuwa
January 1988, ASDC journal of dentistry for children,
N W Levin, and G Zasuwa
August 2018, European journal of cardiovascular nursing,
N W Levin, and G Zasuwa
December 2018, Journal of current ophthalmology,
N W Levin, and G Zasuwa
March 2007, Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology,
Copied contents to your clipboard!