Patch-clamp recording from Müller (glial) cell endfeet in the intact isolated retina and acutely isolated Müller cells of mouse and guinea-pig. 1993

W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
University of Heidelberg, Department of Neurobiology, Germany.

Müller cells span through the entire retina and terminate with the formation of endfeet at the vitreous body. These endfeet are thought to be specialized for maintaining the K+ homeostasis in the retina based on the assumption that voltage signals can passively spread from the cell body to the endfeet. We employed the patch-clamp technique to study the physiological properties of these endfeet in a retinal wholemount preparation from guinea-pig or mouse. After assessing one endfoot with the patch pipette and establishing the whole cell recording configuration, a membrane area which approximately matched the size of one endfoot and proximal process could be voltage-clamped. This morphological correlation could be established by filling the cytoplasm with the fluorescent dye Lucifer Yellow via the patch-pipette. The morphological, immunocytochemical and ultrastructural inspection of the recorded cells revealed that mouse Müller cell endfeet were connected by only a thin stalk to the proximal process. In contrast, guinea-pig endfeet were connected by thick stalks. The endfoot current in the mouse was dominated by a voltage and time-independent K+ conductance. In contrast, in some of the recordings from guinea-pig, delayed and inwardly rectifying K+ currents were observed. These voltage-gated currents were more frequently observed or were facilitated when the membrane area under voltage clamp was increased, blocking the passive K+ currents by Ba2+ in both, mouse and guinea-pig. We thus assume that the voltage-gated currents were not in the endfeet membrane, but rather in the proximal process and could thus be better activated in the guinea-pig with its thicker stalk or after increasing the membrane area under voltage clamp control. Similar results were obtained in freshly isolated Müller cells; in contrast to the cells from the wholemount the voltage-gated currents were more frequently observed. These studies demonstrate that the Müller cell endfoot of the mouse with its vascularized retina is an electrically isolated unit and that voltage signals do not spread to the proximal process. Such a property would, however, be required for the redistribution of K+ via spatial buffer currents. In contrast, guinea-pig Müller glial cells with their stout morphological connection between endfoot and proximal process are better suited to fulfil this task.

UI MeSH Term Description Entries
D007150 Immunohistochemistry Histochemical localization of immunoreactive substances using labeled antibodies as reagents. Immunocytochemistry,Immunogold Techniques,Immunogold-Silver Techniques,Immunohistocytochemistry,Immunolabeling Techniques,Immunogold Technics,Immunogold-Silver Technics,Immunolabeling Technics,Immunogold Silver Technics,Immunogold Silver Techniques,Immunogold Technic,Immunogold Technique,Immunogold-Silver Technic,Immunogold-Silver Technique,Immunolabeling Technic,Immunolabeling Technique,Technic, Immunogold,Technic, Immunogold-Silver,Technic, Immunolabeling,Technics, Immunogold,Technics, Immunogold-Silver,Technics, Immunolabeling,Technique, Immunogold,Technique, Immunogold-Silver,Technique, Immunolabeling,Techniques, Immunogold,Techniques, Immunogold-Silver,Techniques, Immunolabeling
D007546 Isoquinolines A group of compounds with the heterocyclic ring structure of benzo(c)pyridine. The ring structure is characteristic of the group of opium alkaloids such as papaverine. (From Stedman, 25th ed)
D008564 Membrane Potentials The voltage differences across a membrane. For cellular membranes they are computed by subtracting the voltage measured outside the membrane from the voltage measured inside the membrane. They result from differences of inside versus outside concentration of potassium, sodium, chloride, and other ions across cells' or ORGANELLES membranes. For excitable cells, the resting membrane potentials range between -30 and -100 millivolts. Physical, chemical, or electrical stimuli can make a membrane potential more negative (hyperpolarization), or less negative (depolarization). Resting Potentials,Transmembrane Potentials,Delta Psi,Resting Membrane Potential,Transmembrane Electrical Potential Difference,Transmembrane Potential Difference,Difference, Transmembrane Potential,Differences, Transmembrane Potential,Membrane Potential,Membrane Potential, Resting,Membrane Potentials, Resting,Potential Difference, Transmembrane,Potential Differences, Transmembrane,Potential, Membrane,Potential, Resting,Potential, Transmembrane,Potentials, Membrane,Potentials, Resting,Potentials, Transmembrane,Resting Membrane Potentials,Resting Potential,Transmembrane Potential,Transmembrane Potential Differences
D008810 Mice, Inbred C57BL One of the first INBRED MOUSE STRAINS to be sequenced. This strain is commonly used as genetic background for transgenic mouse models. Refractory to many tumors, this strain is also preferred model for studying role of genetic variations in development of diseases. Mice, C57BL,Mouse, C57BL,Mouse, Inbred C57BL,C57BL Mice,C57BL Mice, Inbred,C57BL Mouse,C57BL Mouse, Inbred,Inbred C57BL Mice,Inbred C57BL Mouse
D008854 Microscopy, Electron Microscopy using an electron beam, instead of light, to visualize the sample, thereby allowing much greater magnification. The interactions of ELECTRONS with specimens are used to provide information about the fine structure of that specimen. In TRANSMISSION ELECTRON MICROSCOPY the reactions of the electrons that are transmitted through the specimen are imaged. In SCANNING ELECTRON MICROSCOPY an electron beam falls at a non-normal angle on the specimen and the image is derived from the reactions occurring above the plane of the specimen. Electron Microscopy
D009457 Neuroglia The non-neuronal cells of the nervous system. They not only provide physical support, but also respond to injury, regulate the ionic and chemical composition of the extracellular milieu, participate in the BLOOD-BRAIN BARRIER and BLOOD-RETINAL BARRIER, form the myelin insulation of nervous pathways, guide neuronal migration during development, and exchange metabolites with neurons. Neuroglia have high-affinity transmitter uptake systems, voltage-dependent and transmitter-gated ion channels, and can release transmitters, but their role in signaling (as in many other functions) is unclear. Bergmann Glia,Bergmann Glia Cells,Bergmann Glial Cells,Glia,Glia Cells,Satellite Glia,Satellite Glia Cells,Satellite Glial Cells,Glial Cells,Neuroglial Cells,Bergmann Glia Cell,Bergmann Glial Cell,Cell, Bergmann Glia,Cell, Bergmann Glial,Cell, Glia,Cell, Glial,Cell, Neuroglial,Cell, Satellite Glia,Cell, Satellite Glial,Glia Cell,Glia Cell, Bergmann,Glia Cell, Satellite,Glia, Bergmann,Glia, Satellite,Glial Cell,Glial Cell, Bergmann,Glial Cell, Satellite,Glias,Neuroglial Cell,Neuroglias,Satellite Glia Cell,Satellite Glial Cell,Satellite Glias
D012160 Retina The ten-layered nervous tissue membrane of the eye. It is continuous with the OPTIC NERVE and receives images of external objects and transmits visual impulses to the brain. Its outer surface is in contact with the CHOROID and the inner surface with the VITREOUS BODY. The outer-most layer is pigmented, whereas the inner nine layers are transparent. Ora Serrata
D002469 Cell Separation Techniques for separating distinct populations of cells. Cell Isolation,Cell Segregation,Isolation, Cell,Cell Isolations,Cell Segregations,Cell Separations,Isolations, Cell,Segregation, Cell,Segregations, Cell,Separation, Cell,Separations, Cell
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D005456 Fluorescent Dyes Chemicals that emit light after excitation by light. The wave length of the emitted light is usually longer than that of the incident light. Fluorochromes are substances that cause fluorescence in other substances, i.e., dyes used to mark or label other compounds with fluorescent tags. Flourescent Agent,Fluorescent Dye,Fluorescent Probe,Fluorescent Probes,Fluorochrome,Fluorochromes,Fluorogenic Substrates,Fluorescence Agents,Fluorescent Agents,Fluorogenic Substrate,Agents, Fluorescence,Agents, Fluorescent,Dyes, Fluorescent,Probes, Fluorescent,Substrates, Fluorogenic

Related Publications

W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
October 2002, Journal of neuroscience methods,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
November 1994, Pflugers Archiv : European journal of physiology,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
September 2022, STAR protocols,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
September 1995, Glia,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
December 2011, Biophysical journal,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
December 2014, Journal of biological rhythms,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
June 1992, The American journal of physiology,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
February 1982, The Anatomical record,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
January 1998, Journal of neuroscience methods,
W Reichelt, and T Müller, and A Pastor, and T Pannicke, and P M Orkand, and H Kettenmann, and J Schnitzer
January 2016, Methods in molecular biology (Clifton, N.J.),
Copied contents to your clipboard!