Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion. 1993

S A Klem, and J M Farrington, and R D Leff
Department of Pediatrics, University of Kansas Medical Center, Kansas City.

OBJECTIVE To determine whether variations in the flow rate of epinephrine solutions administered via commonly available infusion pumps lead to significant variations in blood pressure (BP) in vivo. METHODS Prospective, randomized, crossover study with factorial design, using infusion pumps with four different operating mechanisms (pulsatile diaphragm, linear piston/syringe, cyclic piston-valve, and linear peristaltic) and three drug delivery rates (1, 5, and 10 mL/hr). METHODS Two healthy, mixed-breed dogs (12 to 16 kg). METHODS Dogs were made hypotensive with methohexital bolus and continuous infusion. BP was restored to normal with constant-dose epinephrine infusion via two pumps at each rate. METHODS Femoral mean arterial pressure (MAP) was recorded every 10 secs. Pump-flow continuity was quantitated in vitro using a digital gravimetric technique. Variations in MAP and flow continuity were expressed by the coefficient of variation; analysis of variance was used for comparisons. RESULTS The mean coefficients of variations for MAP varied from 3.8 +/- 3.1% (linear piston/syringe) to 6.1 +/- 6.6% (linear peristaltic), and from 3.4 +/- 2.2% (10 mL/hr) to 7.9 +/- 6.6% (1 mL/hr). The coefficients of variation for in vitro flow continuity ranged from 9 +/- 8% (linear piston-syringe) to 250 +/- 162% (pulsatile diaphragm), and from 35 +/- 44% (10 mL/hr) to 138 +/- 196% (1 mL/hr). Both the type of pump and infusion rate significantly (p < .001) influenced variation in drug delivery rate. The 1 mL/hr infusion rate significantly (p < .01) influenced MAP variation. Cyclic fluctuations in MAP of < or = 30 mm Hg were observed using the pulsatile diaphragm pump at 1 mL/hr. CONCLUSIONS Factors inherent in the operating mechanisms of infusion pumps may result in clinically important hemodynamic fluctuations when administering a concentrated short-acting vasoactive medication at slow infusion rates.

UI MeSH Term Description Entries
D007260 Infusion Pumps Fluid propulsion systems driven mechanically, electrically, or osmotically that are used to inject (or infuse) over time agents into a patient or experimental animal; used routinely in hospitals to maintain a patent intravenous line, to administer antineoplastic agents and other drugs in thromboembolism, heart disease, diabetes mellitus (INSULIN INFUSION SYSTEMS is also available), and other disorders. Drug Infusion Systems,Infusion Pump,Infusion Pumps, External,Infusors,Intravenous Drug Delivery System,Intravenous Drug Delivery Systems,Perfusion Pumps,Pumps, Infusion,Drug Infusion System,External Infusion Pump,External Infusion Pumps,Infusion Pump, External,Infusion System, Drug,Infusion Systems, Drug,Infusor,Perfusion Pump,Pump, External Infusion,Pump, Infusion,Pump, Perfusion,Pumps, External Infusion,Pumps, Perfusion,System, Drug Infusion,Systems, Drug Infusion
D007262 Infusions, Intravenous The long-term (minutes to hours) administration of a fluid into the vein through venipuncture, either by letting the fluid flow by gravity or by pumping it. Drip Infusions,Intravenous Drip,Intravenous Infusions,Drip Infusion,Drip, Intravenous,Infusion, Drip,Infusion, Intravenous,Infusions, Drip,Intravenous Infusion
D011673 Pulsatile Flow Rhythmic, intermittent propagation of a fluid through a BLOOD VESSEL or piping system, in contrast to constant, smooth propagation, which produces laminar flow. Flow, Pulsating,Perfusion, Pulsatile,Flow, Pulsatile,Flows, Pulsatile,Flows, Pulsating,Perfusions, Pulsatile,Pulsatile Flows,Pulsatile Perfusion,Pulsatile Perfusions,Pulsating Flow,Pulsating Flows
D011897 Random Allocation A process involving chance used in therapeutic trials or other research endeavor for allocating experimental subjects, human or animal, between treatment and control groups, or among treatment groups. It may also apply to experiments on inanimate objects. Randomization,Allocation, Random
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D004195 Disease Models, Animal Naturally-occurring or experimentally-induced animal diseases with pathological processes analogous to human diseases. Animal Disease Model,Animal Disease Models,Disease Model, Animal
D004285 Dogs The domestic dog, Canis familiaris, comprising about 400 breeds, of the carnivore family CANIDAE. They are worldwide in distribution and live in association with people. (Walker's Mammals of the World, 5th ed, p1065) Canis familiaris,Dog
D004837 Epinephrine The active sympathomimetic hormone from the ADRENAL MEDULLA. It stimulates both the alpha- and beta- adrenergic systems, causes systemic VASOCONSTRICTION and gastrointestinal relaxation, stimulates the HEART, and dilates BRONCHI and cerebral vessels. It is used in ASTHMA and CARDIAC FAILURE and to delay absorption of local ANESTHETICS. Adrenaline,4-(1-Hydroxy-2-(methylamino)ethyl)-1,2-benzenediol,Adrenaline Acid Tartrate,Adrenaline Bitartrate,Adrenaline Hydrochloride,Epifrin,Epinephrine Acetate,Epinephrine Bitartrate,Epinephrine Hydrochloride,Epinephrine Hydrogen Tartrate,Epitrate,Lyophrin,Medihaler-Epi,Acetate, Epinephrine
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment

Related Publications

S A Klem, and J M Farrington, and R D Leff
August 1994, Critical care medicine,
S A Klem, and J M Farrington, and R D Leff
September 1970, Archives internationales de pharmacodynamie et de therapie,
S A Klem, and J M Farrington, and R D Leff
June 2002, Journal of clinical anesthesia,
S A Klem, and J M Farrington, and R D Leff
January 1962, Journal of applied physiology,
S A Klem, and J M Farrington, and R D Leff
September 1990, Clinical pharmacology and therapeutics,
S A Klem, and J M Farrington, and R D Leff
January 2024, Journal of infusion nursing : the official publication of the Infusion Nurses Society,
S A Klem, and J M Farrington, and R D Leff
April 1993, American journal of hospital pharmacy,
S A Klem, and J M Farrington, and R D Leff
February 1969, Archives internationales de physiologie et de biochimie,
S A Klem, and J M Farrington, and R D Leff
June 2011, Japan journal of nursing science : JJNS,
S A Klem, and J M Farrington, and R D Leff
April 2015, Indoor air,
Copied contents to your clipboard!