Review of seven cardiac electrophysiology stimulators. 1993

N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne, UK.

Seven cardiac electrophysiology stimulators from four manufacturers (Biotronik, Bloom, Digitimer and Medtronic) in common current use are reviewed. The stimulators differ in the features provided and the design adopted to achieve these features. The number of output channels ranges from one to four, the number of extra-stimuli available ranges from two to six, and these can be delivered as a variety of sequences. Some of the stimulators (Digitimer and Bloom) are modular while others (Biotronik and Medtronic 532 series) are of an integrated design comprising a single physical unit. The design of the Medtronic EP-2 has both integrated and modular characteristics. The features of the stimulators associated with input, output, control and the user interface are specifically reviewed. The features are also compared against the published recommendations of the American Heart Association. In addition, a summary of stimulator user comments from a number of electrophysiology centres is presented. All of the stimulators fulfil, or are close to fulfilling, basic electrophysiological requirements, but some provide more complex facilities such as would be required by specialist centres.

UI MeSH Term Description Entries
D004558 Electric Stimulation Use of electric potential or currents to elicit biological responses. Stimulation, Electric,Electrical Stimulation,Electric Stimulations,Electrical Stimulations,Stimulation, Electrical,Stimulations, Electric,Stimulations, Electrical
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
May 1987, Revue de l'infirmiere,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
October 1974, Revue de l'infirmiere,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
July 2018, Circulation. Arrhythmia and electrophysiology,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
February 2019, Circulation. Arrhythmia and electrophysiology,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
June 2020, Circulation. Arrhythmia and electrophysiology,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
December 1980, al-Maghrib al-tibbi. Maroc medical,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
January 2019, Cardiology in review,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
August 2009, Journal of the American College of Cardiology,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
February 2013, Journal of the American College of Cardiology,
N B McLaughlin, and C J Griffiths, and R W Campbell, and A Murray
May 2008, Journal of the American College of Cardiology,
Copied contents to your clipboard!