[Late valvular dysfunction after mechanical mitral valve replacement]. 1993

M Cottogni, and H Antretter, and W Furtwängler
Abteilung für Herzchirurgie, Universität Innsbruck.

14 years after a Björk-Shiley prosthesis had been implanted because of combined mitral failure, a 68-year-old woman complained of progressive decrease of physical powers combined with apnoea, retrosternal feeling of pressure and tachycardiac atrial fibrillation. Five weeks later, onset of cardiac decompensation with dyspnoea at rest and signs of congested pulmonary circulation were noted. Echocardiography revealed stenosis of the mitral valve prosthesis. The patient was operated on two days later. It became evident that the patency of the prosthesis was greatly obstructed by connective tissue which had proliferated at the ventricular side. The original valve prosthesis was replaced by a St. Jude bi-leaflet valve. The likelihood of prosthesis dysfunction must always be considered if there is a deterioration in the patient's condition after a long uncomplicated postoperative course following cardiac valve replacement.

UI MeSH Term Description Entries
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D008946 Mitral Valve Stenosis Narrowing of the passage through the MITRAL VALVE due to FIBROSIS, and CALCINOSIS in the leaflets and chordal areas. This elevates the left atrial pressure which, in turn, raises pulmonary venous and capillary pressure leading to bouts of DYSPNEA and TACHYCARDIA during physical exertion. RHEUMATIC FEVER is its primary cause. Mitral Stenosis,Mitral Stenoses,Mitral Valve Stenoses,Stenoses, Mitral,Stenoses, Mitral Valve,Stenosis, Mitral,Stenosis, Mitral Valve,Valve Stenoses, Mitral,Valve Stenosis, Mitral
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

M Cottogni, and H Antretter, and W Furtwängler
May 2003, The Journal of heart valve disease,
M Cottogni, and H Antretter, and W Furtwängler
April 2001, Nihon Geka Gakkai zasshi,
M Cottogni, and H Antretter, and W Furtwängler
November 2019, Journal of cardiac surgery,
M Cottogni, and H Antretter, and W Furtwängler
July 1966, British medical journal,
M Cottogni, and H Antretter, and W Furtwängler
November 1985, La Tunisie medicale,
M Cottogni, and H Antretter, and W Furtwängler
April 2001, The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi,
M Cottogni, and H Antretter, and W Furtwängler
January 2022, Kardiologia polska,
M Cottogni, and H Antretter, and W Furtwängler
April 2002, The Annals of thoracic surgery,
M Cottogni, and H Antretter, and W Furtwängler
December 2011, The Thoracic and cardiovascular surgeon,
Copied contents to your clipboard!