An approach in the assessment of pacing hemodynamics: a comparison of VVI and DDD. 1995

G E Payne, and H Williams, and J D Skehan
Glenfield Hospital, Leicester, United Kingdom.

Previous methods for assessment of pacemaker hemodynamics have been limited to a rigid hospital environment. An alternative is the ambulatory ventricular function monitor (C-VEST) that, with a single injection of technetium-99m, permits the continuous measurement of relative ejection fraction (EF) and cardiac output (CO) during the activities of daily living. A study of reproducibility and a comparison of dual chamber (DDD) and fixed rate ventricular (VVI) pacing are presented. Reproducibility was assessed in six patients (4 males; mean age 58, range 27-78 years) with a mean EF of 48.5% (range 34%-62%) and DDD pacemakers, implanted for conduction abnormalities. In addition, 11 patients (7 males; mean age 55.5, range 34-75 years) with a mean EF of 48.5% (range 34%-65%), chronic complete heart block, and DDD pacemakers were used for the comparative study. After an initial multigated scan, the monitor was positioned over the left ventricle and kept in place with the plastic C-VEST. The patients undergoing the reproducibility study performed three shuttle walking tests with 20 minutes of rest in between. The patients in the comparative study were randomized to either VVI or DDD mode and performed one shuttle walking test in each pacing mode. The results confirmed that the C-VEST produces reproducible results with no significant difference in peak CO between the three shuttle walks. In addition, it confirmed previous hemodynamic studies showing that DDD pacing was superior to VVI pacing both at rest (P < 0.004) and at exercise (P < 0.002). These findings show the C-VEST to be an extremely useful tool for the hemodynamic assessment of pacemaker patients.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004311 Double-Blind Method A method of studying a drug or procedure in which both the subjects and investigators are kept unaware of who is actually getting which specific treatment. Double-Masked Study,Double-Blind Study,Double-Masked Method,Double Blind Method,Double Blind Study,Double Masked Method,Double Masked Study,Double-Blind Methods,Double-Blind Studies,Double-Masked Methods,Double-Masked Studies,Method, Double-Blind,Method, Double-Masked,Methods, Double-Blind,Methods, Double-Masked,Studies, Double-Blind,Studies, Double-Masked,Study, Double-Blind,Study, Double-Masked
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic

Related Publications

G E Payne, and H Williams, and J D Skehan
February 1988, The American journal of cardiology,
G E Payne, and H Williams, and J D Skehan
May 1989, Pacing and clinical electrophysiology : PACE,
G E Payne, and H Williams, and J D Skehan
May 2006, Journal of cardiovascular electrophysiology,
G E Payne, and H Williams, and J D Skehan
May 1997, Heart (British Cardiac Society),
G E Payne, and H Williams, and J D Skehan
July 1995, Echocardiography (Mount Kisco, N.Y.),
G E Payne, and H Williams, and J D Skehan
July 1992, European heart journal,
G E Payne, and H Williams, and J D Skehan
January 1988, Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology,
G E Payne, and H Williams, and J D Skehan
March 1996, Pacing and clinical electrophysiology : PACE,
G E Payne, and H Williams, and J D Skehan
January 2004, Cardiology,
G E Payne, and H Williams, and J D Skehan
February 1990, Nihon rinsho. Japanese journal of clinical medicine,
Copied contents to your clipboard!