Compton scatter imaging of transverse sections: corrections for multiple scatter and attenuation. 1977

J J Battista, and L W Santon, and M J Bronskill

The electron density (e cm-3) of a tissue sample can be determined by measuring the fluence of photons which it Compton scatters from a narrow incident beam of X- or gamma-radiation. This technique has been applied successfully to diagnostic denistometry (bone, lung), and less successfully to whole body tomography. In this work, the physics of Compton scatter tomography is examined with emphasis on transverse section scanning. The two major limitations of the scatter technique, attenuation of the single scatter photon fluence (of interest), and contamination of this fluence by multiply-scattered photons, are studied and corrective procedures are proposed. The methods described are applied to a simple test phantom; it is concluded that transverse images with an electron density precision of approximately 5% are possible.

UI MeSH Term Description Entries
D008961 Models, Structural A representation, generally small in scale, to show the structure, construction, or appearance of something. (From Random House Unabridged Dictionary, 2d ed) Model, Structural,Structural Model,Structural Models
D008962 Models, Theoretical Theoretical representations that simulate the behavior or activity of systems, processes, or phenomena. They include the use of mathematical equations, computers, and other electronic equipment. Experimental Model,Experimental Models,Mathematical Model,Model, Experimental,Models (Theoretical),Models, Experimental,Models, Theoretic,Theoretical Study,Mathematical Models,Model (Theoretical),Model, Mathematical,Model, Theoretical,Models, Mathematical,Studies, Theoretical,Study, Theoretical,Theoretical Model,Theoretical Models,Theoretical Studies
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D005720 Gamma Rays Penetrating, high-energy electromagnetic radiation emitted from atomic nuclei during NUCLEAR DECAY. The range of wavelengths of emitted radiation is between 0.1 - 100 pm which overlaps the shorter, more energetic hard X-RAYS wavelengths. The distinction between gamma rays and X-rays is based on their radiation source. Gamma Wave,Gamma Radiation,Nuclear X-Rays,Radiation, Gamma,X-Rays, Nuclear,Gamma Radiations,Gamma Ray,Gamma Waves,Nuclear X Rays,Nuclear X-Ray,Ray, Gamma,Wave, Gamma,Waves, Gamma,X Rays, Nuclear,X-Ray, Nuclear
D000388 Air The mixture of gases present in the earth's atmosphere consisting of oxygen, nitrogen, carbon dioxide, and small amounts of other gases.
D012542 Scattering, Radiation The diversion of RADIATION (thermal, electromagnetic, or nuclear) from its original path as a result of interactions or collisions with atoms, molecules, or larger particles in the atmosphere or other media. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Radiation Scattering,Radiation Scatterings,Scatterings, Radiation
D014056 Tomography, X-Ray Tomography using x-ray transmission. Tomography, Transmission,X-Ray Tomography,Zonography,Radiographic Tomography,Tomography, Radiographic,Tomography, X Ray,Tomography, Xray,Transmission Tomography,X Ray Tomography,Xray Tomography
D014965 X-Rays Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source. Grenz Ray,Grenz Rays,Roentgen Ray,Roentgen Rays,X Ray,X-Ray,Xray,Radiation, X,X-Radiation,Xrays,Ray, Grenz,Ray, Roentgen,Ray, X,Rays, Grenz,Rays, Roentgen,Rays, X,X Radiation,X Rays,X-Radiations

Related Publications

J J Battista, and L W Santon, and M J Bronskill
January 1981, Physics in medicine and biology,
J J Battista, and L W Santon, and M J Bronskill
September 2009, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society,
J J Battista, and L W Santon, and M J Bronskill
February 1996, Neurological research,
J J Battista, and L W Santon, and M J Bronskill
April 2003, Cancer biotherapy & radiopharmaceuticals,
J J Battista, and L W Santon, and M J Bronskill
June 2010, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
J J Battista, and L W Santon, and M J Bronskill
December 2012, Computer methods and programs in biomedicine,
J J Battista, and L W Santon, and M J Bronskill
November 1996, Physics in medicine and biology,
J J Battista, and L W Santon, and M J Bronskill
January 1978, Physics in medicine and biology,
J J Battista, and L W Santon, and M J Bronskill
July 2002, European journal of nuclear medicine and molecular imaging,
J J Battista, and L W Santon, and M J Bronskill
January 1988, Medical physics,
Copied contents to your clipboard!