A disposable, coated wire heparin sensor. 1994

J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
College of Pharmacy, University of Michigan, Ann Arbor 48109-1065, USA.

The development of an ion-selective electrode heparin sensor consisting of a specially formulated polymer membrane doped with tridodecylmethylammonium chloride as the heparin complexing agent was recently reported. Because of the simple nature of the membrane technology used, the authors envisioned that the sensor could be configured as a disposable single-use device for rapid clinical or bedside measurement of heparin in a small, discrete sample. To explore this possibility, an inexpensive, disposable heparin sensor was created by dip-coating a copper wire with the specially formulated heparin-sensing polymeric membrane. Coated wire heparin sensors with a broad range of membrane thicknesses, prepared by repeatedly dipping the wire in the membrane solution for various times, were examined. Data show that increasing the membrane thickness of the sensor to a certain degree (more than 10 microns) enhanced the sensor's potentiometric response to heparin, although the time required to achieve 90% of the steady-state potential change was also prolonged. In addition, increasing membrane thickness also magnified the stirring effect on the sensor's response. In undiluted plasma samples, the coated-wire sensor with an optimized membrane thickness yielded a significant (5 to 30 mV) and reproducible response to heparin in a clinically relevant concentration range (0.5 to 12 units/ml, respectively). The clinical utility of the coated wire heparin sensor was shown using the sensor during protamine titration of heparinized plasma to assess the titration end-point. Preliminary results showed that the titration end-points determined by the heparin sensor strongly correlated with those determined by the activated partial thromboplastin time clotting assay. The overall time requirement to complete the titration process using a set of prefabricated coated wire heparin sensors, however, was less than 3 minutes. Further titration studies using undiluted clinical whole blood samples are in progress.

UI MeSH Term Description Entries
D010314 Partial Thromboplastin Time The time required for the appearance of FIBRIN strands following the mixing of PLASMA with phospholipid platelet substitute (e.g., crude cephalins, soybean phosphatides). It is a test of the intrinsic pathway (factors VIII, IX, XI, and XII) and the common pathway (fibrinogen, prothrombin, factors V and X) of BLOOD COAGULATION. It is used as a screening test and to monitor HEPARIN therapy. Activated Partial Thromboplastin Time,Cephalin-Kaolin Coagulation Time,Kaolin-Cephalin Coagulation Time,Thromboplastin Time, Partial,Coagulation Time, Cephalin-Kaolin,Cephalin Kaolin Coagulation Time,Coagulation Time, Cephalin Kaolin,Coagulation Time, Kaolin-Cephalin,Kaolin Cephalin Coagulation Time
D011199 Potentiometry Solution titration in which the end point is read from the electrode-potential variations with the concentrations of potential determining ions. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed)
D001774 Blood Chemical Analysis An examination of chemicals in the blood. Analysis, Blood Chemical,Chemical Analysis, Blood,Analyses, Blood Chemical,Blood Chemical Analyses,Chemical Analyses, Blood
D003300 Copper A heavy metal trace element with the atomic symbol Cu, atomic number 29, and atomic weight 63.55. Copper-63,Copper 63
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006493 Heparin A highly acidic mucopolysaccharide formed of equal parts of sulfated D-glucosamine and D-glucuronic acid with sulfaminic bridges. The molecular weight ranges from six to twenty thousand. Heparin occurs in and is obtained from liver, lung, mast cells, etc., of vertebrates. Its function is unknown, but it is used to prevent blood clotting in vivo and vitro, in the form of many different salts. Heparinic Acid,alpha-Heparin,Heparin Sodium,Liquaemin,Sodium Heparin,Unfractionated Heparin,Heparin, Sodium,Heparin, Unfractionated,alpha Heparin
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000644 Quaternary Ammonium Compounds Derivatives of ammonium compounds, NH4+ Y-, in which all four of the hydrogens bonded to nitrogen have been replaced with hydrocarbyl groups. These are distinguished from IMINES which are RN Quaternary Ammonium Compound,Ammonium Compound, Quaternary,Ammonium Compounds, Quaternary,Compound, Quaternary Ammonium
D001709 Biotechnology Body of knowledge related to the use of organisms, cells or cell-derived constituents for the purpose of developing products which are technically, scientifically and clinically useful. Alteration of biologic function at the molecular level (i.e., GENETIC ENGINEERING) is a central focus; laboratory methods used include TRANSFECTION and CLONING technologies, sequence and structure analysis algorithms, computer databases, and gene and protein structure function analysis and prediction. Biotechnologies

Related Publications

J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
January 1988, Hormone and metabolic research. Supplement series,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
April 1986, Journal of biomedical engineering,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
January 2016, Optics express,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
March 2013, Analytica chimica acta,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
February 2015, Biosensors & bioelectronics,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
January 1993, Health devices,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
January 1997, American journal of physical medicine & rehabilitation,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
June 2014, Sensors (Basel, Switzerland),
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
January 1985, Surgery, gynecology & obstetrics,
J H Yun, and B Fu, and M E Meyerhoff, and V C Yang
January 1983, Advances in experimental medicine and biology,
Copied contents to your clipboard!