[Adaptive algorithm for automatic measurement of retinal vascular diameter]. 1995

K Münch, and W Vilser, and I Senff
Augenklinik des Klinikums, Friedrich-Schiller-Universität Jena.

A new adaptive computer-aided method for the measurement of blood vessel diameters has been developed. Within areas of interest in the image, the algorithm detects, line-wise, the edges of the vessels, which are then used for image-wise approximation and noise filtration. A high level of adaptivity with respect to numerous measuring parameters ensures its use in a wide range of applications. Thus, it has been shown to significantly improve clinically relevant reproducibility in the area of follow-up observations. The standard deviation for vessel diameter was (2.2 +/- 0.7)% in the case of arteries and (1.8 +/- 0.5)% in the case of veins. Testing the algorithm in images of poor quality revealed its high level of reliability and sensitivity.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D012161 Retinal Artery Central retinal artery and its branches. It arises from the ophthalmic artery, pierces the optic nerve and runs through its center, enters the eye through the porus opticus and branches to supply the retina. Central Retinal Artery,Arteries, Central Retinal,Arteries, Retinal,Artery, Central Retinal,Artery, Retinal,Central Retinal Arteries,Retinal Arteries,Retinal Arteries, Central,Retinal Artery, Central
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D012171 Retinal Vessels The blood vessels which supply and drain the RETINA. Pecten Oculi,Retinal Vasculature,Retinal Blood Vessels,Retinal Blood Vessel,Retinal Vasculatures,Retinal Vessel,Vasculature, Retinal,Vessel, Retinal,Vessel, Retinal Blood
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D019721 Ophthalmoscopes Devices for examining the interior of the eye, permitting the clear visualization of the structures of the eye at any depth. (UMDNS, 1999) Funduscopes,Funduscope,Ophthalmoscope

Related Publications

K Münch, and W Vilser, and I Senff
January 1991, Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft,
K Münch, and W Vilser, and I Senff
August 2016, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
K Münch, and W Vilser, and I Senff
July 2023, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
K Münch, and W Vilser, and I Senff
November 2010, Computer methods and programs in biomedicine,
K Münch, and W Vilser, and I Senff
January 1994, Biomedical sciences instrumentation,
K Münch, and W Vilser, and I Senff
January 2004, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference,
K Münch, and W Vilser, and I Senff
November 1976, Medical & biological engineering,
K Münch, and W Vilser, and I Senff
August 2017, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus,
K Münch, and W Vilser, and I Senff
April 1993, International journal of microcirculation, clinical and experimental,
Copied contents to your clipboard!