Clinical non-invasive measurement of effective pulmonary capillary blood flow. 1995

S M Winter
Section of Pulmonary and Critical Care Medicine, Norwalk Hospital, CT, USA.

Since traditional pulmonary function testing is centered on measurements of air flow and lung volume, a method to assess the pulmonary circulation might improve our ability to evaluate diseases that impact upon pulmonary hemodynamics. We have developed a PC based application that rapidly calculates pulmonary blood flow. Subjects rebreath a mixture of 10% argon and 3.5% freon for 20 seconds. Gas concentrations at the mouth are monitored by a clinical mass spectrometer and signals are acquired and processed with off-the-shelf hardware. To test the accuracy and reproducibility of this technique, patients with pulmonary artery catheters were assessed by standard thermodilution methods and the rebreathing test. Measurements using this non-invasive technology closely corelate with invasive thermodilution methods (r = 0.980) and show equivalent reproducibility (average standard error = 2.5%). This application of signal processing technology can extend the role of pulmonary function testing to include routine evaluation of the pulmonary circulation.

UI MeSH Term Description Entries
D008168 Lung Either of the pair of organs occupying the cavity of the thorax that effect the aeration of the blood. Lungs
D008176 Lung Volume Measurements Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle. Lung Capacities,Lung Volumes,Capacity, Lung,Lung Capacity,Lung Volume,Lung Volume Measurement,Measurement, Lung Volume,Volume, Lung
D008838 Microcomputers Small computers using LSI (large-scale integration) microprocessor chips as the CPU (central processing unit) and semiconductor memories for compact, inexpensive storage of program instructions and data. They are smaller and less expensive than minicomputers and are usually built into a dedicated system where they are optimized for a particular application. "Microprocessor" may refer to just the CPU or the entire microcomputer. Computers, Personal,Microprocessors,Computer, Personal,Microcomputer,Microprocessor,Personal Computer,Personal Computers
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D011652 Pulmonary Circulation The circulation of the BLOOD through the LUNGS. Pulmonary Blood Flow,Respiratory Circulation,Circulation, Pulmonary,Circulation, Respiratory,Blood Flow, Pulmonary,Flow, Pulmonary Blood,Pulmonary Blood Flows
D012123 Pulmonary Ventilation The total volume of gas inspired or expired per unit of time, usually measured in liters per minute. Respiratory Airflow,Ventilation Tests,Ventilation, Pulmonary,Expiratory Airflow,Airflow, Expiratory,Airflow, Respiratory,Test, Ventilation,Tests, Ventilation,Ventilation Test
D001834 Body Water Fluids composed mainly of water found within the body. Water, Body
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002407 Catheterization, Swan-Ganz Placement of a balloon-tipped catheter into the pulmonary artery through the antecubital, subclavian, and sometimes the femoral vein. It is used to measure pulmonary artery pressure and pulmonary artery wedge pressure which reflects left atrial pressure and left ventricular end-diastolic pressure. The catheter is threaded into the right atrium, the balloon is inflated and the catheter follows the blood flow through the tricuspid valve into the right ventricle and out into the pulmonary artery. Catheterization, Pulmonary Artery,Swan-Ganz Catheterization,Pulmonary Artery Catheterization,Artery Catheterization, Pulmonary,Artery Catheterizations, Pulmonary,Catheterization, Swan Ganz,Catheterizations, Pulmonary Artery,Pulmonary Artery Catheterizations,Swan Ganz Catheterization
D003199 Computer Systems Systems composed of a computer or computers, peripheral equipment, such as disks, printers, and terminals, and telecommunications capabilities. Computer Architecture,Computer System,Computer Systems Development,Computer Systems Evaluation,Computer Systems Organization,Real Time System,Real-Time Systems,Organization, Computer Systems,Architecture, Computer,Architectures, Computer,Computer Architectures,Computer Systems Evaluations,Development, Computer Systems,Evaluation, Computer Systems,Evaluations, Computer Systems,Real Time Systems,Real-Time System,System, Computer,System, Real Time,System, Real-Time,Systems, Computer,Systems, Real Time,Systems, Real-Time,Time System, Real,Time Systems, Real

Related Publications

S M Winter
March 1993, The Annals of thoracic surgery,
S M Winter
June 2000, Current opinion in anaesthesiology,
S M Winter
June 1997, British journal of anaesthesia,
S M Winter
June 1997, British journal of anaesthesia,
S M Winter
September 2006, La Tunisie medicale,
S M Winter
January 2022, Sensors (Basel, Switzerland),
S M Winter
March 1977, The Journal of clinical investigation,
S M Winter
November 1976, Acta paediatrica Scandinavica,
Copied contents to your clipboard!