Preliminary evaluation of a new continuous intra-arterial blood gas monitoring device. 1995

D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
Klinik für Anaesthesiologie and operative Intensivmedizin, Universitätsklinikum Rudolf Virchow, Freie Universität Berlin, Germany.

Continuous intra-arterial blood gas monitoring is a new technique, possibly offering therapeutic advantages through improved monitoring in patients prone to hypoxaemia, hypercapnia and/or respiratory acidosis. Therefore, we studied the clinical applicability, reliability, precision and side effect of long-term continuous intra-arterial blood gas monitoring in patients suffering from severe acute respiratory distress syndrome. In 10 patients continuous intra-arterial blood gas monitoring based on fluorescent optodes technique was performed. At 4 h intervals, arterial blood samples for in vitro blood gas analyses were drawn, stored in ice, and analysed within 3 min. Evaluation of data retrieved from the continuous intra-arterial blood gas monitoring and in vitro blood gas analysis was based on 596 data points using 10 catheters. Average length of insertion was 281 +/- 215 h, max. lengths of stay was 750 h. Arterial blood gas data obtained in vivo were compared to the mean of in vivo and in vitro arterial blood gases. Inter-catheter bias, expressed as percent difference between continuous intra-arterial blood gas and mean in vitro blood gas analysis was 0.19 +/- 0.23% for pH. 1.1 +/- 5.2% for PaCO2 and 1.6 +/- 5.7% for PaO2. No significant gas partial pressure dependent change in precision was demonstrable. There was no significant time dependent drift in sensor precision over the study period. No negative side-effects related to IABG monitoring were observed. We conclude that long-term use of this new device is possible in patients and represents a reliable alternative to conventional in vitro arterial blood gas analysis, when continuous monitoring of blood gases and/or acid-base balance is critical.

UI MeSH Term Description Entries
D007902 Length of Stay The period of confinement of a patient to a hospital or other health facility. Hospital Stay,Hospital Stays,Stay Length,Stay Lengths,Stay, Hospital,Stays, Hospital
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D010313 Partial Pressure The pressure that would be exerted by one component of a mixture of gases if it were present alone in a container. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Partial Pressures,Pressure, Partial,Pressures, Partial
D012128 Respiratory Distress Syndrome A syndrome characterized by progressive life-threatening RESPIRATORY INSUFFICIENCY in the absence of known LUNG DISEASES, usually following a systemic insult such as surgery or major TRAUMA. ARDS, Human,Acute Respiratory Distress Syndrome,Adult Respiratory Distress Syndrome,Pediatric Respiratory Distress Syndrome,Respiratory Distress Syndrome, Acute,Respiratory Distress Syndrome, Adult,Respiratory Distress Syndrome, Pediatric,Shock Lung,Distress Syndrome, Respiratory,Distress Syndromes, Respiratory,Human ARDS,Lung, Shock,Respiratory Distress Syndromes,Syndrome, Respiratory Distress
D001784 Blood Gas Analysis Measurement of oxygen and carbon dioxide in the blood. Analysis, Blood Gas,Analyses, Blood Gas,Blood Gas Analyses,Gas Analyses, Blood,Gas Analysis, Blood
D002245 Carbon Dioxide A colorless, odorless gas that can be formed by the body and is necessary for the respiration cycle of plants and animals. Carbonic Anhydride,Anhydride, Carbonic,Dioxide, Carbon
D002406 Catheterization, Peripheral Insertion of a catheter into a peripheral artery, vein, or airway for diagnostic or therapeutic purposes. Arterial Catheterization, Peripheral,Catheterization, Bronchial,Catheterization, Peripheral Arterial,Catheterization, Peripheral Venous,Peripheral Catheterization,Venous Catheterization, Peripheral,Bronchial Catheterization,PICC Line Catheterization,PICC Line Placement,PICC Placement,Peripheral Arterial Catheterization,Peripheral Venous Catheterization,Peripherally Inserted Central Catheter Line Insertion,Arterial Catheterizations, Peripheral,Bronchial Catheterizations,Catheterization, PICC Line,Catheterizations, Bronchial,Catheterizations, PICC Line,Catheterizations, Peripheral,Catheterizations, Peripheral Arterial,Catheterizations, Peripheral Venous,PICC Line Catheterizations,PICC Line Placements,PICC Placements,Peripheral Arterial Catheterizations,Peripheral Catheterizations,Peripheral Venous Catheterizations,Placement, PICC,Placement, PICC Line,Placements, PICC,Placements, PICC Line,Venous Catheterizations, Peripheral
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness

Related Publications

D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
October 1994, Masui. The Japanese journal of anesthesiology,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
December 1997, British journal of anaesthesia,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
December 1997, British journal of anaesthesia,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
April 1995, Critical care medicine,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
January 1994, Intensive care medicine,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
June 1999, Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
August 1996, Intensive care medicine,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
January 1994, Minerva anestesiologica,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
April 2004, Laboratory animals,
D Pappert, and R Rossaint, and K Lewandowski, and R Kuhlen, and H Gerlach, and K J Falke
March 1998, Canadian journal of anaesthesia = Journal canadien d'anesthesie,