Analysis of high-frequency signal-averaged ECG measurements. 1995

Q Xue, and B R Reddy, and T Aversano
Marquette Electronics, Inc. Milwaukee, Wisconsin 53223, USA.

Analysis of high frequency (150-250 Hz) in the signal-averaged electrocardiogram (SAECG) is one of the emerging methods for detecting vessel patency in acute myocardial infarction following thrombolytic therapy and angioplasty. Root-mean-square voltage (RMSV) of the filtered QRS has been used in earlier studies to detect reperfusion; however, previous analysis indicated that RMSV is sensitive to residual noise in the SAECG and errors in QRS delineation (onset/offset). A new measurement is proposed, high-frequency energy (HFQE), and the robustness of the RMSV and HFQE was evaluated for simulated errors in QRS delineation. In this study, two measures (RMSV and HFQE) were tested on 24 control subjects and 21 patients undergoing thrombolytic therapy. Results indicate that unfiltered QRS duration is more stable than filtered QRS duration for the control subjects and patients and that HFQE had less fluctuation than RMSV in thrombolytic therapy patients. In the control group, HFQE was sensitive to the amplitude variation of the filtered SAECG. Therefore, another new measurement is proposed high-frequency integral of absolute value (HFAV), for reducing the sensitivity to amplitude changes in the filtered SAECG. This new feature was tested on control subjects and was found to be more stable than HFQE. In the thrombolitic therapy group, HFAV provided similar information as HFQE. These three measurements-RMSV, HFQE, and HFAV-provide a comprehensive analysis of the high-frequency SAECG for detecting vessel patency and reocclusion. Relative merits of these measures need to be evaluated on a larger database of patients undergoing thrombolysis and angioplasty for acute myocardial infarction.

UI MeSH Term Description Entries
D009203 Myocardial Infarction NECROSIS of the MYOCARDIUM caused by an obstruction of the blood supply to the heart (CORONARY CIRCULATION). Cardiovascular Stroke,Heart Attack,Myocardial Infarct,Cardiovascular Strokes,Heart Attacks,Infarct, Myocardial,Infarction, Myocardial,Infarctions, Myocardial,Infarcts, Myocardial,Myocardial Infarctions,Myocardial Infarcts,Stroke, Cardiovascular,Strokes, Cardiovascular
D011336 Probability The study of chance processes or the relative frequency characterizing a chance process. Probabilities
D012008 Recurrence The return of a sign, symptom, or disease after a remission. Recrudescence,Relapse,Recrudescences,Recurrences,Relapses
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D012815 Signal Processing, Computer-Assisted Computer-assisted processing of electric, ultrasonic, or electronic signals to interpret function and activity. Digital Signal Processing,Signal Interpretation, Computer-Assisted,Signal Processing, Digital,Computer-Assisted Signal Interpretation,Computer-Assisted Signal Interpretations,Computer-Assisted Signal Processing,Interpretation, Computer-Assisted Signal,Interpretations, Computer-Assisted Signal,Signal Interpretation, Computer Assisted,Signal Interpretations, Computer-Assisted,Signal Processing, Computer Assisted
D014654 Vascular Patency The degree to which BLOOD VESSELS are not blocked or obstructed. Patency, Vascular,Patencies, Vascular,Vascular Patencies
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015906 Angioplasty, Balloon, Coronary Dilation of an occluded coronary artery (or arteries) by means of a balloon catheter to restore myocardial blood supply. Angioplasty, Coronary Balloon,Angioplasty, Transluminal, Percutaneous Coronary,Coronary Angioplasty, Transluminal Balloon,Percutaneous Transluminal Coronary Angioplasty,Balloon Dilation, Coronary Artery,Transluminal Coronary Balloon Dilation,Angioplasties, Coronary Balloon,Balloon Angioplasties, Coronary,Balloon Angioplasty, Coronary,Coronary Balloon Angioplasties,Coronary Balloon Angioplasty

Related Publications

Q Xue, and B R Reddy, and T Aversano
January 1992, Journal of electrocardiology,
Q Xue, and B R Reddy, and T Aversano
July 1993, Medical & biological engineering & computing,
Q Xue, and B R Reddy, and T Aversano
January 1995, Journal of electrocardiology,
Q Xue, and B R Reddy, and T Aversano
April 1992, Journal of electrocardiology,
Q Xue, and B R Reddy, and T Aversano
September 1993, European heart journal,
Q Xue, and B R Reddy, and T Aversano
July 1993, Medical & biological engineering & computing,
Q Xue, and B R Reddy, and T Aversano
August 1992, The Journal of the Association of Physicians of India,
Q Xue, and B R Reddy, and T Aversano
January 1995, Journal of electrocardiology,
Copied contents to your clipboard!