The effect of polyethylene glycol on the charcoal adsorption of chlorpromazine studied by ion selective electrode potentiometry. 1996

J Atta-Politou, and P E Macheras, and M A Koupparis
University of Athens, Panepistimiopolis, Greece.

BACKGROUND This investigation was undertaken to study: a) the adsorption characteristics of chlorpromazine to activated charcoal and its formulations Carbomix powder and Ultracarbon tablets at gastric pH; b) the effect on chlorpromazine adsorption of polyethylene glycol and its combination with electrolyte lavage solution; c) the effect of the order of addition of polyethylene glycol-electrolyte lavage solution. METHODS Ion selective electrode potentiometry, based on the selective, direct and continuous response of a chlorpromazine-ion selective electrode to the concentration of the free drug, was used. Successive additions of microvolumes of a chlorpromazine solution were made into a charcoal slurry in acidic medium of pH 1.2 with measurement of the chlorpromazine-ion selective electrode potential at equilibrium. RESULTS The maximum adsorption capacity values of activated charcoal, Carbomix and Ultracarbon, were 297, 563, and 382 mg/g respectively, while the affinity constant values were 40.2, 70.4, and 40.5 L/g, respectively. The adsorption of chlorpromazine to each of the Ultracarbon and Carbomix components was compared to the total adsorption of the formulations. The addition of polyethylene glycol-electrolyte lavage solution causes a slight desorption of chlorpromazine from activated charcoal at gastric pH, more pronounced when polyethylene glycol-electrolyte lavage solution follows the addition of activated charcoal, suggesting the possibility of a nonspecific binding of chlorpromazine to polyethylene glycol. The amount of chlorpromazine absorbed to Carbomix and Ultracarbon was not significantly affected at gastric pH by the presence of polyethylene glycol or polyethylene glycol-electrolyte lavage solution added either concurrently or sequentially to these formulations.

UI MeSH Term Description Entries
D011092 Polyethylene Glycols Polymers of ETHYLENE OXIDE and water, and their ethers. They vary in consistency from liquid to solid depending on the molecular weight indicated by a number following the name. They are used as SURFACTANTS, dispersing agents, solvents, ointment and suppository bases, vehicles, and tablet excipients. Some specific groups are NONOXYNOLS, OCTOXYNOLS, and POLOXAMERS. Macrogols,Polyoxyethylenes,Carbowax,Macrogol,Polyethylene Glycol,Polyethylene Oxide,Polyethyleneoxide,Polyglycol,Glycol, Polyethylene,Glycols, Polyethylene,Oxide, Polyethylene,Oxides, Polyethylene,Polyethylene Oxides,Polyethyleneoxides,Polyglycols,Polyoxyethylene
D011199 Potentiometry Solution titration in which the end point is read from the electrode-potential variations with the concentrations of potential determining ions. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed)
D002606 Charcoal An amorphous form of carbon prepared from the incomplete combustion of animal or vegetable matter, e.g., wood. The activated form of charcoal is used in the treatment of poisoning. (Grant & Hackh's Chemical Dictionary, 5th ed) Activated Charcoal,Actidose,Actidose-Aqua,Adsorba,Carbomix,Charbon,CharcoAid,CharcoCaps,Charcodote,Formocarbine,Insta-Char,Kohle-Compretten,Kohle-Hevert,Kohle-Pulvis,Kohle-Tabletten Boxo-Pharm,Liqui-Char,Norit,Ultracarbon,Charcoal, Activated
D002746 Chlorpromazine The prototypical phenothiazine antipsychotic drug. Like the other drugs in this class chlorpromazine's antipsychotic actions are thought to be due to long-term adaptation by the brain to blocking DOPAMINE RECEPTORS. Chlorpromazine has several other actions and therapeutic uses, including as an antiemetic and in the treatment of intractable hiccup. Aminazine,Chlorazine,Chlordelazine,Chlorpromazine Hydrochloride,Contomin,Fenactil,Largactil,Propaphenin,Thorazine,Hydrochloride, Chlorpromazine
D000327 Adsorption The adhesion of gases, liquids, or dissolved solids onto a surface. It includes adsorptive phenomena of bacteria and viruses onto surfaces as well. ABSORPTION into the substance may follow but not necessarily. Adsorptions
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor
D017736 Ion-Selective Electrodes Electrodes which can be used to measure the concentration of particular ions in cells, tissues, or solutions. Electrodes, Ion-Selective,Ion Selective Electrode,Ion-Sensitive Electrode,Ion-Sensitive Electrodes,Electrode, Ion Selective,Electrode, Ion-Selective,Electrode, Ion-Sensitive,Electrodes, Ion Selective,Electrodes, Ion-Sensitive,Ion Selective Electrodes,Ion Sensitive Electrode,Ion Sensitive Electrodes,Ion-Selective Electrode,Selective Electrode, Ion,Selective Electrodes, Ion

Related Publications

J Atta-Politou, and P E Macheras, and M A Koupparis
December 1980, Clinical chemistry,
J Atta-Politou, and P E Macheras, and M A Koupparis
March 1999, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences,
J Atta-Politou, and P E Macheras, and M A Koupparis
January 2001, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences,
J Atta-Politou, and P E Macheras, and M A Koupparis
February 2000, Journal of colloid and interface science,
J Atta-Politou, and P E Macheras, and M A Koupparis
August 2004, Protein and peptide letters,
Copied contents to your clipboard!