Reproducibility of echocardiographic estimates of left ventricular dimensions. 1977

M A Stefadouros, and M I Canedo

Although echocardiography is ideally suited for repetitive use on a patient for evaluation of left ventricular function, the value of this application is minimised by the uncertainty as to whether changes in left ventricular dimensions observed on a patient at different times or by different observers are real or result from the ultrasonic beam penetrating the left ventricle at different angles. Accordingly, an instrument was designed and constructed in our laboratory to improve the reproducibility of echocardiographic measurements of left ventricular dimensions. The instrument represents an orthogonal reference frame by means of which the spatial orientation of the ultrasonic beam relative to the chest is determined and reproduced in subsequent studies, while the point of entrance of the beam is marked on the chest wall. Using this instrument, left ventricular echograms were initially recorded on a group (I) of 23 subjects with or without heart disease and the study was repeated 8 hours to 49 (mean 7) days later by the same observer and also, in 16 cases, by an independent observer. The average values from 2 to 6 (mean 4) heart cycles were used for the left ventricular end-diastolic dimension (Dd), end-systolic (Ds) dimension, and their difference (delta D). Differences in all three variables between studies were random and statistically insignificant, never exceeding 3-5 mm for Dd or Ds, and 4 mm for deltaD. For comparison, left ventricular internal dimensions were also obtained in a seprate group (II) of 14 subjects by the standard method of using the mitral valve as an internal landmark, without the benefit of this instrument. All 14 subjects had the initial study repeated within 8 hours to 11 (mean 3-8) days later by the same and also by an independent observer. Though in the group as a whole there was no significant difference in left ventricular dimensions between studies, individual variations reached 11 mm for Dd, 9 mm for Ds, and 9 mm for deltaD, and the degree of scatter was significantly larger than in group I. This initial experience indicates that the use of this instrument improves the reproducibility and enhances the reliability of estimates of echocardiographic left ventricular dimensions and function on a patient examined at different times by the same or independent observers.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009206 Myocardium The muscle tissue of the HEART. It is composed of striated, involuntary muscle cells (MYOCYTES, CARDIAC) connected to form the contractile pump to generate blood flow. Muscle, Cardiac,Muscle, Heart,Cardiac Muscle,Myocardia,Cardiac Muscles,Heart Muscle,Heart Muscles,Muscles, Cardiac,Muscles, Heart
D002648 Child A person 6 to 12 years of age. An individual 2 to 5 years old is CHILD, PRESCHOOL. Children
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D005260 Female Females
D006331 Heart Diseases Pathological conditions involving the HEART including its structural and functional abnormalities. Cardiac Disorders,Heart Disorders,Cardiac Diseases,Cardiac Disease,Cardiac Disorder,Heart Disease,Heart Disorder
D006352 Heart Ventricles The lower right and left chambers of the heart. The right ventricle pumps venous BLOOD into the LUNGS and the left ventricle pumps oxygenated blood into the systemic arterial circulation. Cardiac Ventricle,Cardiac Ventricles,Heart Ventricle,Left Ventricle,Right Ventricle,Left Ventricles,Right Ventricles,Ventricle, Cardiac,Ventricle, Heart,Ventricle, Left,Ventricle, Right,Ventricles, Cardiac,Ventricles, Heart,Ventricles, Left,Ventricles, Right
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000293 Adolescent A person 13 to 18 years of age. Adolescence,Youth,Adolescents,Adolescents, Female,Adolescents, Male,Teenagers,Teens,Adolescent, Female,Adolescent, Male,Female Adolescent,Female Adolescents,Male Adolescent,Male Adolescents,Teen,Teenager,Youths

Related Publications

M A Stefadouros, and M I Canedo
February 1987, Hypertension (Dallas, Tex. : 1979),
M A Stefadouros, and M I Canedo
February 2012, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
M A Stefadouros, and M I Canedo
August 1972, The American journal of cardiology,
M A Stefadouros, and M I Canedo
August 1988, European heart journal,
M A Stefadouros, and M I Canedo
May 2001, American journal of physiology. Heart and circulatory physiology,
M A Stefadouros, and M I Canedo
April 1975, The American journal of cardiology,
M A Stefadouros, and M I Canedo
November 1976, British heart journal,
M A Stefadouros, and M I Canedo
October 1986, The Journal of the Association of Physicians of India,
Copied contents to your clipboard!