Sensitive flow-injection method with peroxyoxalate chemiluminescence detection combined with preparative high-performance liquid chromatography for determination of choline-containing phospholipids in human serum. 1996

M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
School of Pharmaceutical Sciences, Nagasaki University, Japan.

A sensitive and rapid flow-injection analysis (FIA) of total choline-containing phospholipids (PLs) and a selective FIA method for the class assay of choline-containing PLs combined with preparative HPLC were described. The FIA method is based on peroxyoxalate chemiluminescence (PO-CL) detection of hydrogen peroxide enzymatically formed from choline-containing PL. The linear standard curves were obtained up to 1 nmol/20-microliters injection (r > 0.999) with the detection limits of 1.3-1.6 pmol at a signal-to-noise ratio of 2. The total amounts of choline-containing PLs in human serum were ranged from 1.63 to 3.19 mg/ml. The HPLC separation of choline-containing PLs was achieved with an aminopropyl-modified silica gel column using a mixture of acetonitrile-methanol-10 mM ammonium phosphate buffer pH 5.8 as eluent. The eluate corresponding to each choline-containing PL was collected, evaporated, dissolved in 0.1% Triton X-100 aqueous solution, and then injected into FIA system. The FIA method combined with preparative HPLC was applied to the assay of human serum.

UI MeSH Term Description Entries
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D010070 Oxalates Derivatives of OXALIC ACID. Included under this heading are a broad variety of acid forms, salts, esters, and amides that are derived from the ethanedioic acid structure. Oxalate,Ethanedioic Acids,Oxalic Acids,Acids, Ethanedioic,Acids, Oxalic
D010743 Phospholipids Lipids containing one or more phosphate groups, particularly those derived from either glycerol (phosphoglycerides see GLYCEROPHOSPHOLIPIDS) or sphingosine (SPHINGOLIPIDS). They are polar lipids that are of great importance for the structure and function of cell membranes and are the most abundant of membrane lipids, although not stored in large amounts in the system. Phosphatides,Phospholipid
D002794 Choline A basic constituent of lecithin that is found in many plants and animal organs. It is important as a precursor of acetylcholine, as a methyl donor in various metabolic processes, and in lipid metabolism. Bursine,Fagine,Vidine,2-Hydroxy-N,N,N-trimethylethanaminium,Choline Bitartrate,Choline Chloride,Choline Citrate,Choline Hydroxide,Choline O-Sulfate,Bitartrate, Choline,Chloride, Choline,Choline O Sulfate,Citrate, Choline,Hydroxide, Choline,O-Sulfate, Choline
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D006863 Hydrogen-Ion Concentration The normality of a solution with respect to HYDROGEN ions; H+. It is related to acidity measurements in most cases by pH pH,Concentration, Hydrogen-Ion,Concentrations, Hydrogen-Ion,Hydrogen Ion Concentration,Hydrogen-Ion Concentrations
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity

Related Publications

M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
April 1982, Journal of biochemistry,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
November 2006, Biomedical chromatography : BMC,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
January 1992, Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
January 1996, Biomedical chromatography : BMC,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
February 1986, Analytical biochemistry,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
August 1982, Journal of chromatography,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
September 2007, Journal of chromatography. A,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
July 2012, Talanta,
M Wada, and K Nakashima, and N Kuroda, and S Akiyama, and K Imai
April 2007, Journal of pharmaceutical and biomedical analysis,
Copied contents to your clipboard!