Automated determination of dextromethorphan and its main metabolites in human plasma by high-performance liquid chromatography and column switching. 1996

S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
Department of Psychiatry, University of Mainz, Germany.

An automated column-switching technique coupled to isocratic high-performance liquid chromatography (HPLC) with fluorescence detection was developed for simultaneous determination of dextromethorphan and its three major metabolites, dextrorphan, hydroxymorphinan, and methoxymorphinan. After cleavage of conjugates by incubation with glucuronidasearylsulfatase at 37 degrees C for 15 h, plasma samples were injected directly into the HPLC system. Dextromethorphan and metabolites were retained on a cleanup column (10 x 4.6 mm internal diameter [ID]) filled with cyanopropyl (CN) material (Hypersil CPS, 10-microns article size) while interfering proteins and lipids were washed to waste. After column switching, the drugs were eluted from the cleanup column and separated on Spherisorb CN material (5-microns particle size, column size 250 x 4.6 mm ID). Fluorescence detection was carried out with an excitation wavelength of 220 nm and an emission wavelength of 305 nm. Sample cleanup and HPLC separation were completed within 20 min. Regression analyses found linearity (r > 0.99) between drug concentration and detector response over a wide range-5-220 ng/ml for dextromethorphan, 5-550 ng/ml for dextrorphan, 5-500 ng/ml for hydroxymorphinan, and 5-200 ng/ml for methoxymorphinan. The limit of quantification was approximately 5 ng/ml, and the recovery was > 90% for all compounds. At concentrations of 20-500 ng/ml, the intra- and interassay coefficients of variation ranged from 3.5 to 14.6% and from 7.0 to 14.0%, respectively. The method is suitable for in vivo phenotyping of CYP2D6 activity, which catalyzes the O-demethylation of dextromethorphan to dextrorphan, and is also applicable to pharmacokinetic studies in man.

UI MeSH Term Description Entries
D008297 Male Males
D010641 Phenotype The outward appearance of the individual. It is the product of interactions between genes, and between the GENOTYPE and the environment. Phenotypes
D011786 Quality Control A system for verifying and maintaining a desired level of quality in a product or process by careful planning, use of proper equipment, continued inspection, and corrective action as required. (Random House Unabridged Dictionary, 2d ed) Control, Quality,Controls, Quality,Quality Controls
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D003915 Dextromethorphan Methyl analog of DEXTRORPHAN that shows high affinity binding to several regions of the brain, including the medullary cough center. This compound is an NMDA receptor antagonist (RECEPTORS, N-METHYL-D-ASPARTATE) and acts as a non-competitive channel blocker. It is one of the widely used ANTITUSSIVES, and is also used to study the involvement of glutamate receptors in neurotoxicity. d-Methorphan,Delsym,Dextromethorphan Hydrobromide,Dextromethorphan Hydrobromide, (+-)-Isomer,Dextromethorphan Hydrobromide, Monohydrate,Dextromethorphan Hydrochloride,Dextromethorphan, (+-)-Isomer,Racemethorphan,Hydrobromide, Dextromethorphan,Hydrochloride, Dextromethorphan
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults

Related Publications

S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
October 1992, Clinical chemistry,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
March 1994, Journal of chromatography. B, Biomedical applications,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
January 1992, Journal of chromatography,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
January 1990, Methods in enzymology,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
August 1994, Therapeutic drug monitoring,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
April 1988, Journal of chromatography,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
September 1990, Journal of chromatography,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
September 2003, Biomedical chromatography : BMC,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
March 1988, Journal of chromatography,
S Härtter, and D Baier, and J Dingemanse, and G Ziegler, and C Hiemke
June 1999, Journal of chromatography. A,
Copied contents to your clipboard!