Augmented hyperventilation via normoxic helium breathing does not prevent exercise-induced hypoxemia. 1996

M J Buono, and R Maly
Department of Biology, San Diego State University, CA 92182, USA.

The purpose of this study was to determine if augmented hyperventilation produced via normoxic helium breathing would reduce exercise-induced hypoxemia (EIH). Seven highly trained endurance athletes with a mean maximum oxygen uptake of 65 ml.kg-1.min-1, performed two cycle ergometer tests to volitional exhaustion. During one of the tests the subjects breathed ambient air, while during the other they breathed normoxic helium (21% O2, 79% He). Mean maximum expired ventilation significantly (p < .05) increased from 139 L.min-1 during the ambient trial to 168 L.min-1 while breathing normoxic helium. Mean arterial oxygen saturation obtained at maximum exercise, however, was not significantly different for the two trials (ambient = 90%, helium = 89%). These results suggest that significantly augmenting exercise hyperventilation by 21% essentially had no effect on EIH in endurance athletes. Thus, the data do not support the hypothesis that inadequate hyperventilation is an important mechanism for arterial oxygen desaturation during graded exercise to exhaustion in highly trained individuals.

UI MeSH Term Description Entries
D006985 Hyperventilation A pulmonary ventilation rate faster than is metabolically necessary for the exchange of gases. It is the result of an increased frequency of breathing, an increased tidal volume, or a combination of both. It causes an excess intake of oxygen and the blowing off of carbon dioxide. Hyperventilations
D008297 Male Males
D008449 Maximal Expiratory Flow-Volume Curves Curves depicting MAXIMAL EXPIRATORY FLOW RATE, in liters/second, versus lung inflation, in liters or percentage of lung capacity, during a FORCED VITAL CAPACITY determination. Common abbreviation is MEFV. Maximal Expiratory Flow Volume Curves
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D010807 Physical Endurance The time span between the beginning of physical activity by an individual and the termination because of exhaustion. Endurance, Physical,Physical Stamina,Stamina, Physical
D011659 Pulmonary Gas Exchange The exchange of OXYGEN and CARBON DIOXIDE between alveolar air and pulmonary capillary blood that occurs across the BLOOD-AIR BARRIER. Exchange, Pulmonary Gas,Gas Exchange, Pulmonary
D012119 Respiration The act of breathing with the LUNGS, consisting of INHALATION, or the taking into the lungs of the ambient air, and of EXHALATION, or the expelling of the modified air which contains more CARBON DIOXIDE than the air taken in (Blakiston's Gould Medical Dictionary, 4th ed.). This does not include tissue respiration ( Breathing
D002245 Carbon Dioxide A colorless, odorless gas that can be formed by the body and is necessary for the respiration cycle of plants and animals. Carbonic Anhydride,Anhydride, Carbonic,Dioxide, Carbon
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests

Related Publications

M J Buono, and R Maly
January 1992, European journal of applied physiology and occupational physiology,
M J Buono, and R Maly
January 1980, European journal of applied physiology and occupational physiology,
M J Buono, and R Maly
August 1995, Journal of applied physiology (Bethesda, Md. : 1985),
M J Buono, and R Maly
January 1997, Artificial organs,
M J Buono, and R Maly
July 2002, Journal of applied physiology (Bethesda, Md. : 1985),
M J Buono, and R Maly
May 1995, Anesthesia and analgesia,
M J Buono, and R Maly
November 1994, Journal of applied physiology (Bethesda, Md. : 1985),
M J Buono, and R Maly
October 1983, British medical journal (Clinical research ed.),
Copied contents to your clipboard!