Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients. 1996

M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
Department of Emergency Medicine, University of Vienna, Austria.

OBJECTIVE To evaluate the accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients. METHODS Prospective data collection. METHODS Emergency department in a 2,000-bed hospital. METHODS Thirty-nine patients admitted to the emergency department requiring invasive arterial blood pressure monitoring were enrolled to the study protocol. METHODS Continuous noninvasive blood pressure measurement was performed on the middle phalanx of the second and third finger, using a test instrument which provides continuous arterial waveform display with the use of a finger cuff. Invasive mean arterial blood pressure measurement was done by cannulation of the radial artery and direct transduction of the systemic arterial pressure waveform. RESULTS Three thousand one hundred eighteen pairs of simultaneous finger cuff and intra-arterial blood pressure measurements were collected in 1-min intervals from 39 patients over a total of 51.8 hrs. The overall discrepancy between both measurements was 0.10 mm Hg. The standard deviation of the differences was +/- 5.02 mm Hg. The mean bias in patients treated with catecholamines was 0.01 mm Hg and was not different from the bias observed in patients without catecholamines (mean bias: 0.23 mm Hg; p > .22). Whereas 95% of all comparisons between finger cuff and intra-arterial measurement had a discrepancy < or = +/- 10 mm Hg, 4.7% had a discrepancy between +/- 10.1 to 15 mm Hg and 0.3% exhibited a discrepancy > +/- 15 mm Hg. In 29 (74%) patients, the duration of errors > 10 mm Hg was < or = 1 min. In seven (18%) patients, the duration of errors > 10 mm Hg was between 2 to 3 mins and in three (8%) patients, the errors lasted for > 3 mins. CONCLUSIONS Our data provide a guide to the accuracy and reliability of noninvasive finger blood pressure measurements in critically ill patients. Although most test instrument measurements were reliable, in 8% of all patients large discrepancies (> 10 mm Hg) between both measurements with a duration of > 3 mins were noted. Concerning the considerable risk for arterial cannulation, our preliminary data demonstrate that the test instrument (PORTAPRES, TNO Biomedical Instrumentation Research Unit; The Netherlands) is an advance in noninvasive monitoring of critically ill patients and may be useful in most emergency clinical settings.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D005260 Female Females
D005385 Fingers Four or five slender jointed digits in humans and primates, attached to each HAND. Finger
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D015924 Blood Pressure Monitors Devices for continuously measuring and displaying the arterial blood pressure. Monitors, Blood Pressure,Sphygmomanometers, Continuous,Blood Pressure Monitor,Continuous Sphygmomanometer,Continuous Sphygmomanometers,Monitor, Blood Pressure,Pressure Monitor, Blood,Pressure Monitors, Blood,Sphygmomanometer, Continuous
D016638 Critical Illness A disease or state in which death is possible or imminent. Critically Ill,Critical Illnesses,Illness, Critical,Illnesses, Critical

Related Publications

M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
March 2009, Anesthesia and analgesia,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
January 1987, Journal of clinical monitoring,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
January 2024, Journal of intensive care medicine,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
August 1992, American journal of hypertension,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
January 2022, Anaesthesiology intensive therapy,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
January 2019, Brazilian journal of anesthesiology (Elsevier),
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
March 2003, Critical care medicine,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
April 2011, Intensive care medicine,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
September 2014, Journal of diabetes science and technology,
M M Hirschl, and M Binder, and H Herkner, and A Bur, and M Brunner, and D Seidler, and H G Stühlinger, and A N Laggner
December 1991, Anaesthesia,
Copied contents to your clipboard!