Three manual immunoassays for the rapid detection of hepatitis B surface antigen. 1996

G J Finny, and R John, and P G Babu, and G Sridharan
Department of Clinical Virology, Christian Medical College Hospital, Vellore, Tamil Nadu, India.

We have evaluated 3 commercial test kits for the detection of hepatitis B surface antigen (HBsAg) which do not require elaborate instrumentation and are relatively inexpensive. These included the Immunocomb-II (Orgenics, Israel), Austragen latex agglutination (Span, India) and Daina Screen (Abbott, USA) tests. A panel of 98 sera tested by IMx HBsAg assay (Abbott, USA) were used to evaluate the tests. Sensitivities of 96.6%, 86.2% and 96.6%, and specificities of 95.7%, 94.2% and 100%, respectively, were obtained. We therefore recommend the Immunocomb-II or Daina Screen tests for HBsAg detection in small laboratories where facilities to conduct automated enzyme-linked immunosorbent assays are not available.

UI MeSH Term Description Entries
D007124 Immunoenzyme Techniques Immunologic techniques based on the use of: (1) enzyme-antibody conjugates; (2) enzyme-antigen conjugates; (3) antienzyme antibody followed by its homologous enzyme; or (4) enzyme-antienzyme complexes. These are used histologically for visualizing or labeling tissue specimens. Antibody Enzyme Technique, Unlabeled,Enzyme Immunoassay,Enzyme-Labeled Antibody Technique,Immunoassay, Enzyme,Immunoperoxidase Techniques,Peroxidase-Antiperoxidase Complex Technique,Peroxidase-Labeled Antibody Technique,Antibody Enzyme Technic, Unlabeled,Enzyme-Labeled Antibody Technic,Immunoenzyme Technics,Immunoperoxidase Technics,Peroxidase-Antiperoxidase Complex Technic,Peroxidase-Labeled Antibody Technic,Antibody Technic, Enzyme-Labeled,Antibody Technic, Peroxidase-Labeled,Antibody Technics, Enzyme-Labeled,Antibody Technics, Peroxidase-Labeled,Antibody Technique, Enzyme-Labeled,Antibody Technique, Peroxidase-Labeled,Antibody Techniques, Enzyme-Labeled,Antibody Techniques, Peroxidase-Labeled,Enzyme Immunoassays,Enzyme Labeled Antibody Technic,Enzyme Labeled Antibody Technique,Enzyme-Labeled Antibody Technics,Enzyme-Labeled Antibody Techniques,Immunoassays, Enzyme,Immunoenzyme Technic,Immunoenzyme Technique,Immunoperoxidase Technic,Immunoperoxidase Technique,Peroxidase Antiperoxidase Complex Technic,Peroxidase Antiperoxidase Complex Technique,Peroxidase Labeled Antibody Technic,Peroxidase Labeled Antibody Technique,Peroxidase-Antiperoxidase Complex Technics,Peroxidase-Antiperoxidase Complex Techniques,Peroxidase-Labeled Antibody Technics,Peroxidase-Labeled Antibody Techniques,Technic, Enzyme-Labeled Antibody,Technic, Immunoenzyme,Technic, Immunoperoxidase,Technic, Peroxidase-Antiperoxidase Complex,Technic, Peroxidase-Labeled Antibody,Technics, Enzyme-Labeled Antibody,Technics, Immunoenzyme,Technics, Immunoperoxidase,Technics, Peroxidase-Antiperoxidase Complex,Technics, Peroxidase-Labeled Antibody,Technique, Enzyme-Labeled Antibody,Technique, Immunoenzyme,Technique, Immunoperoxidase,Technique, Peroxidase-Antiperoxidase Complex,Technique, Peroxidase-Labeled Antibody,Techniques, Enzyme-Labeled Antibody,Techniques, Immunoenzyme,Techniques, Immunoperoxidase,Techniques, Peroxidase-Antiperoxidase Complex,Techniques, Peroxidase-Labeled Antibody
D007841 Latex Fixation Tests Passive agglutination tests in which antigen is adsorbed onto latex particles which then clump in the presence of antibody specific for the adsorbed antigen. (From Stedman, 26th ed) Latex Agglutination Tests,Agglutination Test, Latex,Agglutination Tests, Latex,Fixation Test, Latex,Fixation Tests, Latex,Latex Agglutination Test,Latex Fixation Test,Test, Latex Agglutination,Test, Latex Fixation,Tests, Latex Agglutination,Tests, Latex Fixation
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006514 Hepatitis B Surface Antigens Those hepatitis B antigens found on the surface of the Dane particle and on the 20 nm spherical and tubular particles. Several subspecificities of the surface antigen are known. These were formerly called the Australia antigen. Australia Antigen,HBsAg,Hepatitis B Surface Antigen,Antigen, Australia
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

G J Finny, and R John, and P G Babu, and G Sridharan
April 2022, Tropical doctor,
G J Finny, and R John, and P G Babu, and G Sridharan
January 1983, Journal of virological methods,
G J Finny, and R John, and P G Babu, and G Sridharan
August 2006, The Korean journal of laboratory medicine,
G J Finny, and R John, and P G Babu, and G Sridharan
November 2017, Zhonghua liu xing bing xue za zhi = Zhonghua liuxingbingxue zazhi,
G J Finny, and R John, and P G Babu, and G Sridharan
January 1978, Journal of medical virology,
G J Finny, and R John, and P G Babu, and G Sridharan
January 1978, Voprosy virusologii,
G J Finny, and R John, and P G Babu, and G Sridharan
December 2002, Journal of clinical microbiology,
G J Finny, and R John, and P G Babu, and G Sridharan
January 2000, Clinical laboratory,