Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography. 1996

I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
II Medical Clinic, University of Mainz, Germany.

The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes out of the 3D data set. The spatial position of the planes was indicated in a reference image. In the cross-sectional plane with the narrowest part of the leaflets the orifice area was measured by planimetry. For topographic information a 3D view down from the top of the left atrium was reconstructed. Measurements were compared to conventional transthoracic planimetry, to Doppler-echocardiographic pressure half time and to invasive data. The mean difference to transthoracic planimetry, pressure half time and to invasive measurements were 0.3 +/- 0.1 cm2, 0.2 +/- 0.1 cm2 and 0.1 +/- 0.1 cm2, respectively. Remarkable differences between the 3D- echocardiographic and the 2D- or Doppler- echocardiographic methods were observed in patients with severe calcification or aortic regurgitation. In 22% of the patients the 3D data set was not of diagnostic quality. New diagnostic information from a 3D view of the mitral valve could be obtained in 69% of the patients. Thus, although image quality is limited, 3D- echocardiography provides new topographic information in mitral valve stenosis. It allows the use of a new quantitative method, by which image plane positioning errors and flow-dependent calculation is avoided.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008946 Mitral Valve Stenosis Narrowing of the passage through the MITRAL VALVE due to FIBROSIS, and CALCINOSIS in the leaflets and chordal areas. This elevates the left atrial pressure which, in turn, raises pulmonary venous and capillary pressure leading to bouts of DYSPNEA and TACHYCARDIA during physical exertion. RHEUMATIC FEVER is its primary cause. Mitral Stenosis,Mitral Stenoses,Mitral Valve Stenoses,Stenoses, Mitral,Stenoses, Mitral Valve,Stenosis, Mitral,Stenosis, Mitral Valve,Valve Stenoses, Mitral,Valve Stenosis, Mitral
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D015150 Echocardiography, Doppler Measurement of intracardiac blood flow using an M-mode and/or two-dimensional (2-D) echocardiogram while simultaneously recording the spectrum of the audible Doppler signal (e.g., velocity, direction, amplitude, intensity, timing) reflected from the moving column of red blood cells. Doppler Echocardiography,Echocardiography, Continuous Doppler,Echocardiography, Two-Dimensional Doppler,2-D Doppler Echocardiography,2D Doppler Echocardiography,Continuous Doppler Echocardiography,Doppler Echocardiography, 2-D,Doppler Echocardiography, 2D,Doppler Echocardiography, Continuous,Doppler Echocardiography, Two-Dimensional,Echocardiography, 2-D Doppler,Echocardiography, 2D Doppler,Two-Dimensional Doppler Echocardiography,2 D Doppler Echocardiography,Doppler Echocardiography, 2 D,Doppler Echocardiography, Two Dimensional,Echocardiography, 2 D Doppler,Echocardiography, Two Dimensional Doppler,Two Dimensional Doppler Echocardiography
D015588 Observer Variation The failure by the observer to measure or identify a phenomenon accurately, which results in an error. Sources for this may be due to the observer's missing an abnormality, or to faulty technique resulting in incorrect test measurement, or to misinterpretation of the data. Two varieties are inter-observer variation (the amount observers vary from one another when reporting on the same material) and intra-observer variation (the amount one observer varies between observations when reporting more than once on the same material). Bias, Observer,Interobserver Variation,Intraobserver Variation,Observer Bias,Inter-Observer Variability,Inter-Observer Variation,Interobserver Variability,Intra-Observer Variability,Intra-Observer Variation,Intraobserver Variability,Inter Observer Variability,Inter Observer Variation,Inter-Observer Variabilities,Inter-Observer Variations,Interobserver Variabilities,Interobserver Variations,Intra Observer Variability,Intra Observer Variation,Intra-Observer Variabilities,Intra-Observer Variations,Intraobserver Variabilities,Intraobserver Variations,Observer Variations,Variabilities, Inter-Observer,Variabilities, Interobserver,Variabilities, Intra-Observer,Variabilities, Intraobserver,Variability, Inter-Observer,Variability, Interobserver,Variability, Intra-Observer,Variability, Intraobserver,Variation, Inter-Observer,Variation, Interobserver,Variation, Intra-Observer,Variation, Intraobserver,Variation, Observer,Variations, Inter-Observer,Variations, Interobserver,Variations, Intra-Observer,Variations, Intraobserver,Variations, Observer

Related Publications

I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
January 2019, Heart views : the official journal of the Gulf Heart Association,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
March 2020, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
August 2016, The Journal of cardiovascular surgery,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
October 2008, Chinese medical journal,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
September 2012, The Kaohsiung journal of medical sciences,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
July 2012, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
January 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
February 2013, The American journal of cardiology,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
January 2012, Texas Heart Institute journal,
I Kupferwasser, and S Mohr-Kahaly, and T Menzel, and M Spiecker, and G Dohmen, and E Mayer, and H Oelert, and R Erbel, and J Meyer
January 2012, Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese,
Copied contents to your clipboard!