Single-channel properties of swelling-activated anion conductance in rat inner medullary collecting duct cells. 1996

S H Boese, and R K Kinne, and F Wehner
Max-Planck-Institut für Molekulare Physiologie, Abteilung Epithelphysiologie, Dortmund, Germany.

Single-channel properties of the volume-activated outwardly rectifying Cl- conductance of rat IMCD cells were studied in primary cultures by means of the patch-clamp technique in the whole cell and in the outside-out configuration. Measurements were performed by noise analysis and in single-channel recordings during voltage-induced current inactivation and reactivation and in long-lasting experiments at constant membrane voltages. Unitary conductances could be defined for the voltage range of -100 to -50 mV and between +50 and +120 mV and chord conductances of 34.1 and 76.6 pS, respectively, can be calculated. The overall current-to-voltage relationship very much resembles that of the macroscopic Cl- conductance and the open probability of the activated channel is close to unity (Po = 0.98-0.99). The channel exhibits many similarities to volume-activated outwardly rectifying Cl- channels found in other systems although certain species differences do exist.

UI MeSH Term Description Entries
D007679 Kidney Medulla The internal portion of the kidney, consisting of striated conical masses, the renal pyramids, whose bases are adjacent to the cortex and whose apices form prominent papillae projecting into the lumen of the minor calyces. Kidney Papilla,Kidney Medullas,Kidney Papillas,Medulla, Kidney,Medullas, Kidney,Papilla, Kidney,Papillas, Kidney
D007685 Kidney Tubules, Collecting Straight tubes commencing in the radiate part of the kidney cortex where they receive the curved ends of the distal convoluted tubules. In the medulla the collecting tubules of each pyramid converge to join a central tube (duct of Bellini) which opens on the summit of the papilla. Kidney Collecting Ducts,Kidney Collecting Duct,Collecting Duct, Kidney,Collecting Ducts, Kidney
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D051381 Rats The common name for the genus Rattus. Rattus,Rats, Laboratory,Rats, Norway,Rattus norvegicus,Laboratory Rat,Laboratory Rats,Norway Rat,Norway Rats,Rat,Rat, Laboratory,Rat, Norway,norvegicus, Rattus
D018118 Chloride Channels Cell membrane glycoproteins that form channels to selectively pass chloride ions. Nonselective blockers include FENAMATES; ETHACRYNIC ACID; and TAMOXIFEN. CaCC,Calcium-Activated Chloride Channel,Chloride Ion Channel,Chlorine Channel,Ion Channels, Chloride,CaCCs,Calcium-Activated Chloride Channels,Chloride Channel,Chloride Ion Channels,Chlorine Channels,Ion Channel, Chloride,Calcium Activated Chloride Channel,Calcium Activated Chloride Channels,Channel, Calcium-Activated Chloride,Channel, Chloride,Channel, Chloride Ion,Channel, Chlorine,Channels, Calcium-Activated Chloride,Channels, Chloride,Channels, Chloride Ion,Channels, Chlorine,Chloride Channel, Calcium-Activated,Chloride Channels, Calcium-Activated
D018408 Patch-Clamp Techniques An electrophysiologic technique for studying cells, cell membranes, and occasionally isolated organelles. All patch-clamp methods rely on a very high-resistance seal between a micropipette and a membrane; the seal is usually attained by gentle suction. The four most common variants include on-cell patch, inside-out patch, outside-out patch, and whole-cell clamp. Patch-clamp methods are commonly used to voltage clamp, that is control the voltage across the membrane and measure current flow, but current-clamp methods, in which the current is controlled and the voltage is measured, are also used. Patch Clamp Technique,Patch-Clamp Technic,Patch-Clamp Technique,Voltage-Clamp Technic,Voltage-Clamp Technique,Voltage-Clamp Techniques,Whole-Cell Recording,Patch-Clamp Technics,Voltage-Clamp Technics,Clamp Technique, Patch,Clamp Techniques, Patch,Patch Clamp Technic,Patch Clamp Technics,Patch Clamp Techniques,Recording, Whole-Cell,Recordings, Whole-Cell,Technic, Patch-Clamp,Technic, Voltage-Clamp,Technics, Patch-Clamp,Technics, Voltage-Clamp,Technique, Patch Clamp,Technique, Patch-Clamp,Technique, Voltage-Clamp,Techniques, Patch Clamp,Techniques, Patch-Clamp,Techniques, Voltage-Clamp,Voltage Clamp Technic,Voltage Clamp Technics,Voltage Clamp Technique,Voltage Clamp Techniques,Whole Cell Recording,Whole-Cell Recordings

Related Publications

S H Boese, and R K Kinne, and F Wehner
September 2000, The Journal of membrane biology,
S H Boese, and R K Kinne, and F Wehner
June 2013, Journal of visualized experiments : JoVE,
S H Boese, and R K Kinne, and F Wehner
May 1987, Kidney international,
S H Boese, and R K Kinne, and F Wehner
August 1991, Journal of the American Society of Nephrology : JASN,
S H Boese, and R K Kinne, and F Wehner
April 2004, American journal of physiology. Renal physiology,
S H Boese, and R K Kinne, and F Wehner
January 2014, General physiology and biophysics,
S H Boese, and R K Kinne, and F Wehner
March 1998, The American journal of physiology,
S H Boese, and R K Kinne, and F Wehner
March 1998, In vitro cellular & developmental biology. Animal,
S H Boese, and R K Kinne, and F Wehner
January 1994, The American journal of physiology,
S H Boese, and R K Kinne, and F Wehner
December 1991, Steroids,
Copied contents to your clipboard!