Fatigue resistance and stress of wrought-steel wire clasps. 1996

P K Vallittu
Department of Prosthetics and Stomatognathic Physiology, University of Kuopio, Finland.

OBJECTIVE The objective of this study was to determine the fatigue resistance of wrought-steel wire clasps used for removable partial dentures. METHODS Five wrought-steel wires with cross-sectional diameters of 1.2, 1.1, 1.0, 0.9, and 0.8 mm were tested using a deflection fatigue test with deflections of 0.4 to 0.7 mm. The force and stress required to cause deflection was determined, as well as the number of loading cycles required to cause fatigue fracture. The fracture surfaces of the wrought-steel wire clasps were examined with a scanning electron microscope. RESULTS The number of loading cycles required to cause fatigue fracture increased with reduced deflection of the wrought wire (p < .005). To obtain fatigue resistance for loading cycles of over 10(6), the stress in the wrought-steel wire clasp should remain under 1.0 GPa. CONCLUSIONS These results suggest that to avoid fractures of wrought-steel wire clasps caused by bending fatigue, the stress on the clasp during its deflection should be taken into account.

UI MeSH Term Description Entries
D008422 Materials Testing The testing of materials and devices, especially those used for PROSTHESES AND IMPLANTS; SUTURES; TISSUE ADHESIVES; etc., for hardness, strength, durability, safety, efficacy, and biocompatibility. Biocompatibility Testing,Biocompatible Materials Testing,Hemocompatibility Testing,Testing, Biocompatible Materials,Testing, Hemocompatible Materials,Hemocompatibility Testings,Hemocompatible Materials Testing,Materials Testing, Biocompatible,Materials Testing, Hemocompatible,Testing, Biocompatibility,Testing, Hemocompatibility,Testing, Materials,Testings, Biocompatibility
D008855 Microscopy, Electron, Scanning Microscopy in which the object is examined directly by an electron beam scanning the specimen point-by-point. The image is constructed by detecting the products of specimen interactions that are projected above the plane of the sample, such as backscattered electrons. Although SCANNING TRANSMISSION ELECTRON MICROSCOPY also scans the specimen point by point with the electron beam, the image is constructed by detecting the electrons, or their interaction products that are transmitted through the sample plane, so that is a form of TRANSMISSION ELECTRON MICROSCOPY. Scanning Electron Microscopy,Electron Scanning Microscopy,Electron Microscopies, Scanning,Electron Microscopy, Scanning,Electron Scanning Microscopies,Microscopies, Electron Scanning,Microscopies, Scanning Electron,Microscopy, Electron Scanning,Microscopy, Scanning Electron,Scanning Electron Microscopies,Scanning Microscopies, Electron,Scanning Microscopy, Electron
D003722 Dental Alloys A mixture of metallic elements or compounds with other metallic or metalloid elements in varying proportions for use in restorative or prosthetic dentistry. Alloy, Dental,Alloys, Dental,Dental Alloy
D003799 Dental Stress Analysis The description and measurement of the various factors that produce physical stress upon dental restorations, prostheses, or appliances, materials associated with them, or the natural oral structures. Analyses, Dental Stress,Analysis, Dental Stress,Stress Analyses, Dental,Stress Analysis, Dental,Dental Stress Analyses
D003832 Denture, Partial, Removable A partial denture designed and constructed to be removed readily from the mouth. Removable Partial Denture,Denture, Removable Partial,Dentures, Removable Partial,Partial Denture, Removable,Partial Dentures, Removable,Removable Partial Dentures
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D000704 Analysis of Variance A statistical technique that isolates and assesses the contributions of categorical independent variables to variation in the mean of a continuous dependent variable. ANOVA,Analysis, Variance,Variance Analysis,Analyses, Variance,Variance Analyses
D013193 Stainless Steel Stainless steel. A steel containing Ni, Cr, or both. It does not tarnish on exposure and is used in corrosive environments. (Grant & Hack's Chemical Dictionary, 5th ed) Stainless Steels,Steel, Stainless,Steels, Stainless
D013314 Stress, Mechanical A purely physical condition which exists within any material because of strain or deformation by external forces or by non-uniform thermal expansion; expressed quantitatively in units of force per unit area. Mechanical Stress,Mechanical Stresses,Stresses, Mechanical
D016734 Dental Clasps Metal devices for fastening together two or more parts of dental prostheses for stabilizing or retaining them by attachment to abutment teeth. For a precision attachment for a partial denture DENTURE PRECISION ATTACHMENT is available. Denture Clasps,Clasp, Dental,Clasps, Dental,Dental Clasp,Clasp, Denture,Clasps, Denture,Denture Clasp

Related Publications

P K Vallittu
March 2008, Kokubyo Gakkai zasshi. The Journal of the Stomatological Society, Japan,
P K Vallittu
March 1981, The Journal of prosthetic dentistry,
P K Vallittu
February 1986, The Journal of prosthetic dentistry,
P K Vallittu
August 1990, The Journal of prosthetic dentistry,
P K Vallittu
November 2008, Dental materials : official publication of the Academy of Dental Materials,
P K Vallittu
April 1983, The Journal of prosthetic dentistry,
P K Vallittu
December 1992, The Journal of Osaka University Dental School,
P K Vallittu
December 1992, The Journal of Osaka University Dental School,
P K Vallittu
January 2013, Acta of bioengineering and biomechanics,
Copied contents to your clipboard!