Measurements and Monte Carlo simulations of the fluence and dose characteristics of microplanar photon beams. 1996

F Z Company, and B J Allen
Department of Physics, University of Western Sydney Nepean, Kingswood, NSW Australia.

The lateral absorbed dose, depth dose and photon fluence in a water phantom of a single microplanar beam is investigated using the Monte Carlo method. To validate the calculated axial and scattered photon fluence, an experiment is carried out using a NaI(TI) detector and 20 mCi Cd-109 source at energies of 22 keV and 88 keV. A 150 microns collimator is used to produce the microplanar beam, and the integrated scattered photon fluence is measured over 2.5 microns increments. The axial (depth) photon fluence is in good agreement with the calculated results. The scattered (lateral) photon fluence results agree to within two standard deviations.

UI MeSH Term Description Entries
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D011879 Radiotherapy Dosage The total amount of radiation absorbed by tissues as a result of radiotherapy. Dosage, Radiotherapy,Dosages, Radiotherapy,Radiotherapy Dosages
D002106 Cadmium Radioisotopes Unstable isotopes of cadmium that decay or disintegrate emitting radiation. Cd atoms with atomic weights 103-105, 107, 109, 115, and 117-119 are radioactive cadmium isotopes. Radioisotopes, Cadmium
D015233 Models, Statistical Statistical formulations or analyses which, when applied to data and found to fit the data, are then used to verify the assumptions and parameters used in the analysis. Examples of statistical models are the linear model, binomial model, polynomial model, two-parameter model, etc. Probabilistic Models,Statistical Models,Two-Parameter Models,Model, Statistical,Models, Binomial,Models, Polynomial,Statistical Model,Binomial Model,Binomial Models,Model, Binomial,Model, Polynomial,Model, Probabilistic,Model, Two-Parameter,Models, Probabilistic,Models, Two-Parameter,Polynomial Model,Polynomial Models,Probabilistic Model,Two Parameter Models,Two-Parameter Model
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

F Z Company, and B J Allen
October 2015, Journal of biomedical optics,
F Z Company, and B J Allen
March 2003, Medical physics,
F Z Company, and B J Allen
July 2005, Physics in medicine and biology,
F Z Company, and B J Allen
July 1999, Physics in medicine and biology,
F Z Company, and B J Allen
August 2019, Zeitschrift fur medizinische Physik,
F Z Company, and B J Allen
June 1998, Medical physics,
F Z Company, and B J Allen
November 2003, Physics in medicine and biology,
F Z Company, and B J Allen
January 1998, Physics in medicine and biology,
Copied contents to your clipboard!