Movement of pulmonary artery catheters. 1996

M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
Department of Anesthesia and Intensive Care, Aarhus University Hospital, Denmark.

Intraluminal movements of pulmonary artery catheters are seldom considered, although they may have a significant impact on flow measurement and safety. The purpose of this study was to document the movements of these catheters within the heart cycle, and to establish whether any patterns existed. We analyzed two-dimensional real time echocardiography cross-sectional images of the human pulmonary artery in 20 patients, plotting the position of the intra-arterial catheter frame-by-frame onto a standardized template. We found that movement of the catheter within the pulmonary artery occurred in a seemingly random pattern. There was no movement pattern to the inferior right of the vessel, an area known to have complex velocity profiles and erroneous velocity measurements. The catheter moved substantially throughout the heart cycle, occasionally quite close to the vessel wall. We observed significant movement of the pulmonary artery catheter throughout the heart cycle, without any predictable pattern. Although we did not specifically investigate the effect of these movements on cardiac output, they imply that intra-arterial Doppler flow measurements from the pulmonary artery may be inaccurate, since a stable catheter position, and hence, a sample volume, cannot be ensured. Further speculation can be made on the implications of these movements in regard to thermodilution cardiac output and safety.

UI MeSH Term Description Entries
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009038 Motion Physical motion, i.e., a change in position of a body or subject as a result of an external force. It is distinguished from MOVEMENT, a process resulting from biological activity. Motions
D011651 Pulmonary Artery The short wide vessel arising from the conus arteriosus of the right ventricle and conveying unaerated blood to the lungs. Arteries, Pulmonary,Artery, Pulmonary,Pulmonary Arteries
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002407 Catheterization, Swan-Ganz Placement of a balloon-tipped catheter into the pulmonary artery through the antecubital, subclavian, and sometimes the femoral vein. It is used to measure pulmonary artery pressure and pulmonary artery wedge pressure which reflects left atrial pressure and left ventricular end-diastolic pressure. The catheter is threaded into the right atrium, the balloon is inflated and the catheter follows the blood flow through the tricuspid valve into the right ventricle and out into the pulmonary artery. Catheterization, Pulmonary Artery,Swan-Ganz Catheterization,Pulmonary Artery Catheterization,Artery Catheterization, Pulmonary,Artery Catheterizations, Pulmonary,Catheterization, Swan Ganz,Catheterizations, Pulmonary Artery,Pulmonary Artery Catheterizations,Swan Ganz Catheterization
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D004869 Equipment Safety Freedom of equipment from actual or potential hazards. Device Safety,Hazards, Equipment,Medical Device Safety,Safety, Equipment,Device Safety, Medical,Safety, Medical Device,Equipment Hazard,Equipment Hazards,Hazard, Equipment,Safety, Device
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly

Related Publications

M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
July 2011, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
July 1975, The Alumni magazine,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
May 1988, Chest,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
May 1991, JAMA,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
November 2006, BMJ (Clinical research ed.),
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
February 1987, RN,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
October 1989, Critical care nurse,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
January 1987, Intensive care medicine,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
April 1990, Critical care medicine,
M S Chew, and E Sloth, and M Veien, and K V Jensen, and H H Kure, and J M Hasenkam
September 2003, Anesthesia and analgesia,
Copied contents to your clipboard!