[Safety rules for patients with artificial cardiac pacemaker]. 1996

R Costa, and M I Leão, and L V Décourt
Instituto de Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo.

The recent progress in cardiac pacing increased the usefulness of artificial pacemakers. The initial purpose of avoiding Stokes-Adams attacks, was changed by a complex way to completely give back the physiologic response of cardiac rate and atrioventricular synchronism. However, this process forced the patients to take care of their pacemakers, and to spend more time in follow-up procedures. Additionally, the pacemakers became more vulnerable to environmental and hospital interferences. Basic rules, for all patients, are described in this paper, in order to improve their quality of life. Follow-up procedures are related in detail. It is described how programmed electronic evaluations can contribute to avoid complications, to detect subclinic problems and to improve the patient's haemodynamics and physical capacity. It shows also how to use complementary examinations, like thoracic X-rays, exercise testing and Holter monitoring to optimize the cardiac pacing system. Interferences in pacemakers are focused with special attention to myo-potentials, environmental electromagnetic fields, and damage to system owing to medical procedures, like therapeutic radiation, defibrillation and electrocauterization. The approach to infective processes in pacemakers gives special emphasis to prevention of direct surgical contamination, erosion of the skin, and haematogenic dissemination of distant infective focus.

UI MeSH Term Description Entries
D007239 Infections Invasion of the host organism by microorganisms or their toxins or by parasites that can cause pathological conditions or diseases. Infection,Infection and Infestation,Infections and Infestations,Infestation and Infection,Infestations and Infections
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D010353 Patient Education as Topic The teaching or training of patients concerning their own health needs. Education of Patients,Education, Patient,Patient Education
D011182 Postoperative Care The period of care beginning when the patient is removed from surgery and aimed at meeting the patient's psychological and physical needs directly after surgery. (From Dictionary of Health Services Management, 2d ed) Care, Postoperative,Postoperative Procedures,Procedures, Postoperative,Postoperative Procedure,Procedure, Postoperative
D011788 Quality of Life A generic concept reflecting concern with the modification and enhancement of life attributes, e.g., physical, political, moral, social environment as well as health and disease. HRQOL,Health-Related Quality Of Life,Life Quality,Health Related Quality Of Life
D011830 Radiation Effects The effects of ionizing and nonionizing radiation upon living organisms, organs and tissues, and their constituents, and upon physiologic processes. It includes the effect of irradiation on food, drugs, and chemicals. Effects, Radiation,Effect, Radiation,Radiation Effect
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004560 Electricity The physical effects involving the presence of electric charges at rest and in motion.
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup

Related Publications

R Costa, and M I Leão, and L V Décourt
January 1976, Revista espanola de cardiologia,
R Costa, and M I Leão, and L V Décourt
November 2023, Acta Cardiologica Sinica,
R Costa, and M I Leão, and L V Décourt
January 1970, Giornale italiano di chirurgia,
R Costa, and M I Leão, and L V Décourt
May 1971, American heart journal,
R Costa, and M I Leão, and L V Décourt
November 1983, Minerva cardioangiologica,
R Costa, and M I Leão, and L V Décourt
December 1987, Arquivos brasileiros de cardiologia,
R Costa, and M I Leão, and L V Décourt
December 1969, Japanese circulation journal,
R Costa, and M I Leão, and L V Décourt
December 1964, California medicine,
R Costa, and M I Leão, and L V Décourt
November 1982, Pacing and clinical electrophysiology : PACE,
R Costa, and M I Leão, and L V Décourt
December 1969, Japanese circulation journal,