Pulsatile ocular blood flow measurements in healthy eyes: reproducibility and reference values. 1997

Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
St. Paul's Eye Unit, Liverpool, England.

OBJECTIVE To determine the reproducibility and the normal reference range of pulsatile ocular blood flow (POBF) values in healthy subjects using the Ocular Blood Flow Tonograph (OBF Laboratories, UK Ltd., Wiltshire, England). METHODS Pulsatile ocular blood flow was measured in one eye of each of 83 patients. Coefficient of reliability was determined by calculation of intraclass correlation coefficient via one-way analysis of variance. Mean difference between measurements was calculated for bias and first exposure effects. Pulsatile ocular blood flow from 163 healthy individuals were analyzed to determine the distribution, mean, standard deviation (SD), range, and the 5th and 95th percentile values. The influence of age, blood pressure, pulse rate, and intraocular pressure on pulsatile ocular blood flow was determined by regression analysis. RESULTS Reliability coefficient for pulsatile ocular blood flow values ranging from 290 microliters/min to 2,196 microliters/min was 0.92. Variation in bias and first exposure effect were not significant. Pulsatile ocular blood flow values were normally distributed. Mean values were 669.90 +/- 233.0 microliters/min in men and 841.90 +/- 254.6 microliters/min in women. Fifth and ninety-fifth percentile values were 364.75 microliters/min and 1,266.10 microliters/min in men and 397.18 microliters/min and 1,346.10 microliters/min in women. Pulsatile ocular blood flow was significantly influenced by pulse rate. CONCLUSIONS This study confirms the reliability of the Ocular Blood Flow Tonograph in repeated measurements of POBF within individuals over short time intervals. The high interindividual variation in POBF may invalidate comparison of POBF between individuals, and the wide range of normal values may limit the value of using a low POBF as a possible indicator of disease.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011673 Pulsatile Flow Rhythmic, intermittent propagation of a fluid through a BLOOD VESSEL or piping system, in contrast to constant, smooth propagation, which produces laminar flow. Flow, Pulsating,Perfusion, Pulsatile,Flow, Pulsatile,Flows, Pulsatile,Flows, Pulsating,Perfusions, Pulsatile,Pulsatile Flows,Pulsatile Perfusion,Pulsatile Perfusions,Pulsating Flow,Pulsating Flows
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D005123 Eye The organ of sight constituting a pair of globular organs made up of a three-layered roughly spherical structure specialized for receiving and responding to light. Eyes
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults

Related Publications

Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
June 1995, Journal of glaucoma,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
November 2010, Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
March 2008, Korean journal of ophthalmology : KJO,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
May 1994, Survey of ophthalmology,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
January 1997, Eye (London, England),
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
May 1994, Survey of ophthalmology,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
September 2003, American journal of ophthalmology,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
July 1998, The British journal of ophthalmology,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
May 1994, Survey of ophthalmology,
Y C Yang, and M F Hulbert, and M Batterbury, and L G Clearkin
January 2005, European journal of ophthalmology,
Copied contents to your clipboard!