Chronic animal experiment with magnetically suspended centrifugal pump. 1997

T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
Department of Cardiovascular Surgery, Kyoto University, Japan.

We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using sheep. The flow rates ranged from 2.5-5.5 L/min. The sheep that lived the longest (46 days) died of an embolism as a result of the thrombus in the pump. No thrombus formation was observed in other pumps. Plasma free hemoglobin levels ranged from 9 to 18 mg/dl, which led to the conclusion that the hemolysis level remained within an acceptable range. Two driving modes were compared. The slope of the pressure-flow relationship plot under a constant motor current mode was steeper than that under a constant rotational speed mode, and thus, the flow fluctuation decreased. In conclusion, the MSCP is durable for more than a month at the current stage of development and is a promising device for long-term ventricular assist.

UI MeSH Term Description Entries
D011673 Pulsatile Flow Rhythmic, intermittent propagation of a fluid through a BLOOD VESSEL or piping system, in contrast to constant, smooth propagation, which produces laminar flow. Flow, Pulsating,Perfusion, Pulsatile,Flow, Pulsatile,Flows, Pulsatile,Flows, Pulsating,Perfusions, Pulsatile,Pulsatile Flows,Pulsatile Perfusion,Pulsatile Perfusions,Pulsating Flow,Pulsating Flows
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D002407 Catheterization, Swan-Ganz Placement of a balloon-tipped catheter into the pulmonary artery through the antecubital, subclavian, and sometimes the femoral vein. It is used to measure pulmonary artery pressure and pulmonary artery wedge pressure which reflects left atrial pressure and left ventricular end-diastolic pressure. The catheter is threaded into the right atrium, the balloon is inflated and the catheter follows the blood flow through the tricuspid valve into the right ventricle and out into the pulmonary artery. Catheterization, Pulmonary Artery,Swan-Ganz Catheterization,Pulmonary Artery Catheterization,Artery Catheterization, Pulmonary,Artery Catheterizations, Pulmonary,Catheterization, Swan Ganz,Catheterizations, Pulmonary Artery,Pulmonary Artery Catheterizations,Swan Ganz Catheterization
D002498 Centrifugation Process of using a rotating machine to generate centrifugal force to separate substances of different densities, remove moisture, or simulate gravitational effects. It employs a large motor-driven apparatus with a long arm, at the end of which human and animal subjects, biological specimens, or equipment can be revolved and rotated at various speeds to study gravitational effects. (From Websters, 10th ed; McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed)
D004389 Durable Medical Equipment Devices which are very resistant to wear and may be used over a long period of time. They include items such as wheelchairs, hospital beds, artificial limbs, etc. Equipment, Medical, Durable,Equipment, Durable Medical,Medical Equipment, Durable
D004574 Electromagnetic Fields Fields representing the joint interplay of electric and magnetic forces. Electromagnetic Field,Field, Electromagnetic,Fields, Electromagnetic
D006353 Heart-Assist Devices Small pumps, often implantable, designed for temporarily assisting the heart, usually the LEFT VENTRICLE, to pump blood. They consist of a pumping chamber and a power source, which may be partially or totally external to the body and activated by electromagnetic motors. Artificial Ventricle,Heart Assist Device,Heart Ventricle, Artificial,Pumps, Heart-Assist,Vascular-Assist Device,Vascular-Assist Devices,Ventricle-Assist Device,Ventricular Assist Device,Artificial Heart Ventricle,Artificial Heart Ventricles,Artificial Ventricles,Assist Device, Heart,Assist Device, Ventricular,Assist Devices, Heart,Assist Devices, Ventricular,Device, Heart Assist,Device, Heart-Assist,Device, Vascular-Assist,Device, Ventricle-Assist,Device, Ventricular Assist,Devices, Heart Assist,Devices, Heart-Assist,Devices, Vascular-Assist,Devices, Ventricle-Assist,Devices, Ventricular Assist,Heart Assist Devices,Heart Ventricles, Artificial,Heart-Assist Device,Heart-Assist Pump,Heart-Assist Pumps,Pump, Heart-Assist,Pumps, Heart Assist,Vascular Assist Device,Vascular Assist Devices,Ventricle Assist Device,Ventricle, Artificial,Ventricle, Artificial Heart,Ventricle-Assist Devices,Ventricles, Artificial,Ventricles, Artificial Heart,Ventricular Assist Devices
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic
D006454 Hemoglobins The oxygen-carrying proteins of ERYTHROCYTES. They are found in all vertebrates and some invertebrates. The number of globin subunits in the hemoglobin quaternary structure differs between species. Structures range from monomeric to a variety of multimeric arrangements. Eryhem,Ferrous Hemoglobin,Hemoglobin,Hemoglobin, Ferrous
D006461 Hemolysis The destruction of ERYTHROCYTES by many different causal agents such as antibodies, bacteria, chemicals, temperature, and changes in tonicity. Haemolysis,Extravascular Hemolysis,Intravascular Hemolysis,Extravascular Hemolyses,Haemolyses,Hemolyses, Extravascular,Hemolyses, Intravascular,Hemolysis, Extravascular,Hemolysis, Intravascular,Intravascular Hemolyses

Related Publications

T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
January 1998, ASAIO journal (American Society for Artificial Internal Organs : 1992),
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
June 1992, Artificial organs,
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
January 2002, ASAIO journal (American Society for Artificial Internal Organs : 1992),
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
January 2005, ASAIO journal (American Society for Artificial Internal Organs : 1992),
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
July 2003, Artificial organs,
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
May 1996, Artificial organs,
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
June 1996, Artificial organs,
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
March 2021, Perfusion,
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
July 1995, Artificial organs,
T Yamada, and K Nishimura, and C H Park, and S Kono, and S Yuasa, and T Tsukiya, and T Akamatsu, and K Matsuda, and T Ban
July 1995, Artificial organs,
Copied contents to your clipboard!