Coronary stenting with the half (disarticulated) Palmaz-Schatz stent: immediate results and six-month follow-up. 1997

A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
Istituto di Malattie dell'Apparato Cardiovascolare di Bologna, Italy.

Coronary stenting with the half disarticulated Palmaz-Schatz stent is particularly suitable for ostial stenoses, diaphragm stenoses, stenoses distal to tortuous segments or coronary bends and localized dissections after balloon angioplasty. Nevertheless very few data regarding the half stent exist and follow-up data are nonexistent. From January of 1994 to December of 1995 a total of 207 half stents were implanted in 175 patients. Most patients had stable or unstable angina and in the majority of cases the stent was implanted due to localized dissection or to suboptimal result. The procedural success rate was 98%. After stent implantation, 82 patients were treated with acetylsalicylic acid (ASA) and oral anticoagulant (group A), whereas 93 were treated with ASA and ticlopidine (group B). Seven patients had subacute thrombosis (5, group A; 2, group B), and six patients had major bleeding (5, group A; 1, group B). Overall, patients in group A had more cardiovascular complications than patients in group B (10, group A; 3, group B; p = 0.047). After 6-mo follow-up, 1 patient had died and 27 patients had symptoms of angina (16%). Thirteen patients underwent a second PTCA (7%) and four patients (2%) were referred for coronary artery bypass. In conclusion, coronary stenting with half Palmaz-Schatz stent appears to be a safe and effective procedure. In selected cases, the half Palmaz-Schatz stent is easier to handle than the complete stent, it is associated with a low rate of clinical restenosis, and it lowers procedural costs.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011859 Radiography Examination of any part of the body for diagnostic purposes by means of X-RAYS or GAMMA RAYS, recording the image on a sensitized surface (such as photographic film). Radiology, Diagnostic X-Ray,Roentgenography,X-Ray, Diagnostic,Diagnostic X-Ray,Diagnostic X-Ray Radiology,X-Ray Radiology, Diagnostic,Diagnostic X Ray,Diagnostic X Ray Radiology,Diagnostic X-Rays,Radiology, Diagnostic X Ray,X Ray Radiology, Diagnostic,X Ray, Diagnostic,X-Rays, Diagnostic
D011877 Radionuclide Imaging The production of an image obtained by cameras that detect the radioactive emissions of an injected radionuclide as it has distributed differentially throughout tissues in the body. The image obtained from a moving detector is called a scan, while the image obtained from a stationary camera device is called a scintiphotograph. Gamma Camera Imaging,Radioisotope Scanning,Scanning, Radioisotope,Scintigraphy,Scintiphotography,Imaging, Gamma Camera,Imaging, Radionuclide
D012008 Recurrence The return of a sign, symptom, or disease after a remission. Recrudescence,Relapse,Recrudescences,Recurrences,Relapses
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup

Related Publications

A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
February 1995, Catheterization and cardiovascular diagnosis,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
January 1995, Indian heart journal,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
April 1992, Catheterization and cardiovascular diagnosis,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
December 1994, Catheterization and cardiovascular diagnosis,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
September 1999, The American journal of cardiology,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
November 1996, Cardiologia (Rome, Italy),
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
November 1997, Catheterization and cardiovascular diagnosis,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
April 1996, Journal of the American College of Cardiology,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
July 1995, The American journal of cardiology,
A Marzocchi, and G Piovaccari, and C Marrozzini, and P Ortolani, and T Palmerini, and A Branzi, and B Magnani
February 1996, Circulation,
Copied contents to your clipboard!