Radiologic placement of subcutaneous infusion chest ports for long-term central venous access. 1997

B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
Department of Radiology, University of Chicago Hospitals, IL 60637, USA.

OBJECTIVE The technical success and complications associated with radiologic placement of subcutaneous implantable chest ports for long-term central venous access were evaluated. METHODS Between May 1, 1996, and December 31, 1996, 80 chest ports were placed in 80 consecutive patients using the right internal jugular vein as the preferred access route. All procedures occurred in interventional radiology suites with patients receiving conscious sedation. Both sonography and fluoroscopy were used for venipuncture and to guide port insertion. Follow-up was obtained by the clinical service and by performing chart reviews electronically. RESULTS Technical success was 100%, and follow-up was obtained in all patients. One procedural complication occurred that was unrelated to actual catheter placement. Mean catheter use was 155 days (total, 12,168 days; range, 18-303 days). Confirmed catheter-related infection rate was 3%, or 0.016 per 100 access days; symptomatic catheter-related central venous thrombosis rate was 1%, or 0.008 per 100 access days; and 5% of catheters were removed prematurely. No instances of hematoma formation, catheter tip migration or malposition, symptomatic air embolism, spontaneous catheter fracture, or pneumothorax were found. CONCLUSIONS With the benefit of both sonographic and fluoroscopic guidance, subcutaneous implantable chest ports can be inserted by radiologists with equal or lower complication rates than those reported in surgical series. Image-guided insertion of chest ports should replace rather than supplement unguided placement.

UI MeSH Term Description Entries
D007601 Jugular Veins Veins in the neck which drain the brain, face, and neck into the brachiocephalic or subclavian veins. Jugular Vein,Vein, Jugular,Veins, Jugular
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D002405 Catheterization, Central Venous Placement of an intravenous CATHETER in the subclavian, jugular, or other central vein. Central Venous Catheterization,Venous Catheterization, Central,Catheterization, Central,Central Catheterization,Catheterizations, Central,Catheterizations, Central Venous,Central Catheterizations,Central Venous Catheterizations,Venous Catheterizations, Central
D002408 Catheters, Indwelling Catheters designed to be left within an organ or passage for an extended period of time. Implantable Catheters,In-Dwelling Catheters,Catheter, In-Dwelling,Catheter, Indwelling,Catheters, In-Dwelling,In Dwelling Catheters,In-Dwelling Catheter,Indwelling Catheter,Indwelling Catheters
D005260 Female Females
D005471 Fluoroscopy Production of an image when x-rays strike a fluorescent screen. Fluoroscopies
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013350 Subclavian Vein The continuation of the axillary vein which follows the subclavian artery and then joins the internal jugular vein to form the brachiocephalic vein. Subclavian Veins,Vein, Subclavian,Veins, Subclavian

Related Publications

B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
July 1998, AJR. American journal of roentgenology,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
July 1992, Radiology,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
January 1995, Journal of vascular and interventional radiology : JVIR,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
August 1993, AJR. American journal of roentgenology,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
October 1998, Diagnostic imaging,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
January 1992, Acta haematologica Polonica,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
January 1993, Journal of vascular and interventional radiology : JVIR,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
February 1995, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
January 1988, Langenbecks Archiv fur Chirurgie,
B Funaki, and G X Szymski, and C A Hackworth, and J D Rosenblum, and R Burke, and T Chang, and J A Leef
July 1990, Radiology,
Copied contents to your clipboard!