Long-term evaluation of bone-titanium interface in rat tibiae using light microscopy, transmission electron microscopy, and image processing. 1997

F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
Prosthetic Dentistry II, Faculty of Dentistry, Kyushu University, Fukuoka, Japan.

We conducted a 2-year histologic and histometric evaluation of the tibial bone-titanium (Ti) implant interface in male rats. Thirty male 6-week-old rats were used in this study. They were divided into two groups: 15 for day 28 and 15 for day 730. Microscopic observation at day 28 revealed that the newly formed bone around the implant almost surrounded the implant, but fibroblastlike cells were interposed in some histologic sections. At day 730, in contrast, such cells were rarely seen, and the bone around the implant presented a lamellar structure. Transmission electron microscopic observation at day 28 disclosed mature or poorly mineralized bone near the implant; however, an electron-dense amorphous zone about 50 nm in thickness was interposed between the bone and Ti. In places slender cells were interposed between the bone and Ti. The amorphous zone was also observed at the cell-Ti interface. At day 730, a poorly mineralized layer remained in some areas between the mature bone and the titanium, and the interposed amorphous zone was still observed. Occasionally, a 200-nm-thick layer, thought to be cell remnant, was seen. As calculated in an image-processing, system analysis, the percent bone contact and the thickness and area of the surrounding bone for the Ti implant at day 28 were 43.6%, 30.4 microns, and 0.10 mm2, respectively, and those at day 730 were 89.9%, 53.5 microns, and 0.19 mm2, respectively. In summary, although the passage of time may affect bone maturity, interfacial cells remain at the bone-Ti interface as a uniform layer together with unmineralized bone.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008297 Male Males
D008854 Microscopy, Electron Microscopy using an electron beam, instead of light, to visualize the sample, thereby allowing much greater magnification. The interactions of ELECTRONS with specimens are used to provide information about the fine structure of that specimen. In TRANSMISSION ELECTRON MICROSCOPY the reactions of the electrons that are transmitted through the specimen are imaged. In SCANNING ELECTRON MICROSCOPY an electron beam falls at a non-normal angle on the specimen and the image is derived from the reactions occurring above the plane of the specimen. Electron Microscopy
D002113 Calcification, Physiologic Process by which organic tissue becomes hardened by the physiologic deposit of calcium salts. Bone Mineralization,Calcification, Physiological,Physiologic Calcification,Mineralization, Bone,Physiological Calcification
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D013977 Tibia The second longest bone of the skeleton. It is located on the medial side of the lower leg, articulating with the FIBULA laterally, the TALUS distally, and the FEMUR proximally. Tibias
D014025 Titanium A dark-gray, metallic element of widespread distribution but occurring in small amounts with atomic number, 22, atomic weight, 47.867 and symbol, Ti; specific gravity, 4.5; used for fixation of fractures.
D017208 Rats, Wistar A strain of albino rat developed at the Wistar Institute that has spread widely at other institutions. This has markedly diluted the original strain. Wistar Rat,Rat, Wistar,Wistar Rats
D051381 Rats The common name for the genus Rattus. Rattus,Rats, Laboratory,Rats, Norway,Rattus norvegicus,Laboratory Rat,Laboratory Rats,Norway Rat,Norway Rats,Rat,Rat, Laboratory,Rat, Norway,norvegicus, Rattus

Related Publications

F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
February 2012, Journal of the Royal Society, Interface,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
December 1985, The Physiologist,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
January 2008, European journal of histochemistry : EJH,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
June 1992, Microscopy research and technique,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
January 2001, Journal of microscopy,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
April 2018, Bioscience reports,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
July 1991, Physical review. B, Condensed matter,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
January 1978, Ultramicroscopy,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
February 2010, Journal of oral rehabilitation,
F Takeshita, and Y Ayukawa, and S Iyama, and K Murai, and T Suetsugu
April 2002, Journal of microscopy,
Copied contents to your clipboard!