Revision total knee arthroplasty with a cemented posterior-stabilized or constrained condylar prosthesis: a minimum 3-year and average 5-year follow-up study. 1997

C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
Department of Orthopaedics, University of Utah School of Medicine, Salt Lake City 84132, USA.

The results of 57 revision total knee arthroplasties performed for aseptic failure between 1984 and 1992 with a cemented posterior-stabilized or constrained condylar prosthesis were reviewed at follow-up examinations at a minimum of 36 and an average of 62 months (range, 36-120 months). The reason for revision was aseptic loosening of 1 or both components in 32 knees (56%), instability in 16 knees (28%), polyethylene wear and osteolysis in 4 knees (7%), supracondylar femur fracture in 2 knees (4%), and a failed allograft, pain, and arthrofibrosis in 1 knee each (5% total). The average age of the patients at the time of the revision was 74 years (range, 38-90), and the original diagnosis for the majority of patients was osteoarthritis (74%). All of the revision prostheses were cemented posterior stabilized or constrained condylar-type implants. Bone deficiencies were grafted with cancellous allograft in contained defects and cortical allograft in noncontained defects. Five knees were reconstructed with allograft-prosthesis composites. The average modified Hospital for Special Surgery knee score improved from 49 to 82 (100 points possible) at final follow-up evaluation (P < 0.001). Seventy-nine percent of knees were graded as good or excellent. Kaplan-Meier survivorship analysis predicted 94%+/-6.2% survival at 40 months and 75%+/-25% at 99 months. There were 4 clinical failures, 3 of which were related to residual instability in patients with a posterior-stabilized prosthesis. Complications (3 knees) were exclusively related to the extensor mechanism. Radiographically, overall knee alignment improved from 0.3 degrees varus to 3.0 degrees valgus. Fifty-six percent of tibial components were placed in slight varus alignment. Radiolucent lines occurred in 33% of knees, but there were no complete or progressive radiolucencies. Radiolucent lines were more prevalent adjacent to press-fit intramedullary femoral stems compared with cemented stems (P < .02), but the difference did not correlate with clinical or radiographic failure. The median bone defect score, as proposed by the Knee Society Committee on Bone Defects, was significantly greater in knees that were revisions of a failed cemented total knee arthroplasty compared with revision of a failed cementless total knee arthroplasty (P = .02) but was not correlated with clinical or radiographic outcome (P > .05).

UI MeSH Term Description Entries
D007593 Joint Instability Lack of stability of a joint or joint prosthesis. Hypermobility, Joint,Instability, Joint,Laxity, Joint,Hypermobilities, Joint,Instabilities, Joint,Joint Hypermobilities,Joint Hypermobility,Joint Instabilities,Joint Laxities,Joint Laxity,Laxities, Joint
D007720 Knee Prosthesis Replacement for a knee joint. Knee Prostheses,Prostheses, Knee,Prosthesis, Knee
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011474 Prosthesis Design The plan and delineation of prostheses in general or a specific prosthesis. Design, Prosthesis,Designs, Prosthesis,Prosthesis Designs
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D011859 Radiography Examination of any part of the body for diagnostic purposes by means of X-RAYS or GAMMA RAYS, recording the image on a sensitized surface (such as photographic film). Radiology, Diagnostic X-Ray,Roentgenography,X-Ray, Diagnostic,Diagnostic X-Ray,Diagnostic X-Ray Radiology,X-Ray Radiology, Diagnostic,Diagnostic X Ray,Diagnostic X Ray Radiology,Diagnostic X-Rays,Radiology, Diagnostic X Ray,X Ray Radiology, Diagnostic,X Ray, Diagnostic,X-Rays, Diagnostic
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D001843 Bone Cements Adhesives used to fix prosthetic devices to bones and to cement bone to bone in difficult fractures. Synthetic resins are commonly used as cements. A mixture of monocalcium phosphate, monohydrate, alpha-tricalcium phosphate, and calcium carbonate with a sodium phosphate solution is also a useful bone paste. Bone Cement,Bone Glues,Bone Pastes,Bone Glue,Bone Paste,Cement, Bone,Cements, Bone,Glue, Bone,Glues, Bone,Paste, Bone,Pastes, Bone
D005260 Female Females

Related Publications

C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
June 2010, Clinics in orthopedic surgery,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
June 1998, The Journal of arthroplasty,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
August 2023, Clinics in orthopedic surgery,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
December 2017, Knee surgery & related research,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
February 2018, The journal of knee surgery,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
April 2013, The Journal of arthroplasty,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
March 2013, Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
May 2024, International orthopaedics,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
August 1992, Clinical orthopaedics and related research,
C L Peters, and R Hennessey, and R M Barden, and J O Galante, and A G Rosenberg
August 2020, The Journal of arthroplasty,
Copied contents to your clipboard!