Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation. 1998

J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
Department of Radiotherapy-Oncologic Center, Free University of Brussels, Jette, Belgium.

OBJECTIVE To analyze setup errors and the feasibility of their on-line correction using electronic portal imaging in the irradiation of lung tumors. METHODS Sixteen patients with lung cancer were irradiated through opposed anteroposterior fields. Localization images of anteroposterior fields were recorded with an electronic portal imaging device (EPID). Using an in-house developed algorithm for on-line comparison of portal images setup errors were measured and a correction of table position was performed with a remote couch control prior to treatment. In addition, residual errors were measured on the EPID verification image. Global and individual mean and standard deviation of setup errors were calculated and compared. The feasibility of the procedure was assessed measuring intra- and interobserver variability, influence of organ movement, reproducibility of error measurement, the extra time fraction needed for measuring and adjusting and the fraction of dose needed for imaging. RESULTS In two setups the procedure could not be finished normally due to problems inherent to the procedure. The reproducibility, intraobserver variability, and influence of organ movements were each described by a distribution with a mean value less than or equal to 1 mm and a standard deviation (SD) of less than 1.5 mm. The interobserver variability showed to be a little bit larger (mean: 0.3 mm, SD: 1.7 mm). The mean time to perform the irradiation of the anteroposterior field was 4 +/- 1 min. The mean time for the measurement and correction procedure approximated 2.5 min. The mean extra time fraction was 65 +/- 24% (1 SD) with more than half of this coming from the error measurement. The dose needed for generation of EPID images was 5.9 +/- 1.4% of total treatment dose. The mean and SD of setup errors were, respectively, 0.1 and 4.5 mm for longitudinal and -2.0 and 5.7 mm for transversal errors. Of 196 measured translational errors 120 (61%) exceeded the adjustment criteria. For individual patients systematic and random setup errors can be as high as, respectively, 15.8 and 7.5 mm. Mean residual error and SD were for longitudinal direction 0.08 and 1.2 mm and for transversal direction -0.9 and 1.0 mm (pooled data). For individuals, the mean residual errors were smaller than 1 mm, with a typical SD per patient of less than 2 mm. CONCLUSIONS Setup errors in thoracic radiation therapy are clinically important. On-line correction can be performed accurately with an objective measurement tool, although this prolongs the irradiation procedure for one field with 65%.

UI MeSH Term Description Entries
D008175 Lung Neoplasms Tumors or cancer of the LUNG. Cancer of Lung,Lung Cancer,Pulmonary Cancer,Pulmonary Neoplasms,Cancer of the Lung,Neoplasms, Lung,Neoplasms, Pulmonary,Cancer, Lung,Cancer, Pulmonary,Cancers, Lung,Cancers, Pulmonary,Lung Cancers,Lung Neoplasm,Neoplasm, Lung,Neoplasm, Pulmonary,Pulmonary Cancers,Pulmonary Neoplasm
D011880 Radiotherapy Planning, Computer-Assisted Computer-assisted mathematical calculations of beam angles, intensities of radiation, and duration of irradiation in radiotherapy. Computer-Assisted Radiotherapy Planning,Dosimetry Calculations, Computer-Assisted,Planning, Computer-Assisted Radiotherapy,Calculation, Computer-Assisted Dosimetry,Calculations, Computer-Assisted Dosimetry,Computer Assisted Radiotherapy Planning,Computer-Assisted Dosimetry Calculation,Computer-Assisted Dosimetry Calculations,Dosimetry Calculation, Computer-Assisted,Dosimetry Calculations, Computer Assisted,Planning, Computer Assisted Radiotherapy,Radiotherapy Planning, Computer Assisted
D002289 Carcinoma, Non-Small-Cell Lung A heterogeneous aggregate of at least three distinct histological types of lung cancer, including SQUAMOUS CELL CARCINOMA; ADENOCARCINOMA; and LARGE CELL CARCINOMA. They are dealt with collectively because of their shared treatment strategy. Carcinoma, Non-Small Cell Lung,Non-Small Cell Lung Cancer,Non-Small Cell Lung Carcinoma,Non-Small-Cell Lung Carcinoma,Nonsmall Cell Lung Cancer,Carcinoma, Non Small Cell Lung,Carcinomas, Non-Small-Cell Lung,Lung Carcinoma, Non-Small-Cell,Lung Carcinomas, Non-Small-Cell,Non Small Cell Lung Carcinoma,Non-Small-Cell Lung Carcinomas
D005240 Feasibility Studies Studies to determine the advantages or disadvantages, practicability, or capability of accomplishing a projected plan, study, or project. Feasibility Study,Studies, Feasibility,Study, Feasibility
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015588 Observer Variation The failure by the observer to measure or identify a phenomenon accurately, which results in an error. Sources for this may be due to the observer's missing an abnormality, or to faulty technique resulting in incorrect test measurement, or to misinterpretation of the data. Two varieties are inter-observer variation (the amount observers vary from one another when reporting on the same material) and intra-observer variation (the amount one observer varies between observations when reporting more than once on the same material). Bias, Observer,Interobserver Variation,Intraobserver Variation,Observer Bias,Inter-Observer Variability,Inter-Observer Variation,Interobserver Variability,Intra-Observer Variability,Intra-Observer Variation,Intraobserver Variability,Inter Observer Variability,Inter Observer Variation,Inter-Observer Variabilities,Inter-Observer Variations,Interobserver Variabilities,Interobserver Variations,Intra Observer Variability,Intra Observer Variation,Intra-Observer Variabilities,Intra-Observer Variations,Intraobserver Variabilities,Intraobserver Variations,Observer Variations,Variabilities, Inter-Observer,Variabilities, Interobserver,Variabilities, Intra-Observer,Variabilities, Intraobserver,Variability, Inter-Observer,Variability, Interobserver,Variability, Intra-Observer,Variability, Intraobserver,Variation, Inter-Observer,Variation, Interobserver,Variation, Intra-Observer,Variation, Intraobserver,Variation, Observer,Variations, Inter-Observer,Variations, Interobserver,Variations, Intra-Observer,Variations, Intraobserver,Variations, Observer

Related Publications

J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
June 2000, International journal of radiation oncology, biology, physics,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
December 2023, European review for medical and pharmacological sciences,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
February 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
March 2001, International journal of radiation oncology, biology, physics,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
June 1991, Radiology,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
July 2021, Journal of applied clinical medical physics,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
November 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
March 1996, International journal of radiation oncology, biology, physics,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
January 2007, International journal of biomedical imaging,
J Van de Steene, and F Van den Heuvel, and A Bel, and D Verellen, and J De Mey, and M Noppen, and M De Beukeleer, and G Storme
April 2008, Journal of medical physics,
Copied contents to your clipboard!