Hemodynamic benefits of right ventricular outflow tract pacing: comparison with right ventricular apex pacing. 1998

C C de Cock, and A Meyer, and O Kamp, and C A Visser
Department of Cardiology, Academic Hospital VU, Amsterdam, The Netherlands.

To assess optimal hemodynamics in relation to stimulation site during right ventricular pacing, 17 consecutive patients who underwent cardiac catheterization were studied. In all patients, right ventricular apex and right ventricular outflow tract stimulation was performed at 85, 100, and 120 beats/min. Cardiac index at both pacing sites was compared using the left ventricular outflow tract continuous wave Doppler technique. Comparison of the two stimulation sites demonstrated that right ventricular outflow tract pacing resulted in a higher cardiac index at 85 beats/min (2.42 +/- 1.2 vs 2.04 +/- 1.0 L/min per m2, P < 0.002) at 100 beats/min (2.78 +/- 1.4 vs 2.35 +/- 1.1 L/min per m2, P < 0.001) and 120 beats/min (3.00 +/- 1.5 vs 2.61 +/- 0.9 L/min per m2, P < 0.001). From a total of 51 paired observations, 45 showed an increase in cardiac index during outflow tract pacing as compared to apex pacing. Right ventricular outflow tract pacing at 120 beats/min resulted in a lower cardiac index than right ventricular apex pacing in patients with significant coronary artery disease and/or impaired left ventricular function (ejection fraction < or = 50%), whereas right ventricular outflow tract pacing produced higher cardiac indices in the absence of these abnormalities. Right ventricular outflow tract pacing resulted in higher cardiac indices as compared to apex pacing in all other subgroups at all other pacing sites tested. It is concluded that stimulation of the right ventricular outflow tract offers a significant hemodynamic benefit during single chamber pacing as compared to conventional apex pacing, particularly in the absence of significant coronary artery disease and/or left ventricular dysfunction.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females
D006325 Heart Atria The chambers of the heart, to which the BLOOD returns from the circulation. Heart Atrium,Left Atrium,Right Atrium,Atria, Heart,Atrium, Heart,Atrium, Left,Atrium, Right
D006328 Cardiac Catheterization Procedures in which placement of CARDIAC CATHETERS is performed for therapeutic or diagnostic procedures. Catheterization, Cardiac,Catheterization, Heart,Heart Catheterization,Cardiac Catheterizations,Catheterizations, Cardiac,Catheterizations, Heart,Heart Catheterizations
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

C C de Cock, and A Meyer, and O Kamp, and C A Visser
October 2010, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
July 2003, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
November 2010, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
March 1998, Giornale italiano di cardiologia,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
December 2009, Clinical cardiology,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
May 1997, Pacing and clinical electrophysiology : PACE,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
June 2014, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
September 1997, Journal of cardiology,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
January 2005, Pacing and clinical electrophysiology : PACE,
C C de Cock, and A Meyer, and O Kamp, and C A Visser
September 2014, Polski merkuriusz lekarski : organ Polskiego Towarzystwa Lekarskiego,
Copied contents to your clipboard!