Doppler echocardiographic assessment of pulmonary blood flow in healthy newborns. 1998

V Gournay, and G Cambonie, and J C Rozé
Department of Neonatology, Hôpital Universitaire de Nantes, France.

The aim of this study was to determine interobserver variation in Doppler assessment of mean left pulmonary arterial flow velocity, and its normal values during the first 24h of life. The interobserver variation was determined by a Bland and Altman analysis of the values of mean velocity measured in 21 newborns by 2 observers. Then, normal values of mean velocity were measured in 15 newborns at 5, 10 and 15 min of life in the delivery room, and in 14 other newborns at 1, 2, 6, 12 and 24h of life in the nursery unit. The interobserver variation was found to be acceptable. Mean velocity had a few variations within the first 24 h, but remained consistently above 20 cm s(-1). In conclusion, mean velocity values below 20 cm(-1) suggest low pulmonary blood flow.

UI MeSH Term Description Entries
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D011651 Pulmonary Artery The short wide vessel arising from the conus arteriosus of the right ventricle and conveying unaerated blood to the lungs. Arteries, Pulmonary,Artery, Pulmonary,Pulmonary Arteries
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000704 Analysis of Variance A statistical technique that isolates and assesses the contributions of categorical independent variables to variation in the mean of a continuous dependent variable. ANOVA,Analysis, Variance,Variance Analysis,Analyses, Variance,Variance Analyses
D015150 Echocardiography, Doppler Measurement of intracardiac blood flow using an M-mode and/or two-dimensional (2-D) echocardiogram while simultaneously recording the spectrum of the audible Doppler signal (e.g., velocity, direction, amplitude, intensity, timing) reflected from the moving column of red blood cells. Doppler Echocardiography,Echocardiography, Continuous Doppler,Echocardiography, Two-Dimensional Doppler,2-D Doppler Echocardiography,2D Doppler Echocardiography,Continuous Doppler Echocardiography,Doppler Echocardiography, 2-D,Doppler Echocardiography, 2D,Doppler Echocardiography, Continuous,Doppler Echocardiography, Two-Dimensional,Echocardiography, 2-D Doppler,Echocardiography, 2D Doppler,Two-Dimensional Doppler Echocardiography,2 D Doppler Echocardiography,Doppler Echocardiography, 2 D,Doppler Echocardiography, Two Dimensional,Echocardiography, 2 D Doppler,Echocardiography, Two Dimensional Doppler,Two Dimensional Doppler Echocardiography
D015588 Observer Variation The failure by the observer to measure or identify a phenomenon accurately, which results in an error. Sources for this may be due to the observer's missing an abnormality, or to faulty technique resulting in incorrect test measurement, or to misinterpretation of the data. Two varieties are inter-observer variation (the amount observers vary from one another when reporting on the same material) and intra-observer variation (the amount one observer varies between observations when reporting more than once on the same material). Bias, Observer,Interobserver Variation,Intraobserver Variation,Observer Bias,Inter-Observer Variability,Inter-Observer Variation,Interobserver Variability,Intra-Observer Variability,Intra-Observer Variation,Intraobserver Variability,Inter Observer Variability,Inter Observer Variation,Inter-Observer Variabilities,Inter-Observer Variations,Interobserver Variabilities,Interobserver Variations,Intra Observer Variability,Intra Observer Variation,Intra-Observer Variabilities,Intra-Observer Variations,Intraobserver Variabilities,Intraobserver Variations,Observer Variations,Variabilities, Inter-Observer,Variabilities, Interobserver,Variabilities, Intra-Observer,Variabilities, Intraobserver,Variability, Inter-Observer,Variability, Interobserver,Variability, Intra-Observer,Variability, Intraobserver,Variation, Inter-Observer,Variation, Interobserver,Variation, Intra-Observer,Variation, Intraobserver,Variation, Observer,Variations, Inter-Observer,Variations, Interobserver,Variations, Intra-Observer,Variations, Intraobserver,Variations, Observer

Related Publications

V Gournay, and G Cambonie, and J C Rozé
January 1991, Terapevticheskii arkhiv,
V Gournay, and G Cambonie, and J C Rozé
September 2018, Journal of perinatal medicine,
V Gournay, and G Cambonie, and J C Rozé
March 1987, Journal of the American College of Cardiology,
V Gournay, and G Cambonie, and J C Rozé
January 1991, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
V Gournay, and G Cambonie, and J C Rozé
January 1995, European journal of pediatrics,
V Gournay, and G Cambonie, and J C Rozé
October 1996, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology,
V Gournay, and G Cambonie, and J C Rozé
June 2004, Cardiology in the young,
V Gournay, and G Cambonie, and J C Rozé
September 1993, International journal of cardiac imaging,
V Gournay, and G Cambonie, and J C Rozé
September 1993, Journal of the Formosan Medical Association = Taiwan yi zhi,
Copied contents to your clipboard!