Backfiltration (BKF) in single needle dialysis. 1997

M Giorgetti
Recanati Hospital, Italy.

Backfiltration (Bkf) is a potentially very dangerous phenomenon in haemodialysis, when chemical or biological contamination is present in the dialysate. It occurs when the dialysate pressure within the filter exceeds the pressure in the blood compartment, i.e. when Pbo < Pdi + pi o (where Pbo = the hydrostatic blood pressure at the filter outlet, Pdi = hydrostatic dialysate pressure at the filter inlet, pi o = oncotic pressure at filter outlet).

UI MeSH Term Description Entries
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009339 Needles Sharp instruments used for puncturing or suturing. Hypodermic Needles,Hypodermic Needle,Needle,Needle, Hypodermic,Needles, Hypodermic
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D005260 Female Females
D005374 Filtration A process of separating particulate matter from a fluid, such as air or a liquid, by passing the fluid carrier through a medium that will not pass the particulates. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Filtrations
D006435 Renal Dialysis Therapy for the insufficient cleansing of the BLOOD by the kidneys based on dialysis and including hemodialysis, PERITONEAL DIALYSIS, and HEMODIAFILTRATION. Dialysis, Extracorporeal,Dialysis, Renal,Extracorporeal Dialysis,Hemodialysis,Dialyses, Extracorporeal,Dialyses, Renal,Extracorporeal Dialyses,Hemodialyses,Renal Dialyses
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D006874 Hydrostatic Pressure The pressure due to the weight of fluid. Hydrostatic Pressures,Pressure, Hydrostatic,Pressures, Hydrostatic

Related Publications

M Giorgetti
March 1988, The International journal of artificial organs,
M Giorgetti
January 1982, Journal of medical engineering & technology,
M Giorgetti
September 1976, Nursing times,
M Giorgetti
December 1991, Nihon rinsho. Japanese journal of clinical medicine,
M Giorgetti
January 1972, Transactions - American Society for Artificial Internal Organs,
M Giorgetti
January 1977, Transactions - American Society for Artificial Internal Organs,
M Giorgetti
January 2011, Seminars in dialysis,
M Giorgetti
January 1973, Proceedings of the Clinical Dialysis and Transplant Forum,
M Giorgetti
October 1980, British medical journal,
M Giorgetti
January 1985, Transactions - American Society for Artificial Internal Organs,
Copied contents to your clipboard!