Bipolar implantable stimulator for long-term denervated-muscle experiments. 1998

R G Dennis
Institute of Gerontology, University of Michigan, Ann Arbor 48109-2007, USA.

A micropower bipolar implantable stimulator has been developed and tested for long-term (four weeks-six months) use in experiments involving the stimulation of denervated skeletal muscle. Implantable stimulators are typically operated from a single lithium battery at 3 V. After the first week of denervation, stimulation of denervated muscles of rats requires voltages in the range of 6-12 V. The stimulator described can deliver voltages up to 15 V, with variable pulsewidth, frequency and duty cycle. All stimulation parameters are set prior to implantation by selection of appropriate resistors and capacitors. Each primary failure mode for implantable stimulators is addressed. Long-term reliability rates in excess of 95% are achievable if the construction details are followed closely. Methods for battery power management, circuit component selection, electrode construction and encapsulation are described in detail. This device is not intended for use in humans.

UI MeSH Term Description Entries
D009121 Muscle Denervation The resection or removal of the innervation of a muscle or muscle tissue. Denervation, Muscle,Denervations, Muscle,Muscle Denervations
D004558 Electric Stimulation Use of electric potential or currents to elicit biological responses. Stimulation, Electric,Electrical Stimulation,Electric Stimulations,Electrical Stimulations,Stimulation, Electrical,Stimulations, Electric,Stimulations, Electrical
D004567 Electrodes, Implanted Surgically placed electric conductors through which ELECTRIC STIMULATION is delivered to or electrical activity is recorded from a specific point inside the body. Implantable Electrodes,Implantable Stimulation Electrodes,Implanted Electrodes,Implanted Stimulation Electrodes,Electrode, Implantable,Electrode, Implantable Stimulation,Electrode, Implanted,Electrode, Implanted Stimulation,Electrodes, Implantable,Electrodes, Implantable Stimulation,Electrodes, Implanted Stimulation,Implantable Electrode,Implantable Stimulation Electrode,Implanted Electrode,Implanted Stimulation Electrode,Stimulation Electrode, Implantable,Stimulation Electrode, Implanted,Stimulation Electrodes, Implantable,Stimulation Electrodes, Implanted
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor
D018482 Muscle, Skeletal A subtype of striated muscle, attached by TENDONS to the SKELETON. Skeletal muscles are innervated and their movement can be consciously controlled. They are also called voluntary muscles. Anterior Tibial Muscle,Gastrocnemius Muscle,Muscle, Voluntary,Plantaris Muscle,Skeletal Muscle,Soleus Muscle,Muscle, Anterior Tibial,Muscle, Gastrocnemius,Muscle, Plantaris,Muscle, Soleus,Muscles, Skeletal,Muscles, Voluntary,Skeletal Muscles,Tibial Muscle, Anterior,Voluntary Muscle,Voluntary Muscles

Related Publications

R G Dennis
January 1967, The Journal of physiology,
R G Dennis
July 2005, Medical & biological engineering & computing,
R G Dennis
March 2014, European journal of translational myology,
R G Dennis
March 2014, European journal of translational myology,
R G Dennis
July 1981, IEEE transactions on bio-medical engineering,
R G Dennis
May 1952, Archives of physical medicine and rehabilitation,
R G Dennis
September 1971, Biomedical engineering,
R G Dennis
November 1956, Archives of physical medicine and rehabilitation,
Copied contents to your clipboard!