The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo. 1998

A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
Department of Surgery, University of Texas Health Science Center, San Antonio, USA.

Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extracorporeal circuit have not been fully investigated regarding the quality of the pulsatility. In addition, most of these results have been gathered from adult patients, not from neonates and infants. We have designed and tested a neonate-infant pulsatile CPB system using 2 different types of 10 Fr aortic cannulas and membrane oxygenators in 3 kg piglets to evaluate the effects of these components on the pulsatile waveform produced by the system. In terms of the methods, Group 1 (Capiox 308 hollow-fiber membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 2]) was subjected to a 2 h period of normothermic pulsatile CPB with a pump flow rate of 150 ml/kg/min. Data were obtained at 5, 30, 60, 90, and 120 min of CPB. In Group 2 (Capiox 308 hollow-fiber membrane oxygenator and Elecath aortic cannula with a very long 10 Fr tip [n = 7]) and Group 3 (cobe VPCML Plus flat sheet membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 7]), the subjects' nasopharyngeal temperatures were reduced to 18 degrees C followed by 1 h of deep hypothermic circulatory arrest (DHCA) and then 40 min rewarming. Data were obtained during normothermic CPB in the pre- and post-DHCA periods. The criteria of pulsatility evaluations were based upon pulse pressure (between 30 and 40 mm Hg), aortic dp/dt (greater than 1000 mm Hg/s), and ejection time (less than 250 ms). The results showed that Group 1 produced flow which was significantly more pulsatile than that of the other 2 groups. Although the same oxygenator was used for Group 2, the quality of the pulsatile flow decreased when using a different aortic cannula. Group 3 did not meet any of the criteria for physiologic pulsatility. In conclusion these data suggest that in addition to a pulsatile pump, the aortic cannula and the membrane oxygenator must be chosen carefully to achieve physiologic pulsatile flow during CPB.

UI MeSH Term Description Entries
D007223 Infant A child between 1 and 23 months of age. Infants
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D010107 Oxygenators, Membrane Devices in which blood and oxygen are separated by a semipermeable membrane, generally of Teflon or polypropylene, across which gas exchange occurs. The membrane may be arranged as a series of parallel plates or as a number of hollow fibers; in the latter arrangement, the blood may flow inside the fibers, which are surrounded by gas, or the blood may flow outside the fibers and the gas inside the fibers. (Dorland, 28th ed) Membrane Oxygenator,Membrane Oxygenators,Oxygenator, Membrane
D011673 Pulsatile Flow Rhythmic, intermittent propagation of a fluid through a BLOOD VESSEL or piping system, in contrast to constant, smooth propagation, which produces laminar flow. Flow, Pulsating,Perfusion, Pulsatile,Flow, Pulsatile,Flows, Pulsatile,Flows, Pulsating,Perfusions, Pulsatile,Pulsatile Flows,Pulsatile Perfusion,Pulsatile Perfusions,Pulsating Flow,Pulsating Flows
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D002315 Cardiopulmonary Bypass Diversion of the flow of blood from the entrance of the right atrium directly to the aorta (or femoral artery) via an oxygenator thus bypassing both the heart and lungs. Heart-Lung Bypass,Bypass, Cardiopulmonary,Bypass, Heart-Lung,Bypasses, Cardiopulmonary,Bypasses, Heart-Lung,Cardiopulmonary Bypasses,Heart Lung Bypass,Heart-Lung Bypasses
D002404 Catheterization Use or insertion of a tubular device into a duct, blood vessel, hollow organ, or body cavity for injecting or withdrawing fluids for diagnostic or therapeutic purposes. It differs from INTUBATION in that the tube here is used to restore or maintain patency in obstructions. Cannulation,Cannulations,Catheterizations
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D000831 Animals, Newborn Refers to animals in the period of time just after birth. Animals, Neonatal,Animal, Neonatal,Animal, Newborn,Neonatal Animal,Neonatal Animals,Newborn Animal,Newborn Animals

Related Publications

A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
January 1993, ASAIO journal (American Society for Artificial Internal Organs : 1992),
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
January 1985, Life support systems : the journal of the European Society for Artificial Organs,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
September 1998, Perfusion,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
January 1999, ASAIO journal (American Society for Artificial Internal Organs : 1992),
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
July 2010, World journal for pediatric & congenital heart surgery,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
October 1996, The International journal of artificial organs,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
January 1981, Transactions - American Society for Artificial Internal Organs,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
May 1972, The American journal of cardiology,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
June 1986, Texas Heart Institute journal,
A Undar, and A J Lodge, and C W Daggett, and T M Runge, and R M Ungerleider, and J H Calhoon
December 1994, Artificial organs,
Copied contents to your clipboard!