Correction of partial volume effects in myocardial SPECT. 1998

B F Hutton, and A Osiecki
Department of Medical Physics, Westmead Hospital, Sydney, NSW, Australia. Brian.Hutton@imag.wsahs.nsw.gov.au

BACKGROUND Marked partial volume effects occur in myocardial single photon emission computed tomographic (SPECT) studies because of limited resolution in imaging the myocardial wall and contractile motion of the heart. Little work has been undertaken to develop correction techniques for SPECT except for efforts to improve the reconstructed resolution. Our purpose was to examine the extent of the problem and propose a correction method. RESULTS A potential correction method, developed initially for positron emission tomography, involved estimation of extravascular density by means of subtracting vascular density derived in a blood pool study from total density derived from a transmission study. Provided partial volume errors are the same for transmission and emission data, activity per gram of extravascular tissue can be obtained by means of dividing the perfusion regional data by extravascular density for the same region. Simulations were designed to assess the importance of partial volume errors and the use of extravascular density to correct the errors. Recovery coefficients for the myocardium were estimated by means of simulation of the beating heart on the basis of published values for ventricular dimensions. Resolution for transmission with a scanning line source system was compared with emission resolution. The effect of spillover on measured partial volume losses was assessed, and a method for matching spillover for emission and extravascular density was demonstrated. Correction for partial volume effects was demonstrated for a phantom with variable wall thickness. Significant variation in recovery coefficient was demonstrated between posterior and septal walls for individual patients independent of heart size. Filtering was necessary to account for the difference in transmission resolution measured in the axial direction. Spillover effects had a significant influence on the measured recovery for small objects; however, for a specific reconstruction algorithm and defined region size, correction was implemented to match the spillover effects for emission and extravascular density. Use of extravascular density for correction of partial volume loss, for ordered subsets expectation maximization reconstruction with compensation for resolution, was demonstrated to be accurate to within 10%. CONCLUSIONS The feasibility of correcting partial volume effects with extravascular density was demonstrated. Correction is effective provided care is taken to match both resolution and spillover for emission and extravascular density.

UI MeSH Term Description Entries
D006976 Hypertension, Pulmonary Increased VASCULAR RESISTANCE in the PULMONARY CIRCULATION, usually secondary to HEART DISEASES or LUNG DISEASES. Pulmonary Hypertension
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D009200 Myocardial Contraction Contractile activity of the MYOCARDIUM. Heart Contractility,Inotropism, Cardiac,Cardiac Inotropism,Cardiac Inotropisms,Contractilities, Heart,Contractility, Heart,Contraction, Myocardial,Contractions, Myocardial,Heart Contractilities,Inotropisms, Cardiac,Myocardial Contractions
D009202 Cardiomyopathies A group of diseases in which the dominant feature is the involvement of the CARDIAC MUSCLE itself. Cardiomyopathies are classified according to their predominant pathophysiological features (DILATED CARDIOMYOPATHY; HYPERTROPHIC CARDIOMYOPATHY; RESTRICTIVE CARDIOMYOPATHY) or their etiological/pathological factors (CARDIOMYOPATHY, ALCOHOLIC; ENDOCARDIAL FIBROELASTOSIS). Myocardial Disease,Myocardial Diseases,Myocardial Diseases, Primary,Myocardial Diseases, Secondary,Myocardiopathies,Primary Myocardial Disease,Cardiomyopathies, Primary,Cardiomyopathies, Secondary,Primary Myocardial Diseases,Secondary Myocardial Diseases,Cardiomyopathy,Cardiomyopathy, Primary,Cardiomyopathy, Secondary,Disease, Myocardial,Disease, Primary Myocardial,Disease, Secondary Myocardial,Diseases, Myocardial,Diseases, Primary Myocardial,Diseases, Secondary Myocardial,Myocardial Disease, Primary,Myocardial Disease, Secondary,Myocardiopathy,Primary Cardiomyopathies,Primary Cardiomyopathy,Secondary Cardiomyopathies,Secondary Cardiomyopathy,Secondary Myocardial Disease
D005240 Feasibility Studies Studies to determine the advantages or disadvantages, practicability, or capability of accomplishing a projected plan, study, or project. Feasibility Study,Studies, Feasibility,Study, Feasibility
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D015899 Tomography, Emission-Computed, Single-Photon A method of computed tomography that uses radionuclides which emit a single photon of a given energy. The camera is rotated 180 or 360 degrees around the patient to capture images at multiple positions along the arc. The computer is then used to reconstruct the transaxial, sagittal, and coronal images from the 3-dimensional distribution of radionuclides in the organ. The advantages of SPECT are that it can be used to observe biochemical and physiological processes as well as size and volume of the organ. The disadvantage is that, unlike positron-emission tomography where the positron-electron annihilation results in the emission of 2 photons at 180 degrees from each other, SPECT requires physical collimation to line up the photons, which results in the loss of many available photons and hence degrades the image. CAT Scan, Single-Photon Emission,CT Scan, Single-Photon Emission,Radionuclide Tomography, Single-Photon Emission-Computed,SPECT,Single-Photon Emission-Computed Tomography,Tomography, Single-Photon, Emission-Computed,Single-Photon Emission CT Scan,Single-Photon Emission Computer-Assisted Tomography,Single-Photon Emission Computerized Tomography,CAT Scan, Single Photon Emission,CT Scan, Single Photon Emission,Emission-Computed Tomography, Single-Photon,Radionuclide Tomography, Single Photon Emission Computed,Single Photon Emission CT Scan,Single Photon Emission Computed Tomography,Single Photon Emission Computer Assisted Tomography,Single Photon Emission Computerized Tomography,Tomography, Single-Photon Emission-Computed
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

B F Hutton, and A Osiecki
January 1997, Human brain mapping,
B F Hutton, and A Osiecki
August 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
B F Hutton, and A Osiecki
September 2016, Medical physics,
B F Hutton, and A Osiecki
April 2020, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
B F Hutton, and A Osiecki
November 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
B F Hutton, and A Osiecki
September 2015, Physics in medicine and biology,
B F Hutton, and A Osiecki
July 2004, European journal of nuclear medicine and molecular imaging,
B F Hutton, and A Osiecki
May 2017, Physics in medicine and biology,
Copied contents to your clipboard!