[Dual-chamber implantable automatic defibrillators. Experiences apropos of 16 cases]. 1998

P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
Service de cardiologie A, Hôpital cardiologique, Lille.

In view of the large number of inappropriate shocks observed in patients with implanted defibrillators, improved detection of ventricular arrhythmias has become a major objective. The addition of an atrial catheter has been proposed to improve discrimination between ventricular and non-ventricular arrhythmias. Besides this function, the additional catheter could be used for DDD pacing without risk of interaction between the pacemaker and defibrillator. The authors report their initial experience in 16 patients implanted with a DDD pacemaker. The indication was resuscitated sudden death (N = 5) or ventricular tachycardia (N = 11). The choice of a DDD defibrillator was justified by a bradycardia (N = 9), haemodynamic factors (N = 4) or supraventricular tachycardia (N = 3). The devices used were the Defender 9001 (ELA Medical SA, France, N = 3), the Ventak AV 1810 and the Ventak AV II DR 1821 (Guidant/CPI, Inc. USA, N = 11 and N = 2 respectively). There were three immediate complications. After 2 to 29 months' follow-up, 5 patients had received appropriate treatment by their devices. Five patients had inappropriate shocks : one patient received a shock triggered by electrical interference, two others had no active sensing algorithme when the shocks were delivered, and the other two had an activated algorithme with 1/1 conduction of a supraventricular arrhythmia. No recurrences were recorded after reprogramming the device. DDD or VDD pacing was permanent in 9 patients and intermittent in 3 others. Seven patients had dilated cardiomyopathy and severe cardiac failure and were clinically improved by dual chamber pacing. In many patients, candidates for a defibrillator, this new generation of devices has improved specificity of arrhythmia detection and cardiac pacing without risk of interaction. The authors propose a classification of the indications for a DDD defibrillator.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D012151 Resuscitation The restoration to life or consciousness of one apparently dead. (Dorland, 27th ed) Resuscitations
D001919 Bradycardia Cardiac arrhythmias that are characterized by excessively slow HEART RATE, usually below 50 beats per minute in human adults. They can be classified broadly into SINOATRIAL NODE dysfunction and ATRIOVENTRICULAR BLOCK. Bradyarrhythmia,Bradyarrhythmias,Bradycardias
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D002311 Cardiomyopathy, Dilated A form of CARDIAC MUSCLE disease that is characterized by ventricular dilation, VENTRICULAR DYSFUNCTION, and HEART FAILURE. Risk factors include SMOKING; ALCOHOL DRINKING; HYPERTENSION; INFECTION; PREGNANCY; and mutations in the LMNA gene encoding LAMIN TYPE A, a NUCLEAR LAMINA protein. Cardiomyopathy, Congestive,Congestive Cardiomyopathy,Dilated Cardiomyopathy,Cardiomyopathy, Dilated, 1a,Cardiomyopathy, Dilated, Autosomal Recessive,Cardiomyopathy, Dilated, CMD1A,Cardiomyopathy, Dilated, LMNA,Cardiomyopathy, Dilated, With Conduction Defect 1,Cardiomyopathy, Dilated, with Conduction Deffect1,Cardiomyopathy, Familial Idiopathic,Cardiomyopathy, Idiopathic Dilated,Cardiomyopathies, Congestive,Cardiomyopathies, Dilated,Cardiomyopathies, Familial Idiopathic,Cardiomyopathies, Idiopathic Dilated,Congestive Cardiomyopathies,Dilated Cardiomyopathies,Dilated Cardiomyopathies, Idiopathic,Dilated Cardiomyopathy, Idiopathic,Familial Idiopathic Cardiomyopathies,Familial Idiopathic Cardiomyopathy,Idiopathic Cardiomyopathies, Familial,Idiopathic Cardiomyopathy, Familial,Idiopathic Dilated Cardiomyopathies,Idiopathic Dilated Cardiomyopathy
D002404 Catheterization Use or insertion of a tubular device into a duct, blood vessel, hollow organ, or body cavity for injecting or withdrawing fluids for diagnostic or therapeutic purposes. It differs from INTUBATION in that the tube here is used to restore or maintain patency in obstructions. Cannulation,Cannulations,Catheterizations
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment

Related Publications

P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
April 2012, Archives of internal medicine,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
December 1996, Biomedizinische Technik. Biomedical engineering,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
July 1994, Archives des maladies du coeur et des vaisseaux,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
August 1988, British journal of hospital medicine,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
January 2003, Soins; la revue de reference infirmiere,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
March 1999, The American journal of cardiology,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
July 2003, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
August 2011, Journal of the American College of Cardiology,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
August 2002, Current treatment options in cardiovascular medicine,
P Le Franc, and D Klug, and D Lacroix, and C Kouakam, and M Jarwé, and S Kacet
January 1999, Annual review of biomedical engineering,
Copied contents to your clipboard!