[Measuring cyclosporine levels in whole blood in kidney transplantation]. 1998

P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
Departamento de Patologia Clínica, Faculdade de Ciências Médicas, UNICAMP, Campinas, SP.

BACKGROUND Cyclosporin A is a potent immunosuppressive drug effective in combatting rejection following organ transplantation. In na effort to replace a radioimmunoassay (RIA) for whole blood determination of cyclosporine (Cya) we compared RIA with fluorescence polarization immunoassay (FPIAm). METHODS 65 blood samples were analysed from kidney transplanted patients. The samples were collected into tubes containing EDTA as anticoagulant and analysed by RIA and FPIAm. RESULTS The statistical analysis revealed a difference between both methods (p < 0.05). The linear-regression comparison of Cya concentration measured by RIA and FPIAm showed the following relationship: Cya(FPIAm) = 1.06 x Cya(RIA) + 5.8 (r = 0.9817). CONCLUSIONS We conclude that FPIAm provides na alternative method for measuring cyclosporine in whole blood with the added advantages of being reasonably rapid, precise and easy to perform.

UI MeSH Term Description Entries
D007166 Immunosuppressive Agents Agents that suppress immune function by one of several mechanisms of action. Classical cytotoxic immunosuppressants act by inhibiting DNA synthesis. Others may act through activation of T-CELLS or by inhibiting the activation of HELPER CELLS. While immunosuppression has been brought about in the past primarily to prevent rejection of transplanted organs, new applications involving mediation of the effects of INTERLEUKINS and other CYTOKINES are emerging. Immunosuppressant,Immunosuppressive Agent,Immunosuppressants,Agent, Immunosuppressive,Agents, Immunosuppressive
D008297 Male Males
D011863 Radioimmunoassay Classic quantitative assay for detection of antigen-antibody reactions using a radioactively labeled substance (radioligand) either directly or indirectly to measure the binding of the unlabeled substance to a specific antibody or other receptor system. Non-immunogenic substances (e.g., haptens) can be measured if coupled to larger carrier proteins (e.g., bovine gamma-globulin or human serum albumin) capable of inducing antibody formation. Radioimmunoassays
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D016030 Kidney Transplantation The transference of a kidney from one human or animal to another. Grafting, Kidney,Renal Transplantation,Transplantation, Kidney,Transplantation, Renal,Kidney Grafting,Kidney Transplantations,Renal Transplantations,Transplantations, Kidney,Transplantations, Renal
D016231 Fluorescence Polarization Immunoassay Fluoroimmunoassay where detection of the hapten-antibody reaction is based on measurement of the increased polarization of fluorescence-labeled hapten when it is combined with antibody. The assay is very useful for the measurement of small haptenic antigens such as drugs at low concentrations. Immunoassay, Fluorescence Polarization,Polarization Fluoroimmunoassay,Fluorescence Polarization Immunoassays,Fluoroimmunoassay, Polarization,Fluoroimmunoassays, Polarization,Immunoassays, Fluorescence Polarization,Polarization Fluoroimmunoassays,Polarization Immunoassay, Fluorescence,Polarization Immunoassays, Fluorescence
D016572 Cyclosporine A cyclic undecapeptide from an extract of soil fungi. It is a powerful immunosupressant with a specific action on T-lymphocytes. It is used for the prophylaxis of graft rejection in organ and tissue transplantation. (From Martindale, The Extra Pharmacopoeia, 30th ed). Cyclosporin A,Ciclosporin,CsA-Neoral,CyA-NOF,Cyclosporin,Cyclosporine A,Neoral,OL 27-400,Sandimmun,Sandimmun Neoral,Sandimmune,CsA Neoral,CsANeoral,CyA NOF,OL 27 400,OL 27400

Related Publications

P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
August 1990, Transplantation proceedings,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
January 1998, Medicinski arhiv,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
February 1987, Transplantation proceedings,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
December 1994, Clinical biochemistry,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
July 1998, Transplantation,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
January 1992, Journal of clinical & laboratory immunology,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
November 1996, Transplantation,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
December 1983, Transplantation proceedings,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
October 1994, Transplantation proceedings,
P V Bottini, and F A Alves-Cunha, and M A Moda, and M I Souza, and C R Garlipp
November 1990, Clinical chemistry,
Copied contents to your clipboard!