Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. 1998

L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
Intensive Care Unit and Trauma Center, Hôpital Nord, Marseilles University Hospital System, Marseilles Medical School, France.

OBJECTIVE Many heat and moisture exchangers with filter (HMEF) have been developed. In-house data from companies provide some information about their performances; unfortunately, to our knowledge, no comparative evaluation in clinical conditions has been undertaken of these newer products. The aim of this study was to compare the efficiency of two HMEFs, one hydrophobic and one hygroscopic, on humidifying capacity and the rate of bronchial colonization and ventilator-associated pneumonia in ICU patients. METHODS Prospective, randomized study. METHODS ICU of a university hospital. METHODS All patients who required mechanical ventilation for > or = 24 h during the study period. METHODS On admission to the ICU, patients were randomly assigned to one of two groups. In one group, the patients were ventilated with a hygroscopic device (Humid-Vent Filter Light HMEF; Gibeck; Upplands Vaesby, Sweden). The condensation surface was made of paper (Microwell) impregnated with CaCl2. The filter membrane was made of polypropylene. In the other group, the patients were ventilated with a hydrophobic device (Pall BB100 HMEF). The condensation surface was made of a hydrophobic resin with a hydrophylic layer. The filter membrane was made of ceramic fibers. In both groups, HMEFs were changed daily. RESULTS Both groups of patients were similar for the tested characteristics, including parameters of mechanical ventilation. Sixty-six patients were ventilated for 11.7+/-11 days with the Humid-Vent Filter Light HMEF and 70 patients for 12.2+/-12 days with the Pall BB 100. Patients ventilated with the Humid-Vent Filter Light underwent 6.0+/-3.0 tracheal aspirations and 1.7+/-2.0 instillations per day, and those with the Pall BB 100, 6.0+/-3.0 and 1.6+/-2.0 per day, respectively (not significant [NS]). Abundance of tracheal secretions, presence of blood, and viscosity, evaluated by semiquantitative scales, were similar in both groups. No difference in the rate of atelectasis was observed between the two groups (7.5% and 7.1%, NS). One episode of tracheal tube occlusion was observed with the Humid-Vent Filter Light HMEF, and one with the other HMEF (NS). One patient in each group (NS) was switched to an active heated humidifier because of very tenacious bronchial secretions despite repeated instillations. Tracheal colonization was observed at a rate of 67% with the Humid-Vent Filter Light and 58% with the Pall BB 100 (NS). A small, but NS difference was observed in the rate of ventilator-associated pneumonia: Humid-Vent Filter Light, 32% (27.1 per 1000 ventilator days); and Pall BB 100, 37% (30.4 per 1000 ventilator days). Bacteria responsible for tracheal colonization and pneumonia were similar in both groups. Three patients in each group died from their nosocomial pneumonia. CONCLUSIONS Despite differences in their components, the two HMEFs tested achieved similar performances in terms of humidification and heating of inspired gases. Only one episode of endotracheal tube occlusion was detected and very few patients (one in each group) had to be switched to an active heated humidifier. No difference was observed either in the rate of tracheal colonization or of ventilator-associated pneumonia. These data show that the hygroscopic HME (Humid-Vent Filter Light) and the hydrophobic HME (Pall BB 100) are suited for use in ICU patients.

UI MeSH Term Description Entries
D007362 Intensive Care Units Hospital units providing continuous surveillance and care to acutely ill patients. ICU Intensive Care Units,Intensive Care Unit,Unit, Intensive Care
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D012122 Ventilators, Mechanical Mechanical devices used to produce or assist pulmonary ventilation. Mechanical Ventilator,Mechanical Ventilators,Respirators,Ventilators, Pulmonary,Pulmonary Ventilator,Pulmonary Ventilators,Ventilator, Pulmonary,Ventilators,Respirator,Ventilator,Ventilator, Mechanical
D003428 Cross Infection Any infection which a patient contracts in a health-care institution. Hospital Infections,Nosocomial Infections,Health Care Associated Infection,Health Care Associated Infections,Healthcare Associated Infections,Infection, Cross,Infections, Hospital,Infections, Nosocomial,Cross Infections,Healthcare Associated Infection,Hospital Infection,Infection, Healthcare Associated,Infection, Hospital,Infection, Nosocomial,Infections, Cross,Infections, Healthcare Associated,Nosocomial Infection
D005260 Female Females
D006358 Hot Temperature Presence of warmth or heat or a temperature notably higher than an accustomed norm. Heat,Hot Temperatures,Temperature, Hot,Temperatures, Hot
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D006813 Humidity A measure of the amount of WATER VAPOR in the air. Humidities

Related Publications

L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
February 1985, Anaesthesia,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
September 2000, Infection control and hospital epidemiology,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
May 1994, Perspectives in respiratory nursing : a publication of the Respiratory Nursing Society,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
March 1990, Critical care medicine,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
May 1999, Critical care medicine,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
May 2000, Critical care medicine,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
December 1980, Acta anaesthesiologica Scandinavica,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
October 1997, Critical care medicine,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
May 1999, Infection control and hospital epidemiology,
L Thomachot, and X Viviand, and S Arnaud, and C Boisson, and C D Martin
April 1995, American journal of respiratory and critical care medicine,
Copied contents to your clipboard!