Capillary zone electrophoresis at subzero temperatures. III. Operating conditions and separation efficiency. 1998

S Ma, and C Horváth
Department of Chemical Engineering, Mason Laboratory, Yale University, New Haven, CT 06520-8286, USA.

The advantages of carrying out capillary zone electrophoresis at subambient rather than ambient temperatures are examined. They include the possibility of using higher electric field strength and/or buffer concentration as well as wider capillary lumen without untoward effects of Joule heating on the separation. Furthermore, the separation efficiency is enhanced as molecular diffusivity decreases with temperature. A Beckman P/ACE unit with an auxiliary cooling system was used at temperatures down to -20 degrees C and, based on the dependence of axial temperature gradient on the capillary length and the temperature of the coolant, an average capillary temperature was defined. The day-to-day migration times of proteins were reproducible with an R.S.D. better than 2.3%. The improvements in the separation efficiency upon lowering the temperature from 40 to 1 degree C are illustrated by the electropherograms of four closely related peptides. Generally, the plate efficiency is enhanced at low temperatures and the analysis time is prolonged due to the increased viscosity. However, the current at a fixed electric field also decreases with temperature and the capillary can be shortened to speed up the analysis. With benzenesulfonic acids, the rate of the generation of theoretical plates was two- to three-times higher using a 27 cm long capillary at -15 degrees C than a 47 cm long capillary at 40 degrees C. By using a 180 microns instead of a 50 microns I.D. capillary for the separation of the four peptides, the sample loading could be increased about 15 times without loss of resolution. In the capillary zone electrophoresis of proteins, it was found that protein interactions with the capillary wall can be significantly reduced by increasing buffer concentration at low temperatures where salt mediated hydrophobic interactions are attenuated. This is illustrated by the separation of beta-lactoglobulins A and B in a raw fused-silica capillary using 400 mM sodium borate buffer, pH 8.4. The results suggest that at subambient or even subzero temperatures, the scope of CZE can be extended by several ways so that the benefits are great enough to justify the use of a cooling system and temperature control appropriate for psychroelectrophoresis with fused-silica capillaries.

UI MeSH Term Description Entries
D010455 Peptides Members of the class of compounds composed of AMINO ACIDS joined together by peptide bonds between adjacent amino acids into linear, branched or cyclical structures. OLIGOPEPTIDES are composed of approximately 2-12 amino acids. Polypeptides are composed of approximately 13 or more amino acids. PROTEINS are considered to be larger versions of peptides that can form into complex structures such as ENZYMES and RECEPTORS. Peptide,Polypeptide,Polypeptides
D011506 Proteins Linear POLYPEPTIDES that are synthesized on RIBOSOMES and may be further modified, crosslinked, cleaved, or assembled into complex proteins with several subunits. The specific sequence of AMINO ACIDS determines the shape the polypeptide will take, during PROTEIN FOLDING, and the function of the protein. Gene Products, Protein,Gene Proteins,Protein,Protein Gene Products,Proteins, Gene
D002021 Buffers A chemical system that functions to control the levels of specific ions in solution. When the level of hydrogen ion in solution is controlled the system is called a pH buffer. Buffer
D003080 Cold Temperature An absence of warmth or heat or a temperature notably below an accustomed norm. Cold,Cold Temperatures,Temperature, Cold,Temperatures, Cold
D019075 Electrophoresis, Capillary A highly-sensitive (in the picomolar range, which is 10,000-fold more sensitive than conventional electrophoresis) and efficient technique that allows separation of PROTEINS; NUCLEIC ACIDS; and CARBOHYDRATES. (Segen, Dictionary of Modern Medicine, 1992) Capillary Zone Electrophoresis,Capillary Electrophoreses,Capillary Electrophoresis,Capillary Zone Electrophoreses,Electrophoreses, Capillary,Electrophoreses, Capillary Zone,Electrophoresis, Capillary Zone,Zone Electrophoreses, Capillary,Zone Electrophoresis, Capillary

Related Publications

S Ma, and C Horváth
July 1978, Analytical biochemistry,
S Ma, and C Horváth
January 2001, Rapid communications in mass spectrometry : RCM,
S Ma, and C Horváth
July 2017, ACS applied materials & interfaces,
S Ma, and C Horváth
January 2003, Journal of capillary electrophoresis and microchip technology,
S Ma, and C Horváth
October 1989, Journal of chromatography,
S Ma, and C Horváth
January 1977, Advances in enzymology and related areas of molecular biology,
S Ma, and C Horváth
January 1994, Biomedical chromatography : BMC,
S Ma, and C Horváth
February 1993, Journal of chromatography,
S Ma, and C Horváth
October 1989, Journal of chromatography,
Copied contents to your clipboard!